The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
A 200 μW Eight-Channel EEG Acquisition ASIC for Ambulatory EEG Systems
Abstract
The growing interest toward the improvement of patients' quality of life and the use of medical signals in nonmedical applications such as entertainment, sports, and brain–computerinterfaces, requires the implementation of miniaturized and wireless biopotential acquisition systems with ultralow power dissipation. Therefore, this paper presents the implementation of a complete EEG acquisition ASIC tailored towards the needs of such applications, i.e., high-signal quality, low-power dissipation and ease of use. The presented ASIC includes eight readout front-end channels and an 11-bit analog-to-digital converter (ADC). The key to its high performance and low-power dissipation is the new AC coupled chopper stabilized instrumentation amplifier (ACCIA) implementation that uses a coarse–fine servoloop and reaches more than 120 dB CMRR, consumes only 2.3$\mu{\hbox{A}}$, and achieves a noise–efficiency factor (NEF) of 4.3. Furthermore, the ease of use of the ASIC is realized by incorporating Calibration and Electrode Impedance Measurement Modes to the ASIC. Therefore, the former can be used to check the functionality of the ASIC, as well as, to calibrate the gain matching of the channels, where as the latter can be used to track the quality of the biopotential electrode. The ASIC is implemented in 0.5$\mu{\hbox{m}}$CMOS process and the total current consumption is 66$\mu{\hbox{A}}$from 3 V.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Klem, G. H., Lüders, H. O., Jasper, H. H., & Elger, C. E. (1999) · PubMed · Cited by 2,361
Enz, C. C., & Temes, G. C. (1996) · Proceedings of the IEEE · doi:10.1109/5.542410 · Cited by 1,877
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A 4-MHz CMOS continuous-time filter with on-chip automatic tuning
Krummenacher, F., & Joehl, N. (1988) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.315 · Cited by 697
IFCN standards for digital recording of clinical EEG
Nuwer, M. R., Comi, G., Emerson, R., Fuglsang-Frederiksen, A., Guérit, J.-M., Hinrichs, H., Ikeda, A., Jose C. Luccas, F., & Rappelsburger, P. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(97)00106-5 · Cited by 671
Enhancing the quality of life through wearable technology
Park, S., & Jayaraman, S. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213625 · Cited by 614
A micropower low-noise monolithic instrumentation amplifier for medical purposes
Steyaert, M. S. J., & Sansen, W. M. C. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052869 · Cited by 577
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451
Metting van Rijn, A. C., Peper, A., & Grimbergen, C. A. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441666 · Cited by 450
High-quality recording of bioelectric events: Part 1 Interference reduction, theory and practice
Metting van Rijn, A. C., Peper, A., & Grimbergen, C. A. (1990) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441961 · Cited by 427
A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.894804 · Cited by 382
Self-citationEnz, C. C., Vittoz, E. A., & Krummenacher, F. (1987) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1987.1052730 · Cited by 241
New horizons in ambulatory electroencephalography
Waterhouse, E. J. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213629 · Cited by 129
A 100-MHz pipelined CMOS comparator
Wu, J.-T., & Wooley, B. A. (1988) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.90034 · Cited by 107
A 200μW Eight-Channel Acquisition ASIC for Ambulatory EEG Systems
Yazıcıoğlu, R. F., Merken, P. J., Puers, R., & Hoof, C. A. V. (2008) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2008.4523108 · Cited by 67
Self-citationA fully-integrated bandpass amplifier for extracellular neural recording
Olsson, R. H., Gulari, A. N., & Wise, K. D. (2003) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2003.1196783 · Cited by 54
Cited by
Wearable Electroencephalography
Casson, A., Yates, D., Smith, S., Duncan, J., & Rodriguez-Villegas, E. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936545 · Cited by 404
A Minimally Invasive 64-Channel Wireless μECoG Implant
Muller, R., Le, H.-P., Li, W., Ledochowitsch, P., Gambini, S., Bjorninen, T., Koralek, A., Carmena, J. M., Maharbiz, M. M., Alon, E., et al. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2364824 · Cited by 372
Wu, R., Makinwa, K. A. A., & Huijsing, J. H. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2032710 · Cited by 288
An Implantable 455-Active-Electrode 52-Channel CMOS Neural Probe
Lopez, C. M., Andrei, A., Mitra, S., Welkenhuysen, M., Eberle, W., Bartic, C., Puers, R., Yazicioglu, R. F., & Gielen, G. G. E. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284347 · Cited by 264
Self-citationThe 128-Channel Fully Differential Digital Integrated Neural Recording and Stimulation Interface
Shahrokhi, F., Abdelhalim, K., Serletis, D., Carlen, P. L., & Genov, R. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2041350 · Cited by 263
Metadata
- Authors
- Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2008-12
- Volume
- 43
- Issue
- 12
- Pages
- 3025-3038
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2122617960
- Cited by
- 271
- References
- 17
- FWCI
- 11.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.