Experiment on DC-fault Ride Through of MMC Using a Half-Voltage Clamp Submodule
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
High-voltage, direct current systems using modular multilevel converters (MMCs) could be widely used in bulky energy transmission. Dc-fault ride through, including fault clearance and converter restart, is an issue that MMC must deal with. Conventional MMC topologies with dc-fault ride through capability involve a relatively high-power semiconductor cost and converter loss, and experimental verification is insufficient. This paper presents an MMC topology that employs a half-voltage clamp submodule. The proposed topology utilizes the submodule capacitor voltages to eliminate the freewheeling effect of diodes actively and achieve fast fault clearance and converter restart. The proposed topology also entails low additional cost. A 20 kW/1000 V laboratory prototype is built. Experiments are conducted to investigate dc-fault clearance and converter restart and verify the dc-fault ride through capability of the proposed topology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and Operation of a Hybrid Modular Multilevel Converter
Zeng, R., Xu, L., Yao, L., & Williams, B. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2320822 · Cited by 455
Modular Multilevel Converter topologies with DC-Short circuit current limitation
Marquardt, R. (2011) · 8th International Conference on Power Electronics - ECCE Asia · doi:10.1109/icpe.2011.5944451 · Cited by 413 · cited 3×
“Although the loss and cost in CDSM are already lower than those in FBSM, the cost can be further reduced because the voltage stress of the additional protective IGBT and diode during a dc fault is still high.”
MethodModular Multilevel Converter Design for VSC HVDC Applications
Oates, C. (2015) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2014.2348611 · Cited by 135
An enhanced MMC topology with DC fault ride-through capability
Li, X., Liu, W., Song, Q., Rao, H., & Xu, S. (2013) · IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2013.6700152 · Cited by 92 · cited 2×
“3(a)], the sum voltage of D2 and D4 is negative [18].”
BackgroundSelf-citation
Cited by
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“the complexity and cost of the protection system [110].”
BackgroundRana, R. A., Patel, S. A., Muthusamy, A., Lee, C. W., & Kim, H.-J. (2019) · Electronics · doi:10.3390/electronics8111329 · Cited by 102
Protection Systems for DC Shipboard Microgrids
Bayati, N., & Savaghebi, M. (2021) · Energies · doi:10.3390/en14175319 · Cited by 21
Metadata
- Authors
- Li, X., Song, Q., Liu, W., Zhu, Z., & Xu, S.
- Venue
- IEEE Journal of Emerging and Selected Topics in Power Electronics
- Published
- 2018-09
- Volume
- 6
- Issue
- 3
- Pages
- 1273-1279
- ISSN
- 2168-6777 (ISSN-L)
- 2168-6785
- OpenAlex
- W2792621338
- Cited by
- 38
- References
- 4
- FWCI
- 2.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.