mmHRV: Contactless Heart Rate Variability Monitoring Using Millimeter-Wave Radio
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Heart rate variability (HRV), which measures the fluctuation of heartbeat intervals, has been considered as an important indicator for general health evaluation. To alleviate the user burden and explore the usability for long-term health monitoring, noncontact methods for HRV monitoring have drawn tremendous attention. In this article, we present mmHRV, the first contact-free multiuser HRV monitoring system using commercial millimeter-wave (mmWave) radio. The design of mmHRV consists of two key components. First, we develop a calibration-free target detector to identify each user’s location. Second, a heartbeat signal extractor is devised, which can optimize the decomposition of the phase of the channel information modulated by the chest movement and, thus, estimate the heartbeat signal. The exact time of heartbeats is estimated by finding the peak location of the heartbeat signal while the interbeat intervals (IBIs) can be further derived for evaluating the HRV metrics of each target. We evaluate the system performance and the impact of different settings, including the distance between human and the device, user orientation, incidental angle, and blockage. Experimental results show that mmHRV can measure the HRV accurately with a median IBI estimation error of 28 ms (with respect to 96.16% accuracy). In addition, the root-mean-square error (RMSE) measured in the nonline-of-sight (NLOS) scenarios is 31.71 ms based on the experiments with 11 participants. The performance of the multiuser scenario is slightly degraded compared with the single-user case; however, the median error of the 3-user case is within 52 ms for all three tested locations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Variational Mode Decomposition
Dragomiretskiy, K., & Zosso, D. (2014) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2013.2288675 · Cited by 9,184 · cited 1×
“(12) can be solved by alternatively updating uk(t) and ωk until convergence [50].”
BackgroundAn overview of heart rate variability metrics and norms
Shaffer, F., & Ginsberg, J. P. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00258 · Cited by 7,185 · cited 2×
“In mmHRV, we use the three most widely used metrics to evaluate the HRV [2].”
MethodHeart rate variability: A review
Rajendra Acharya, U., Paul Joseph, K., Kannathal, N., Lim, C. M., & Suri, J. S. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0119-0 · Cited by 2,820 · cited 1×
“, Inter-Beat Intervals (IBI), is an important indicator of the overall health status of an individual [1].”
BackgroundFundamentals of Radar Signal Processing
Richards, M. A. (2005) · Cited by 2,807
Anxiety Disorders are Associated with Reduced Heart Rate Variability: A Meta-Analysis
Chalmers, J. A., Quintana, D. S., Abbott, M. J.-A., & Kemp, A. H. (2014) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2014.00080 · Cited by 1,067
Smart Homes that Monitor Breathing and Heart Rate
Adib, F., Mao, H., Kabelac, Z., Katabi, D., & Miller, R. C. (2015) · Proceedings of the 33rd Annual ACM Conference on Human Factors in Computing Systems · doi:10.1145/2702123.2702200 · Cited by 916 · cited 2×
“While many existing works have validated the feasibility of vital sign monitoring using RF signal, most of them can only estimate the Respiration Rate (RR) [15]–[17] and the Heart Rate (HR) [18]–[22], from which one cannot obtain the HRV without the precise timing of each heartbeat.”
BackgroundEmotion recognition using wireless signals
Zhao, M., Adib, F., & Katabi, D. (2016) · Proceedings of the 22nd Annual International Conference on Mobile Computing and Networking · doi:10.1145/2973750.2973762 · Cited by 461 · cited 1×
“, acceleration) has been considered in [7], which is equivalent to a High-Pass Filter (HPF).”
MethodMillimeter wave propagation: spectrum management implications
Marcus, M., & Pattan, B. (2005) · IEEE Microwave Magazine · doi:10.1109/mmw.2005.1491267 · Cited by 422
Vital-sign monitoring and spatial tracking of multiple people using a contactless radar-based sensor
Mercuri, M., Lorato, I. R., Liu, Y.-H., Wieringa, F., Hoof, C. V., & Torfs, T. (2019) · Nature Electronics · doi:10.1038/s41928-019-0258-6 · Cited by 354 · cited 1×
“2, and it can be expressed as [20] ft = fc + B Tc t, (1)”
BackgroundVital signs monitoring of multiple people using a FMCW millimeter-wave sensor
Ahmad, A., Roh, J. C., Wang, D., & Dubey, A. (2018) · 2018 IEEE Radar Conference (RadarConf18) · doi:10.1109/radar.2018.8378778 · Cited by 313 · cited 7×
“The existing HR estimating systems usually take multiple samples in the time domain to achieve higher HR estimation accuracy [17]–[21], which equals to averaging the heartbeats over a certain time window.”
