Cited by 66Non-Invasive Vital Sign MonitoringECG Monitoring and AnalysisWireless Body Area Networks

Wireless Capacitive-Based ECG Sensing for Feature Extraction and Mobile Health Monitoring

Wannenburg, Johan, Malekian, Reza, Hancke, Gerhard P.·2018·IEEE Sensors Journal

Abstract

In this paper, the concept of a wireless wearable device capable of measuring electrocardiogram (ECG) and respiration rate (RR) through the use of non-contact capacitive-based electrodes was designed and implemented. Both ECG and RR were measured using only the active electrodes and an analog conditioning circuit. The device utilizes Bluetooth low energy for low-power wireless communication to the remote server. The measured data is used to calculate heart rate variability, RR, and extract ECG related features. It was found that the use of non-contact active chest electrodes is a viable approach for measurement. The system focuses on user comfort and the minimization of the ratio of the number of wearable sensors to sensed physiological parameters.

Integrity signals

Registry

Crossref · 10.1109/jsen.2018.2844122

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wannenburg, J., Malekian, R., & Hancke, G. P.
Affiliations
University of Pretoria (ZA)
Venue
IEEE Sensors Journal
Published
2018-07-15
Volume
18
Issue
14
Pages
6023-6032
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W2806290004
Cited by
66
References
26
Citations by year
2026: 2 · 2025: 5 · 2024: 8 · 2023: 8 · 2022: 8 · 2021: 8 · 2020: 14 · 2019: 11 · 2018: 2
FWCI
3.50
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Sensors Journal (publishedVersion)
  • UpSpace Institutional Repository (University of Pretoria) (submittedVersion)
Funders
National Research Foundation of South Africa (IFR160118156967, RDYR160404161474)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
capacitive electrodes, wearable sensors, respiration rate monitoring, heart rate variability, ECG feature extraction, Bluetooth Low Energy, mobile health monitoring, low-power wireless communication

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review