Signal Processing Approaches to Minimize or Suppress Calibration Time in Oscillatory Activity-Based Brain–Computer Interfaces
Open accessThe DOI matches its Crossref record; 86 of the 88 references it cites were found in a registry or an index.
Abstract
One of the major limitations of brain-computer interfaces (BCI) is their long calibration time, which limits their use in practice, both by patients and healthy users alike. Such long calibration times are due to the large between-user variability and thus to the need to collect numerous training electroencephalography (EEG) trials for the machine learning algorithms used in BCI design. In this paper, we first survey existing approaches to reduce or suppress calibration time, these approaches being notably based on regularization, user-to-user transfer, semi-supervised learning and a priori physiological information. We then propose new tools to reduce BCI calibration time. In particular, we propose to generate artificial EEG trials from the few EEG trials initially available, in order to augment the training set size. These artificial EEG trials are obtained by relevant combinations and distortions of the original trials available. We propose three different methods to do so. We also propose a new, fast and simple approach to perform user-to-user transfer for BCI. Finally, we study and compare offline different approaches, both old and new ones, on the data of 50 users from three different BCI data sets. This enables us to identify guidelines about how to reduce or suppress calibration time for BCI.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition, the BCI system requires a long calibration phase before each time it is used because, to achieve a good performance, every subject’s BCI system needs to be trained by their own EEG signals and cannot use other’s EEG signals [11].”
From Transfer Learning Algorithm of P300-EEG Signal Based on XDAWN Spatial Filter and Riemannian Geometry Classifier (2020) · cites this paper as [11]
In the citing paper
“In addition, the BCI system requires a long calibration phase before each time it is used because, to achieve a good performance, every subject’s BCI system needs to be trained by their own EEG signals and cannot use other’s EEG signals [11].”
From Transfer Learning Algorithm of P300-EEG Signal Based on XDAWN Spatial Filter and Riemannian Geometry Classifier (2020) · cites this paper as [11]
In the citing paper
“Classification must generalize across subjects, since per-subject calibration delays setup and limits scalability [4]”
From ERP-XTTN: interpretable prototype-guided cross-attention for cross-subject ERP classification (2026) · cites this paper as [4]
Citations
Cites
Caruana, R. (1997) · Machine Learning · doi:10.1023/a:1007379606734 · Cited by 6,636 · cited 1×
“…guide the optimization algorithms towards good solutions, similar to that of the other users, thus enabling a better learning from little data. b) Multi-task learning: Multi-task learning consists of learning simultaneously multiple tasks that share some constraints or prior information [37].”
BackgroundSemi-Supervised Learning Literature Survey
Zhu, X. (2005) · Minds at UW (University of Wisconsin) · Cited by 4,505
A well-conditioned estimator for large-dimensional covariance matrices
Ledoit, O., & Wolf, M. (2004) · Journal of Multivariate Analysis · doi:10.1016/s0047-259x(03)00096-4 · Cited by 3,046 · cited 3×
“More precisely, it is known that when covariance matrices are estimated from too little training data, their largest and smallest eigen values will be, respectively, over and under estimated [32].”
BackgroundMethodInfluentialA review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665 · cited 2×
“The LDA classifier uses a linear hyperplane to separate feature vectors from two classes [10].”
MethodSelf-citationOptimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 3×
“Since the variance of a band-pass filtered signal corresponds to the band-power of the signal in that band, CSP optimizes spatial filters that lead to optimally discriminant band-power features [29].”
BackgroundMethodInfluentialMotor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990 · cited 1×
“As an example, during left hand motor imagery (i.e., the imagination of a left hand movement), the EEG band power in the (cid:2) (8–12 Hz) and (16–24 Hz) frequency bands will decrease in the right sensorimotor cortex [30].”
BackgroundA tutorial on Principal Components Analysis
Smith, L. I. (2002) · Otago University Research Archive (University of Otago) · Cited by 1,636
Filter Bank Common Spatial Pattern Algorithm on BCI Competition IV Datasets 2a and 2b
Ang, K. K., Chin, Z. Y., Wang, C., Guan, C., & Zhang, H. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00039 · Cited by 1,264 · cited 1×
“…and classifier optimization from limited training data), several algorithms being available to optimize such bands with CSP and LDA; see, e.g., [75]–[81]; 2) outlier/ artifact removal in small sample size settings, as when little data is available, a single outlier (artefacts being…”
MethodSingle-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138 · cited 1×
“Since this is a simple, computationally efficient and parameter free method, we advocate that it should become a standard tool for BCI design, including for oscillatory activity-based BCI (it is already becoming a rather standard tool for ERP classification [74]).”
