Electrothermally activated paraffin microactuators
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A new family of electrothermally activated microactuators that can provide both large displacements and forces, are simple to fabricate, and are easily integrated with a large variety of microelectronic and microfluidic components are presented. The actuators use the high volumetric expansion of a sealed, surface micromachined patch of paraffin heated near its melting point to deform a sealing diaphragm. Two types of actuators have been fabricated using a simple three mask fabrication process. The first device structure consists of a 9 /spl mu/m thick circularly patterned paraffin layer ranging in diameter from 400 to 800 /spl mu/m all covered with a 4-/spl mu/m-thick metallized p-xylylene sealing diaphragm. All fabricated devices produced a 2.7-/spl mu/m-peak center deflection, consistent with a simple first order theory. The second actuator structure uses a constrained volume reservoir that magnifies the diaphragm deflection producing consistently 3.2 /spl mu/m center diaphragm deflection with a 3-/spl mu/m-thick paraffin actuation layer. Microactuators were constructed on both glass and silicon substrates. The actuators fabricated on glass substrates used between 50-200 mW of electrical power with response times ranging between 30-50 ms. The response time for silicon devices was much faster (3-5 ms) at the expense of a larger electrical power (500-2000 mW).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal conductivity of polymers
Choy, C. L. (1977) · Polymer · doi:10.1016/0032-3861(77)90002-7 · Cited by 483
Cited by
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Soft material for soft actuators
Miriyev, A., Stack, K., & Lipson, H. (2017) · Nature Communications · doi:10.1038/s41467-017-00685-3 · Cited by 861
Lima, M. D., Li, N., Jung de Andrade, M., Fang, S., Oh, J., Spinks, G. M., Kozlov, M. E., Haines, C. S., Suh, D., Foroughi, J., et al. (2012) · Science · doi:10.1126/science.1226762 · Cited by 724
MEMS actuators and sensors: observations on their performance and selection for purpose
Bell, D. J., Lu, T. J., Fleck, N. A., & Spearing, S. M. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/7/022 · Cited by 399
Pneumatic and hydraulic microactuators: a review
De Volder, M., & Reynaerts, D. (2010) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/4/043001 · Cited by 278
Metadata
- Authors
- Carlen, E. T., & Mastrangelo, C. H.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2002-06
- Volume
- 11
- Issue
- 3
- Pages
- 165-174
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2129780782
- Cited by
- 99
- References
- 1
- FWCI
- 3.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.