High Dynamic Range CMOS Imager Technologies for Biomedical Applications
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Apart from the ongoing debate about using CMOS active pixel sensors (APS) or CCD imagers for today's consumer and commercial applications the emerging biomedical market presents new opportunities to CMOS APS. Logarithmic response high-dynamic range CMOS (HDRC) cells are the preferred photosensitive circuits for building sensors with contrast and not with illumination dominated outputs. Prominent examples addressing distinct issues in life style and health care are the possibilities to restore vision through a sub-retinal CMOS imager implant and to fabricate a low-cost intracorporeal video probe through a miniature CMOS imager. The sub-retinal imager chip presented here is the first implanted into the eye of a blind human patient with partial restoring of vision.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iddan, G., Meron, G., Glukhovsky, A., & