The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Integration Issues of Distributed Generation in Distribution Grids
Abstract
In today's distribution grids the number of distributed generation (DG) units is increasing rapidly. Combined heat and power (CHP) plants and wind turbines are most often installed. Integration of these DG units into the distribution grid leads to planning as well as operational challenges. Based on the experience of a Dutch distribution system operators (DSO), this paper addresses several possibilities to handle grid planning issues. Effects on voltage control, grid protection, and fault levels are investigated and described. These aspects are illustrated with the aid of simulations on an existing distribution grid. It is demonstrated that in compact distribution grids voltage control problems and blinding of protection are not likely to occur and that false tripping and fault level have to be considered carefully.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enslin, J. H. R., & Heskes, P. J. M. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.836615 · Cited by 824
Brahma, S. M., & Girgis, A. A. (2004) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2003.820204 · Cited by 679
Voltage rise: the big issue when connecting embedded generation to long 11 kV overhead lines
Masters, C. L. (2002) · Power Engineering Journal · doi:10.1049/pe:20020101 · Cited by 648
Jenkins, N. (2000) · Institution of Engineering and Technology eBooks · doi:10.1049/pbpo031e · Cited by 556
Planning for Distributed Generation
Dugan, R. C., McDermott, T. E., & Ball, G. J. (2001) · IEEE Industry Applications Magazine · doi:10.1109/2943.911193 · Cited by 230
Wind Power Integration: Connection and system operational aspects
Fox, B., Flynn, D., Bryans, L., Jenkins, N., Milborrow, D., O'Malley, M., Watson, R., & Anaya-Lara, O. (2007) · Institution of Engineering and Technology eBooks · doi:10.1049/pbpo050e · Cited by 199
Analysis of the impact of distributed generation on automatic reclosing
Kumpulainen, L., & Kauhaniemi, K. (2005) · IEEE PES Power Systems Conference and Exposition · doi:10.1109/psce.2004.1397623 · Cited by 134
Harmonic interaction between large numbers of photovoltaic inverters and the distribution network
Enslin, J. H. R., Hulshorst, W. T. J., Atmadji, A. M. S., Heskes, P. J. M., Kotsopoulos, A., Cobben, J. F. G., & der Sluijs, P. V. (2004) · doi:10.1109/ptc.2003.1304365 · Cited by 80
Voltage control problems on modern distribution systems
O'Gorman, R., & Redfern, M. A. (2004) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2004.1372894 · Cited by 37
Cited by
Redox flow batteries for the storage of renewable energy: A review
Alotto, P., Guarnieri, M., & Moro, F. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.08.001 · Cited by 1,168
The Smart Transformer: Impact on the Electric Grid and Technology Challenges
Liserre, M., Buticchi, G., Andresen, M., De Carne, G., Costa, L. F., & Zou, Z.-X. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2551418 · Cited by 445
A Survey on Energy Internet: Architecture, Approach, and Emerging Technologies
Wang, K., Yu, J., Yu, Y., Qian, Y., Zeng, D., Guo, S., Xiang, Y., & Wu, J. (2018) · IEEE Systems Journal · doi:10.1109/jsyst.2016.2639820 · Cited by 374
Low-Voltage Ride-Through of Single-Phase Transformerless Photovoltaic Inverters
Yang, Y., Blaabjerg, F., & Wang, H. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2282966 · Cited by 358
Ustun, T. S., Ozansoy, C., & Zayegh, A. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2185072 · Cited by 335
Metadata
- Authors
- Coster, E. J., Myrzik, J. M. A., Kruimer, B., & Kling, W. L.
- Venue
- Proceedings of the IEEE
- Published
- 2011-01
- Volume
- 99
- Issue
- 1
- Pages
- 28-39
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W2032750621
- Cited by
- 422
- References
- 9
- FWCI
- 16.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.