MethodAn EEG-based brain-computer interface for cursor control
Wolpaw, J. R., McFarland, D. J., Neat, G. W., & Forneris, C. A. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90040-b · Cited by 1,114 · cited 2×
“, [2] and [3].”
Research works printed but not linked: 3
- tu, 0, Dynamical ensemble learning with model-friendly classifiers for domain adaptation, Proc IEEE ICPR, 1181
- lu, 0, Boosting-based subject-independent brain computer interface, Proc ICPR
- meng, 2014, Improved semi-supervised adaptation for small training data set in brain-computer interface, IEEE J Biomed Health Inform, 18
Cited by
Items 301–328 of 328
Data Augmentation for Neuroaesthetics Analysis
Palmieri, M., Avvenuti, M., Marcelloni, F., & Vecchio, A. (2026) · Communications in computer and information science · doi:10.1007/978-3-032-15638-9_45
MAGCANet: A multiscale adaptive graph-convolutional attention network for MI-EEG decoding
Zhu, X., Yin, G., Shi, D., Wang, L., Yan, J., Feng, D., Wei, Z., Wang, Y., Wang, B., Tan, S., et al. (2026) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ae4c94
Source Data Selection for Brain–Computer Interfaces Based on Simple Features
Heskebeck, F., Bergeling, C., & Bernhardsson, B. (2026) · IEEE Access · doi:10.1109/access.2026.3670905 · Cited by 1
“This calibration requirement is one of the main obstacles for everyday ready-to-use BCIs [1].”
黄楚彬, Li, G., Zhong, S.-H., Lu, R., & Gao, T. (2026) · Journal of Visual Communication and Image Representation · doi:10.1016/j.jvcir.2026.104758
Spectral-Temporal Convolutional Transformer for EEG Decoding
Peng, R., Zhang, P., Liao, J., Zuo, X., & Jiang, Z. (2025) · International Conference on Virtual Reality and Visualization · doi:10.1109/icvrv67992.2025.00060
“Finally, these N segments are concatenated in their original order to form a new, enhanced sample with the same dimensionality as the original sample [17].”
Scale as Condition: A Conditional Transformer for Motor Imagery Decoding
Ma, X., Han, T.-S., Kim, H., Kim, H., & Kim, D.-H. (2026) · International Winter Conference on Brain-Computer Interface (BCI) · doi:10.1109/bci69045.2026.11435099
“Given the limited per-subject sample size inherent to EEG acquisition, we also employ segmentation-and-reconstruction (S&R) [28] as a data augmentation strategy for all evaluated baselines to mitigate overfitting.”
Verdière, K. J. (2019) · theses.fr (ABES) · doi:10.70675/50277d0dz64c3z45d2z9f9dzf5f377a679d6 · Cited by 1
“…classifier lies in its simplicity (i.e. it is linear) and its ability to provide good results with a small sample training [Lotte and Guan, 2009, Lotte, 2015]. sLDA has been successfully applied to single trial ERP classification [Blankertz et al., 5.4 classification : labeling mental states…”
InfluentialUser Adapted Brain-Computer Interface
Turi, F. (2020) · theses.fr (ABES) · doi:10.70675/1cc7d8e9z0922z4628za8c6zd476ec105ae4
Rimbert, S. (2020) · theses.fr (ABES) · doi:10.70675/f150ac36z890fz4d60z83ddz912e4bc36c96 · Cited by 1
Avilov, O. (2021) · theses.fr (ABES) · doi:10.70675/e88205f1zf2bfz4c21z999dza3a216d76cdc · Cited by 1
Benaroch, C. (2021) · theses.fr (ABES) · doi:10.70675/c2704384z058az4affza403z92acc3ec08f8 · Cited by 2
Torre, J. J. (2024) · theses.fr (ABES) · doi:10.70675/e4e78df0za2b0z4162z8104z7ae752d81a23 · Cited by 1
Attention-Based Explicit Reconstruction Fusion Network for Motor Imagery Decoding
Hu, Y., Wu, M., Long, B., Chen, T., & Qiu, L. (2026) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp55912.2026.11462558
Papon, J. P., & Ahmad, M. F. H. (2025) · International Conference on Computer and Information Technology (ICCIT) · doi:10.1109/iccit68739.2025.11490504
“In our study, due to the scarcity of MI-EEG data, we adopted the segmentation and recombination (S&R) DA technique [10] to produce synthetic trials.”
