Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 271

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A 200 μW Eight-Channel EEG Acquisition ASIC for Ambulatory EEG Systems

Yazicioglu, Refet Firat, Merken, Patrick, Puers, Robert, Van Hoof, Chris·2008·IEEE Journal of Solid-State Circuits

Abstract

The growing interest toward the improvement of patients' quality of life and the use of medical signals in nonmedical applications such as entertainment, sports, and brain–computerinterfaces, requires the implementation of miniaturized and wireless biopotential acquisition systems with ultralow power dissipation. Therefore, this paper presents the implementation of a complete EEG acquisition ASIC tailored towards the needs of such applications, i.e., high-signal quality, low-power dissipation and ease of use. The presented ASIC includes eight readout front-end channels and an 11-bit analog-to-digital converter (ADC). The key to its high performance and low-power dissipation is the new AC coupled chopper stabilized instrumentation amplifier (ACCIA) implementation that uses a coarse–fine servoloop and reaches more than 120 dB CMRR, consumes only 2.3$\mu{\hbox{A}}$, and achieves a noise–efficiency factor (NEF) of 4.3. Furthermore, the ease of use of the ASIC is realized by incorporating Calibration and Electrode Impedance Measurement Modes to the ASIC. Therefore, the former can be used to check the functionality of the ASIC, as well as, to calibrate the gain matching of the channels, where as the latter can be used to track the quality of the biopotential electrode. The ASIC is implemented in 0.5$\mu{\hbox{m}}$CMOS process and the total current consumption is 66$\mu{\hbox{A}}$from 3 V.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/jssc.2008.2006462

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 271

Metadata

Authors
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C.
Venue
IEEE Journal of Solid-State Circuits
Published
2008-12
Volume
43
Issue
12
Pages
3025-3038
ISSN
  • 0018-9200 (ISSN-L)
  • 1558-173X
OpenAlex
W2122617960
Cited by
271
References
1
FWCI
11.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A 200 μW Eight-Channel EEG Acquisition ASIC for Ambulatory EEG Systems. https://app.cochat.ai/papers/10.1109/jssc.2008.2006462
The paper
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2008). A 200 μW Eight-Channel EEG Acquisition ASIC for Ambulatory EEG Systems. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2008.2006462

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.