The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems
Open accessAbstract
There is a growing demand for low-power, small-size and ambulatory biopotential acquisition systems. A crucial and important block of this acquisition system is the analog readout front-end. We have implemented a low-power and low-noise readout front-end with configurable characteristics for Electroencephalogram (EEG), Electrocardiogram (ECG), and Electromyogram (EMG) signals. Key to its performance is the new AC-coupled chopped instrumentation amplifier (ACCIA), which uses a low power current feedback instrumentation amplifier (IA). Thus, while chopping filters the 1/f noise of CMOS transistors and increases the CMRR, AC coupling is capable of rejecting differential electrode offset (DEO) up to${\pm}$50 mV from conventional Ag/AgCl electrodes. The ACCIA achieves 120 dB CMRR and 57 nV/$\surd$Hz input-referred voltage noise density, while consuming 11.1$\mu$A from a 3 V supply. The chopping spike filter (CSF) stage filters the chopping spikes generated by the input chopper of ACCIA and the digitally controllable variable gain stage is used to set the gain and the bandwidth of the front-end. The front-end is implemented in a 0.5$\mu$m CMOS process. Total current consumption is 20$\mu$A from 3V.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design of Analog CMOS Integrated Circuits
Razavi, B. (1999) · Cited by 6,609
Enz, C. C., & Temes, G. C. (1996) · Proceedings of the IEEE · doi:10.1109/5.542410 · Cited by 1,877
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
Enhancing the quality of life through wearable technology
Park, S., & Jayaraman, S. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213625 · Cited by 614
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
A high-swing, high-impedance MOS cascode circuit
Sackinger, E., & Guggenbuhl, W. (1990) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.50316 · Cited by 514
Metting van Rijn, A. C., Peper, A., & Grimbergen, C. A. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441666 · Cited by 450
High-quality recording of bioelectric events: Part 1 Interference reduction, theory and practice
Metting van Rijn, A. C., Peper, A., & Grimbergen, C. A. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441961 · Cited by 427
A CMOS analog front-end IC for portable EEG/ECG monitoring applications
Ng, K. A., & Chan, P. K. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.854141 · Cited by 229
A Multiparameter Wearable Physiologic Monitoring System for Space and Terrestrial Applications
Mundt, C. W., Montgomery, K. N., Udoh, U. E., Barker, V. N., Thonier, G. C., Tellier, A. M., Ricks, R. D., Darling, R. B., Cagle, Y. D., Cabrol, N. A., et al. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854509 · Cited by 226
A CMOS nested-chopper instrumentation amplifier with 100-nV offset
Bakker, A., Thiele, K., & Huijsing, J. H. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.890300 · Cited by 225
A micropower dry-electrode ECG preamplifier
Burke, M. J., & Gleeson, D. T. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.821734 · Cited by 164
Noise sources and calculation techniques for switched capacitor filters
Fischer, J. H. (1982) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1982.1051806 · Cited by 157
A CMOS IC for portable EEG acquisition systems
Martins, R. E., Selberherr, S., & Vaz, F. (1998) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.746581 · Cited by 138
New horizons in ambulatory electroencephalography
Waterhouse, E. J. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213629 · Cited by 129
A Micropower CMOS-Instrumentation Amplifier
Degrauwe, M. G. R., Vittoz, E. A., & Verbauwhede, I. M. R. (1985) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1985.1052386 · Cited by 126
A CMOS IC for portable EEG acquisition systems
Martins, R. E., Selberherr, S., & Vaz, F. (2002) · Conference proceedings - IEEE Instrumentation/Measurement Technology Conference · doi:10.1109/imtc.1998.676985 · Cited by 118
A fully integrated, untrimmed CMOS instrumentation amplifier with submicrovolt offset
Menolfi, C., & Huang, Q. (1999) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.748194 · Cited by 102
Micropower high-performance SC building block for integrated low-level signal processing
Peteghem, P. M. V., Verbauwhede, I. M. R., & Sansen, W. (1985) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1985.1052397 · Cited by 41
Integrated CMOS Amplifier for ENG Signal Recording
Uranga, A., Navarro, X., & Barniol, N. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.834253 · Cited by 33
Cited by
Energy Harvesting for Autonomous Wireless Sensor Networks
Vullers, R., Schaijk, R., Visser, H., Penders, J., & Hoof, C. (2010) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2010.936667 · Cited by 625
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451
A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
Zou, X., Xu, X., Yao, L., & Lian, Y. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014707 · Cited by 414
Implementation of wireless body area networks for healthcare systems
Yuce, M. R. (2010) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2010.06.004 · Cited by 331
A 200 μW Eight-Channel EEG Acquisition ASIC for Ambulatory EEG Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006462 · Cited by 271
Self-citation
Metadata
- Authors
- Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2007-05
- Volume
- 42
- Issue
- 5
- Pages
- 1100-1110
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2147498826
- Cited by
- 382
- References
- 21
- FWCI
- 20.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.