CoChat

Metrology State-of-the-Art and Challenges in Broadband Phase-Sensitive Terahertz Measurements

The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.

Abstract

The two main modalities for making broadband phase-sensitive measurements at terahertz (THz) frequencies are vector network analyzers (VNA) and time-domain spectrometers (TDS). These measuring instruments have separate and fundamentally different operating principles and methodologies, and they serve very different application spaces. The different architectures give rise to different measurement challenges and metrological solutions. This article reviews these two measurement techniques and discusses the different issues involved in making measurements using these systems. Calibration, verification, and measurement traceability issues are reviewed, along with other major challenges facing these instrument architectures in the years to come. The differences in, and similarities between, the two measurement methods are discussed and analyzed. Finally, the operating principles of electro-optic sampling (EOS) are briefly discussed. This technique has some similarities to TDS and shares application space with the VNA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jproc.2016.2644108

Cites

78 of 78 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 78 references

Research works printed but not linked: 5

  1. hale, 2012, Traceability of high-speed electrical waveforms atNIST, NPL, and PTB, Proc Conf Prec Electromagn Meas, 522
  2. 2008, Evaluation of Measurement Data—Guide to the Expression of the Uncertainty in Measurement (GUM 1995) JCGM 100 2008
  3. 2004, Frequency extension source modules to extend signal capability from 50 to 325 GHz, Microw J, 47, 124
  4. 2002, Waveguides Rigid Rectangular (Millimetre Wavelength)
  5. naftaly, 2015, Terahertz Metrology

Cited by

Metadata

Authors
Naftaly, M., Clarke, R. G., Humphreys, D. A., & Ridler, N. M.
Affiliations
  • National Physical Laboratory (GB)
  • University of Leeds (GB)
Venue
Proceedings of the IEEE
Published
2017-06
Volume
105
Issue
6
Pages
1151-1165
ISSN
  • 0018-9219 (ISSN-L)
  • 1558-2256
OpenAlex
W2581727296
Cited by
49
References
78
Citations by year
2026: 6 · 2025: 10 · 2024: 4 · 2023: 6 · 2022: 4 · 2021: 5 · 2020: 1 · 2019: 4 · 2018: 4 · 2017: 5
FWCI
1.59
Type
journal article
Language
en
Open access
closed
Locations
  • Proceedings of the IEEE (publishedVersion)
  • White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
Keywords
terahertz metrology, vector network analyzer, electro-optic sampling, measurement traceability, calibration, verification, measurement uncertainty

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.