Flexible Optical Fiber Bending Transducer for Application in Glove-Based Sensors
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The development of a low-cost and flexible optical fiber transducer for measurement of angular displacements is reported. The light intensity attenuation due to fiber microbending losses is correlated to the variations in flexing angle, yielding to a sensitivity of 1.80°. The device was also mounted in a fabric glove to the monitoring of flexion and abduction movements of index and thumb fingers. Once calibrated by a simple procedure, the glove-based system was capable to measure the angular positions with average errors <;5° and 7° for interphalangeal and metacarpophalangeal joints, respectively. Additionally, the repeatability analysis resulted in average range and standard deviations of 8.06° and 3.45°, respectively. The optical fiber sensor provides a low-cost alternative to the real-time monitoring of hand posture, and can be suitable for applications in human-robot and human-computer interactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A stretchable carbon nanotube strain sensor for human-motion detection
Yamada, T., Hayamizu, Y., Yamamoto, Y., Yomogida, Y., Izadi-Najafabadi, A., Futaba, D. N., & Hata, K. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.36 · Cited by 3,247
Human motion tracking for rehabilitation-A survey
Zhou, H., & Hu, H. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.001 · Cited by 813
Cited by
Zhu, M., Sun, Z., Zhang, Z., Shi, Q., He, T., Liu, H., Chen, T., & Lee, C. (2020) · Science Advances · doi:10.1126/sciadv.aaz8693 · Cited by 784
“Recently, attempts to use optical sensing have also been reported ( 9 ).”
Triboelectric nanogenerator sensors for soft robotics aiming at digital twin applications
Jin, T., Sun, Z., Li, L., Zhang, Q., Zhu, M., Zhang, Z., Yuan, G., Chen, T., Tian, Y., Hou, X., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19059-3 · Cited by 695
Hand Gesture Recognition Based on Computer Vision: A Review of Techniques
Oudah, M., Al-Naji, A., & Chahl, J. (2020) · Journal of Imaging · doi:10.3390/jimaging6080073 · Cited by 635
Ultrasensitive skin-like wearable optical sensors based on glass micro/nanofibers
Zhang, L., Pan, J., Zhang, Z., Wu, H., Yao, N., Cai, D., Xu, Y., Zhang, J., Sun, G., Wang, L., et al. (2020) · Opto-Electronic Advances · doi:10.29026/oea.2020.190022 · Cited by 186
American sign language recognition and training method with recurrent neural network
Lee, C. K. M., Ng, K. K. H., Chen, C.-H., Lau, H. C. W., Chung, S. Y., & Tsoi, T. (2021) · Expert Systems with Applications · doi:10.1016/j.eswa.2020.114403 · Cited by 178
A multifunctional skin-like wearable optical sensor based on an optical micro-/nanofibre
Pan, J., Zhang, Z., Jiang, C., Zhang, L., & Tong, L. (2020) · Nanoscale · doi:10.1039/d0nr03446k · Cited by 130
Metadata
- Authors
- Fujiwara, E., Ferreira Marques Dos Santos, M., & Suzuki, C. K.
- Venue
- IEEE Sensors Journal
- Published
- 2014-10
- Volume
- 14
- Issue
- 10
- Pages
- 3631-3636
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- OpenAlex
- W2328600319
- Cited by
- 71
- References
- 2
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.