BackgroundInfluentialRemote measurement of cognitive stress via heart rate variability
McDuff, D., Gontarek, S., & Picard, R. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944243 · Cited by 308 · cited 1×
“Video-based: In the past decade, researches have been conducted using the video signal to estimate HRV [28]–[30].”
BackgroundChest wall motion during tidal breathing
De Groote, A., Wantier, M., Cheron, G., Estenne, M., & Paiva, M. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.5.1531 · Cited by 258 · cited 6×
“Note that the respiration movement ranges from 4−12mm with a frequency of 6− 30 Breaths Per Minute (BPM) [24] while the heartbeat movement ranges from 0.”
BackgroundInfluentialHu, W., Zhao, Z., Wang, Y., Zhang, H., & Lin, F. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2288319 · Cited by 247 · cited 2×
“A simple approach based on two Band-Pass Filters (BPFs) is employed for separating the respiration and the heartbeat signal in [26] [27], however, since undesired peaks caused by the interference (e.”
MethodMonitoring vital signs using millimeter wave
Yang, Z., Pathak, P. H., Zeng, Y., Liran, X., & Mohapatra, P. (2016) · Proceedings of the 17th ACM International Symposium on Mobile Ad Hoc Networking and Computing · doi:10.1145/2942358.2942381 · Cited by 183
Khan, F., & Cho, S. H. (2017) · Sensors · doi:10.3390/s17020290 · Cited by 166
Petrovic, V. L., Jankovic, M. M., Lupsic, A. V., Mihajlovic, V. R., & Popovic-Bozovic, J. S. (2019) · IEEE Access · doi:10.1109/access.2019.2921240 · Cited by 165 · cited 17×
“BPFB shows larger IBI errors with 40ms, 42ms, 43ms, 55ms correspondingly.”
MethodInfluentialSMARS: Sleep Monitoring via Ambient Radio Signals
Zhang, F., Wu, C., Wang, B., Wu, M. H., Bugos, D., Zhang, H., & Liu, K. J. R. (2019) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2019.2939791 · Cited by 150 · cited 1×
“While many existing works have validated the feasibility of vital sign monitoring using RF signal, most of them can only estimate the Respiration Rate (RR) [15]–[17] and the Heart Rate (HR) [18]–[22], from which one cannot obtain the HRV without the precise timing of each heartbeat.”
BackgroundSelf-citationViMo: Multiperson Vital Sign Monitoring Using Commodity Millimeter-Wave Radio
Wang, F., Zhang, F., Wu, C., Wang, B., & Liu, K. J. R. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.3004046 · Cited by 149 · cited 2×
“While many existing works have validated the feasibility of vital sign monitoring using RF signal, most of them can only estimate the Respiration Rate (RR) [15]–[17] and the Heart Rate (HR) [18]–[22], from which one cannot obtain the HRV without the precise timing of each heartbeat.”
BackgroundSelf-citationAcousticcardiogram: Monitoring Heartbeats using Acoustic Signals on Smart Devices
Qian, K., Wu, C., Xiao, F., Zheng, Y., Zhang, Y., Yang, Z., & Liu, Y. (2018) · IEEE Conference on Computer Communications (INFOCOM) · doi:10.1109/infocom.2018.8485978 · Cited by 142
Self-citationWiSpeed: A Statistical Electromagnetic Approach for Device-Free Indoor Speed Estimation
Zhang, F., Chen, C., Wang, B., & Liu, K. J. R. (2018) · IEEE Internet of Things Journal · doi:10.1109/jiot.2018.2826227 · Cited by 139 · cited 1×
“To this end, Radio Frequency (RF) based sensing has become one of the most promising candidates, because the presence of a human subject will affect the RF signal propagation [9]–[11], e.”
