Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 251

The DOI matches its Crossref record.

Microfabricated Implantable Parylene-Based Wireless Passive Intraocular Pressure Sensors

Open access
Po-Jui Chen, Rodger, D.C., Saati, S., Humayun, M.S., Yu-Chong Tai·2008·Journal of Microelectromechanical Systems

Abstract

This paper presents an implantable parylene-based wireless pressure sensor for biomedical pressure sensing applications specifically designed for continuous intraocular pressure (IOP) monitoring in glaucoma patients. It has an electricalLCtank resonant circuit formed by an integrated capacitor and an inductor coil to facilitate passive wireless sensing using an external interrogating coil connected to a readout unit. Two surface-micromachined sensor designs incorporating variable capacitor and variable capacitor/inductor resonant circuits have been implemented to realize the pressure-sensitive components. The sensor is monolithically microfabricated by exploiting parylene as a biocompatible structural material in a suitable form factor for minimally invasive intraocular implantation. Pressure responses of the microsensor have been characterized to demonstrate its high pressure sensitivity ( > 7000 ppm/mmHg) in both sensor designs, which confirms the feasibility of pressure sensing with smaller than 1 mmHg of resolution for practical biomedical applications. A six-month animal study verifies theinvivobioefficacy and biostability of the implant in the intraocular environment with no surgical or postoperative complications. Preliminaryexvivoexperimental results verify the IOP sensing feasibility of such device. This sensor will ultimately be implanted at the pars plana or on the iris of the eye to fulfill continuous, convenient, direct, and faithful IOP monitoring.[2008-0111].

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jmems.2008.2004945

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 251

Metadata

Authors
Chen, P.-J., Rodger, D. C., Saati, S., Humayun, M. S., & Tai, Y.-C.
Venue
Journal of Microelectromechanical Systems
Published
2008-12
Volume
17
Issue
6
Pages
1342-1351
ISSN
  • 1057-7157 (ISSN-L)
  • 1941-0158
OpenAlex
W2129444923
Cited by
251
References
0
FWCI
7.47
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microfabricated Implantable Parylene-Based Wireless Passive Intraocular Pressure Sensors. https://app.cochat.ai/papers/10.1109/jmems.2008.2004945
The paper
Chen, P.-J., Rodger, D. C., Saati, S., Humayun, M. S., & Tai, Y.-C. (2008). Microfabricated Implantable Parylene-Based Wireless Passive Intraocular Pressure Sensors. Journal of Microelectromechanical Systems. https://doi.org/10.1109/jmems.2008.2004945

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.