Online Fault Detection and Diagnosis in Photovoltaic Systems Using Wavelet Packets
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The nonlinear characteristics of a photovoltaic (PV) array, maximum power point tracking of the PV inverter, presence of blocking diodes, and lower irradiation prevent the conventional protection devices to trip under certain faults and lead to reduced system efficiency and fire hazards. Moreover, the PV characteristics under certain partial shading conditions are similar to that under fault conditions. Hence, it is imperative to detect faults and differentiate faults from the partial shading condition to avoid false tripping of the system. This paper proposes a simple fault detection method using the available data of array voltage and current by means of wavelet packets. The proposed scheme is simulated using MATLAB/Simulink and is experimentally tested on a 1.6-kW 4 × 4 PV array to validate its performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Renewables 2015 Global Status Report
Raturi, A. (2015) · Cited by 1,098
Magnago, F. H., & Abur, A. (1998) · IEEE Transactions on Power Delivery · doi:10.1109/61.714808 · Cited by 616
Zhao, Y., Ball, R., Mosesian, J., de Palma, J.-F., & Lehman, B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2364203 · Cited by 331 · cited 1×
“To overcome the requirement of a large training data under fault conditions, a graph-based semisupervised learning method is proposed in [17].”
MethodLine–Line Fault Analysis and Protection Challenges in Solar Photovoltaic Arrays
Zhao, Y., De Palma, J.-F., Mosesian, J., Lyons, R., & Lehman, B. (2013) · Industrial Electronics, IEEE Transactions on · doi:10.1109/tie.2012.2205355 · Cited by 300 · cited 2×
“The LG fault and open-circuit faults are special cases of the LL fault [2], [19], and the severity of an LL fault depends upon the percentage mismatch.”
BackgroundDecision tree-based fault detection and classification in solar photovoltaic arrays
Zhao, Y., Yang, L., Lehman, B., de Palma, J.-F., Mosesian, J., & Lyons, R. (2012) · 2012 Twenty-Seventh Annual IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2012.6165803 · Cited by 268 · cited 1×
“In [16], a decision-tree-based algorithm is proposed to detect and classify the faults.”
BackgroundControlling of artificial neural network for fault diagnosis of photovoltaic array
Syafaruddin, Karatepe, E., & Hiyama, T. (2011) · 2011 16th International Conference on Intelligent System Applications to Power Systems · doi:10.1109/isap.2011.6082219 · Cited by 159 · cited 1×
“In another method, the voltage across each module is estimated by using a three-layer neural network [18] to detect and locate the short-circuit faults.”
MethodSmart Fault Location for Smart Grid Operation Using RTUs and Computational Intelligence Techniques
Reddy, M. J. B., Rajesh, D. V., Pathirikkat, G., & Mohanta, D. K. (2014) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2303833 · Cited by 97 · cited 1×
“Wavelets techniques are particularly suitable in analyzing the transient characteristics of the faults or any other type of disturbance that contains high-frequency components over a short duration of time [11], [20]–[23].”
BackgroundSelf-citationFault finding in a 1 MW photovoltaic plant by reflectometry
Schirone, L., Califano, F. P., Moschella, U., & Rocca, U. (2002) · World Conference on Photovoltaic Energy Conversion · doi:10.1109/wcpec.1994.520093 · Cited by 61 · cited 1×
“and degradation (increase in the series resistance) using the timedomain characteristics of the reflected voltage waveform [12], [13].”
MethodDesigning Fault-Tolerant Photovoltaic Systems
Lin, X., Wang, Y., Pedram, M., Kim, J., & Chang, N. (2013) · IEEE Design and Test · doi:10.1109/mdat.2013.2288252 · Cited by 35 · cited 1×
“In [10], if the power loss is more than a threshold value, a reconfiguration technique is used to identify and bypass the defective module.”
MethodA Method to Detect Photovoltaic Array Faults and Partial Shading in PV Systems
Hariharan, R., Chakkarapani, M., Ilango, G. S., & Nagamani, C. (2016) · IEEE Journal of Photovoltaics · doi:10.1109/jphotov.2016.2581478 · cited 2×
“The LG fault and open-circuit faults are special cases of the LL fault [2], [19], and the severity of an LL fault depends upon the percentage mismatch.”
BackgroundMethodSelf-citation
Cited by
Chen, Z., Chen, Y., Wu, L., Cheng, S., & Lin, P. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2019.111793 · Cited by 347
Chen, Z., Han, F., Wu, L., Yu, J., Cheng, S., Lin, P., & Chen, H. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.10.040 · Cited by 320
A Novel Convolutional Neural Network-Based Approach for Fault Classification in Photovoltaic Arrays
Aziz, F., Ul Haq, A., Ahmad, S., Mahmoud, Y., Jalal, M., & Ali, U. (2020) · IEEE Access · doi:10.1109/access.2020.2977116 · Cited by 254
Lu, X., Lin, P., Cheng, S., Lin, Y., Chen, Z., Wu, L., & Zheng, Q. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2019.06.062 · Cited by 177
Ali, Z., Terriche, Y., Hoang, L. Q. N., Abbas, S. Z., Hassan, M. A., Sadiq, M., Su, C.-L., & Guerrero, J. M. (2021) · IEEE Access · doi:10.1109/access.2021.3112383 · Cited by 104
Tao, Y., Yu, T., & Yang, J. (2024) · Sensors · doi:10.3390/s25010136 · Cited by 26
Metadata
- Authors
- Kumar, B. P., Ilango, G. S., Reddy, M. J. B., & Chilakapati, N.
- Venue
- IEEE Journal of Photovoltaics
- Published
- 2018-01
- Volume
- 8
- Issue
- 1
- Pages
- 257-265
- ISSN
- 2156-3381 (ISSN-L)
- 2156-3403
- OpenAlex
- W2772601414
- Cited by
- 161
- References
- 11
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.