BackgroundSelf-citationTR-BREATH: Time-Reversal Breathing Rate Estimation and Detection
Chen, C., Han, Y., Chen, Y., Lai, H.-Q., Zhang, F., Wang, B., & Liu, K. J. R. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2699422 · Cited by 137
Self-citationRespiration and Heartbeat Rates Measurement Based on Autocorrelation Using IR-UWB Radar
Shen, H., Chen, X., Yang, Y., Sun, L. J., Cai, Z., Bai, L., Clancy, E. A., & Huang, X. (2018) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2018.2860015 · Cited by 124 · cited 1×
“Dedicated radars [31]–[39] and Ultra-Wideband (UWB) [40]– [42] have been used to measure the distance change between the chest and the device to estimate heart rate (HR).”
MethodUse of Heart Rate Variability in Monitoring Stress and Recovery in Judo Athletes
Morales, J., Álamo, J., García‐Massó, X., Buscà, B., López, J. L. G., Serra‐Añó, P., & González, L.-M. (2013) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000000328 · Cited by 123
The Promise of Radio Analytics: A Future Paradigm of Wireless Positioning, Tracking, and Sensing
Wang, B., Xu, Q., Chen, C., Zhang, F., & Liu, K. J. R. (2018) · IEEE Signal Processing Magazine · doi:10.1109/msp.2018.2806300 · Cited by 122
Self-citationRamachandran, G., & Singh, M. C. (1989) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441473 · Cited by 117 · cited 1×
“5 mm [51] with frequency of 50-120 BPM [21].”
BackgroundWiDetect: Robust Motion Detection with a Statistical Electromagnetic Model
Zhang, F., Wu, C., Wang, B., Lai, H.-Q., Han, Y., & Liu, K. J. R. (2019) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3351280 · Cited by 111
Self-citationSakamoto, T., Imasaka, R., Taki, H., Sato, T., Yoshioka, M., Inoue, K., Fukuda, T., & Sakai, H. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2470077 · Cited by 107 · cited 1×
“To achieve robust HRV estimation, a preliminary work [43] tries to eliminate the respiration effect by asking users to hold their breaths.”
BackgroundSurface Chest Motion Decomposition for Cardiovascular Monitoring
Shafiq, G., & Veluvolu, K. C. (2014) · Scientific Reports · doi:10.1038/srep05093 · Cited by 103 · cited 1×
“To avoid the direct contact with users’ skin, other wearable devices such as Inertial Measurement Units (IMUs) have been explored to measure the movements of the chest surfaces to determine the IBIs and then measure the HRV [8].”
BackgroundRespiration Tracking for People Counting and Recognition
Wang, F., Zhang, F., Wu, C., Wang, B., & Liu, K. J. R. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.2977254 · Cited by 95 · cited 1×
“, RF signals reflected from the human body will be modulated by the body movement such as the chest movement caused by respiration and heartbeat, vital information of the human subject can be unveiled by analyzing the channel propagation characteristics [11]–[14].”
BackgroundSelf-citationCianca, E., Sanctis, M. D., & Domenico, S. D. (2016) · IEEE Internet of Things Journal · doi:10.1109/jiot.2016.2563399 · Cited by 78
Suzuki, S. V., Matsui, T., Imuta, H., Uenoyama, M., Yura, H., Ishihara, M., & Kawakami, M. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0298-3 · Cited by 61
Video pulse rate variability analysis in stationary and motion conditions
Rodríguez, A., & Ramos-Castro, J. J. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0437-0 · Cited by 36 · cited 1×
“Video-based: In the past decade, researches have been conducted using the video signal to estimate HRV [28]–[30].”
BackgroundNguyen, N. T. P., Lyu, P.-Y., Lin, M. H., Chang, C., & Chang, S. (2019) · IEEE MTT-S International Microwave Biomedical Conference (IMBioC) · doi:10.1109/imbioc.2019.8777797 · Cited by 19 · cited 4×
“A simple approach based on two Band-Pass Filters (BPFs) is employed for separating the respiration and the heartbeat signal in [26] [27], however, since undesired peaks caused by the interference (e.”
BackgroundMethodInfluentialPulse rate variability analysis by video using face detection and tracking algorithms
Rodríguez, A., & Ramos-Castro, J. J. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319685 · Cited by 8
Metadata
- Authors
- Wang, F., Zeng, X., Wu, C., Wang, B., & Liu, K. J. R.
- Venue
- IEEE Internet of Things Journal
- Published
- 2021-11-15
- Volume
- 8
- Issue
- 22
- Pages
- 16623-16636
- ISSN
- 2327-4662 (ISSN-L)
- 2372-2541
- OpenAlex
- W3158844943
- Cited by
- 192
- References
- 34
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.