ST-Mamba: Dual-Branch State-Space Modeling for EEG Motor Imagery Decoding
Deng, J., Gong, P., Zhu, Q., Shao, Y., Cao, X., Wang, K., Zhang, L., & Zhang, D. (2026) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi61048.2026.11515321
“Data augmentation employs a segmentation–reconstruction [12] scheme, which partitions each trial into overlapping segments and re-assembles them into new samples, improving model generalization under limited data conditions.”
Calero, J. J. R., Villegas, G. M. R., Díaz, J., & Bustamante-Mora, A. (2026) · Applied Sciences · doi:10.3390/app16115423
HMT-Net: A Hybrid Mamba–Transformer Network for Motor Imagery EEG Decoding
Zhang, T., Liao, H., Mu, Y., Junfeng, H., Li, N., Hu, G., & Kong, X. (2026) · Mathematics · doi:10.3390/math14122149
Patchava, V. L., Shaik, H. N. S., Bitra, V. B., Dhulipalla, B. P., Chedella, V. G., & VazramBolla, J. (2026) · AIP conference proceedings · doi:10.1063/5.0342479
Yahya, S. A., Amin, O. A., & Badawy, W. (2026) · International Conference on Machine Intelligence and Smart Innovation (ICMISI) · doi:10.1109/icmisi69868.2026.11584234
“For each EEG channel x ( t ) , the first-order discrete derivative was computed as This strategy has been shown to improve RNN-based classification by highlighting rapid changes in neural oscillations associated with MI [16].”
Zhu, L., Yue, Q., Huang, A., Zhang, J., & Yuan, P. (2026) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2026.2714841
Motor Imagery Classification on the WBCIC-MI Dataset: A Comparative Study
Raisa, N. S., & Habib, M. A. (2026) · International Conference on Power, Electronics, Communications, Computing, and Intelligent Infrastructure (PECCII) · doi:10.1109/peccii70991.2026.11661892
A confidence-gated source selection strategy for cross-session transfer in brain–computer interfaces
Shen, Y., & Degras, D. (2026) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2026.1895016
“Other studies address non-stationarity through stationary spatial filtering, covariate-shift correction, or advanced signal processing techniques designed to minimize recalibration requirements (Samek et al., 2012; Raza et al., 2018; Lotte, 2015).”
STDR-Net: A Spatio-Temporal Dependency Refinement Network for Motor Imagery EEG Decoding
Zhao, W., Dai, J., Pan, Y., Xiao, S., Xie, T., Li, Y., & Yu, Y. (2026) · Brain Sciences · doi:10.3390/brainsci16101051
Sun, W., Fu, S., Zhang, J., Zhu, A., Wang, J., Yin, S., & Liu, G. (2026) · Neural Networks · doi:10.1016/j.neunet.2026.109755
AwareNet: A Topography-Informed Spatio-Temporal Network for Motor Imagery EEG Classification
Gao, M., & Yao, Z. (2026) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn69854.2026.11728437
Contrastive attention network for motor imagery classification using variable length of datasets
Ullah, N., Im, S. J., Kim, T. H., & Park, K. R. (2026) · Applied Soft Computing · doi:10.1016/j.asoc.2026.116730
Zhu, Y., Shi, Y., Wu, J., & Wei, Q. (2026) · PLoS ONE · doi:10.1371/journal.pone.0361026
“Considering the relatively small size of these datasets, the training sets were augmented using the approach segmentation and reconstruction (SR) [43].”
Bharath, M. V., B, T. K., Shalini, K., V, Amardeep, R., Mala, B. A., & R, L. Y. T. (2026) · doi:10.1109/incect72370.2026.11742937
Metadata
- Authors
- Lotte, F.
- Affiliations
- Centre Inria de l'université de Bordeaux (FR)
- Corresponding author
- Lotte, Fabien
- ORCID
- Lotte, Fabien
- Venue
- Proceedings of the IEEE
- Published
- 2015-06
- Volume
- 103
- Issue
- 6
- Pages
- 871-890
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W1610928686
- Cited by
- 327
- References
- 88
- Citations by year
- 2026: 29 · 2025: 45 · 2024: 36 · 2023: 28 · 2022: 38 · 2021: 30 · 2020: 36 · 2019: 29 · 2018: 25 · 2017: 12 · 2016: 16 · 2015: 3
- FWCI
- 11.10
- Type
- journal article
- Language
- en
- Open access
- green
- inria.hal.science
- Locations
- Proceedings of the IEEE (publishedVersion)
- HAL (submittedVersion, other-oa)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
- Keywords
- brain-computer interface, calibration time reduction, EEG, neural oscillations, semi-supervised learning, regularization, data augmentation, training data size
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.