Metrology State-of-the-Art and Challenges in Broadband Phase-Sensitive Terahertz Measurements
The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.
Abstract
The two main modalities for making broadband phase-sensitive measurements at terahertz (THz) frequencies are vector network analyzers (VNA) and time-domain spectrometers (TDS). These measuring instruments have separate and fundamentally different operating principles and methodologies, and they serve very different application spaces. The different architectures give rise to different measurement challenges and metrological solutions. This article reviews these two measurement techniques and discusses the different issues involved in making measurements using these systems. Calibration, verification, and measurement traceability issues are reviewed, along with other major challenges facing these instrument architectures in the years to come. The differences in, and similarities between, the two measurement methods are discussed and analyzed. Finally, the operating principles of electro-optic sampling (EOS) are briefly discussed. This technique has some similarities to TDS and shares application space with the VNA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The Fourier transform scrambles the THz-TDS measurement noise, which is more naturally represented in the time domain”
From Maximum-likelihood parameter estimation in terahertz time-domain spectroscopy (2021) · cites this paper as [7]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“produces artifacts that can degrade the overall measurement quality and yield misleading results [4-13].”
From Maximum-likelihood parameter estimation in terahertz time-domain spectroscopy (2021) · cites this paper as [7]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foundations for Microwave Engineering
Clarricoats, P. J. B. (1967) · Electronics and Power · doi:10.1049/ep.1967.0023 · Cited by 2,686
Far-infrared time-domain spectroscopy with terahertz beams of dielectrics and semiconductors
Grischkowsky, D., Keiding, S., van Exter, M., & Fattinger, C. (1990) · Journal of the Optical Society of America B · doi:10.1364/josab.7.002006 · Cited by 2,239
Engen, G. F., & Hoer, C. A. (1979) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.1979.1129778 · Cited by 1,595
A multiline method of network analyzer calibration
Marks, R. B. (1991) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.85388 · Cited by 1,285
A reliable method for extraction of material parameters in terahertz time-domain spectroscopy
Duvillaret, L., Garet, F., & Coutaz, J.-L. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.571775 · Cited by 994
Material parameter estimation with terahertz time-domain spectroscopy
Dorney, T. D., Baraniuk, R. G., & Mittleman, D. M. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001562 · Cited by 807
The Six-Port Reflectometer: An Alternative Network Analyzer
Engen, G. F. (1977) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.1977.1129277 · Cited by 630
Duvillaret, L., Garet, F., & Coutaz, J.-L. (1999) · Applied Optics · doi:10.1364/ao.38.000409 · Cited by 505
A general waveguide circuit theory
Marks, R. B., & Williams, D. F. (1992) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.097.024 · Cited by 418
Dynamic range in terahertz time-domain transmission and reflection spectroscopy
Jepsen, P. U., & Fischer, B. M. (2005) · Optics Letters · doi:10.1364/ol.30.000029 · Cited by 382 · cited 4×
“[45] P. U. Jepsen and B. M. Fischer, Dynamic range in terahertz time domain transmission and reflection spectroscopy, Opt.”
BackgroundInfluential
Research works printed but not linked: 5
- hale, 2012, Traceability of high-speed electrical waveforms atNIST, NPL, and PTB, Proc Conf Prec Electromagn Meas, 522
- 2008, Evaluation of Measurement Data—Guide to the Expression of the Uncertainty in Measurement (GUM 1995) JCGM 100 2008
- 2004, Frequency extension source modules to extend signal capability from 50 to 325 GHz, Microw J, 47, 124
- 2002, Waveguides Rigid Rectangular (Millimetre Wavelength)
- naftaly, 2015, Terahertz Metrology
Cited by
Terahertz Communications and Sensing for 6G and Beyond: A Comprehensive Review
Jiang, W., Zhou, Q., He, J., Habibi, M. A., Melnyk, S., El-Absi, M., Han, B., Renzo, M. D., Schotten, H. D., Luo, F.-L., et al. (2024) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2024.3385908 · Cited by 552
Terahertz time-domain spectroscopy
Koch, M., Mittleman, D. M., Ornik, J., & Castro-Camus, E. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00232-z · Cited by 410
The Road to 6G: Ten Physical Layer Challenges for Communications Engineers
Matthaiou, M., Yurduseven, O., Ngo, H. Q., Morales-Jimenez, D., Cotton, S. L., & Fusco, V. F. (2021) · IEEE Communications Magazine · doi:10.1109/mcom.001.2000208 · Cited by 370
Terahertz Wireless Channels: A Holistic Survey on Measurement, Modeling, and Analysis
Han, C., Wang, Y., Li, Y., Chen, Y., Abbasi, N. A., Kurner, T., & F. Molisch, A. (2022) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2022.3182539 · Cited by 352
A Review of Integrated Systems and Components for 6G Wireless Communication in the D-Band
Maiwald, T., Li, T., Hotopan, G. R., Kolb, K., Disch, K., Potschka, J., Haag, A., Dietz, M., Debaillie, B., Zwick, T., et al. (2023) · Proceedings of the IEEE · doi:10.1109/jproc.2023.3240127 · Cited by 189
“From a mathematical point of view, all known calibration and deembedding theories also apply for D-band frequencies, but creating accurate broadband termination impedances (such as open, short, and load) is quite challenging, which is why transmission line-based calibration and deembedding methods are favorable at the…”
Background
Metadata
- Authors
- Naftaly, M., Clarke, R. G., Humphreys, D. A., & Ridler, N. M.
- Affiliations
- National Physical Laboratory (GB)
- University of Leeds (GB)
- Venue
- Proceedings of the IEEE
- Published
- 2017-06
- Volume
- 105
- Issue
- 6
- Pages
- 1151-1165
- ISSN
- 0018-9219 (ISSN-L)
- 1558-2256
- OpenAlex
- W2581727296
- Semantic Scholar
- 3c63f85b0c99016cbb2d38a52cc26ac790c064a7
- Cited by
- 49
- References
- 78
- Citations by year
- 2026: 6 · 2025: 10 · 2024: 4 · 2023: 6 · 2022: 4 · 2021: 5 · 2020: 1 · 2019: 4 · 2018: 4 · 2017: 5
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Proceedings of the IEEE (publishedVersion)
- White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
- Keywords
- terahertz metrology, vector network analyzer, electro-optic sampling, measurement traceability, calibration, verification, measurement uncertainty
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.