Subpicosecond electrical sampling
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
We report on the recent advances of an electrooptic sampling technique for the characterization of electrical transients that has now achieved an unprecedented temporal resolution of less than 1 ps. Voltage sensitivity is on the order of 50 μV. A lithium tantalate traveling wave Pockels cell is employed in conjunction with a high repetition rate subpicosecond laser system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generation of optical pulses shorter than 0.1 psec by colliding pulse mode locking
Fork, R. L., Greene, B. I., & Shank, C. V. (1981) · Applied Physics Letters · doi:10.1063/1.92500 · Cited by 886
Picosecond optoelectronic switching and gating in silicon
Auston, D. H. (1975) · Applied Physics Letters · doi:10.1063/1.88079 · Cited by 768
Picosecond electro-optic sampling system
Valdmanis, J. A., Mourou, G., & Gabel, C. W. (1982) · Applied Physics Letters · doi:10.1063/1.93485 · Cited by 359
Self-citationAuston, D. H., Johnson, A. M., Smith, P. R., & Bean, J. C. (1980) · Applied Physics Letters · doi:10.1063/1.91947 · Cited by 230
Picosecond photoconductivity in radiation-damaged silicon-on-sapphire films
Smith, P. R., Auston, D. H., Johnson, A. M., & Augustyniak, W. M. (1981) · Applied Physics Letters · doi:10.1063/1.92128 · Cited by 164
An amorphous silicon photodetector for picosecond pulses
Auston, D. H., Lavallard, P., Sol, N., & Kaplan, D. (1980) · Applied Physics Letters · doi:10.1063/1.91276 · Cited by 142
Picosecond photoconductivity in germanium films
DeFonzo, A. P. (1981) · Applied Physics Letters · doi:10.1063/1.92766 · Cited by 28
Cited by
Materials for terahertz science and technology
Ferguson, B., & Zhang, X.-C. (2002) · Nature Materials · doi:10.1038/nmat708 · Cited by 3,284
Picosecond photoconducting Hertzian dipoles
Auston, D. H., Cheung, K. P., & Smith, P. R. (1984) · Applied Physics Letters · doi:10.1063/1.95174 · Cited by 1,037
Cherenkov Radiation from Femtosecond Optical Pulses in Electro-Optic Media
Auston, D. H., Cheung, K. P., Valdmanis, J. A., & Kleinman, D. A. (1984) · Physical Review Letters · doi:10.1103/physrevlett.53.1555 · Cited by 648
Self-citationElectrooptical generation and detection of femtosecond electrical transients
Auston, D. H., & Nuss, M. C. (1988) · IEEE Journal of Quantum Electronics · doi:10.1109/3.114 · Cited by 347
Double modulated differential THz-TDS for thin film dielectric characterization
Mickan, S. P., Lee, K.-S., Lu, T.-M., Munch, J., Abbott, D., & Zhang, X.-C. (2002) · Microelectronics Journal · doi:10.1016/s0026-2692(02)00108-8 · Cited by 54
Heuristic approach to take up the challenge of terahertz time-domain spectroscopy for biology
Lavancier, M. (2026) · doi:10.70675/ae6227b6zb5e7z43aczb2dcza96e56b2799e · Cited by 3
Metadata
- Authors
- Valdmanis, J., Mourou, G., & Gabel, C.
- Venue
- IEEE Journal of Quantum Electronics
- Published
- 1983-04
- Volume
- 19
- Issue
- 4
- Pages
- 664-667
- ISSN
- 0018-9197 (ISSN-L)
- OpenAlex
- W2081623882
- Cited by
- 195
- References
- 7
- FWCI
- 14.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.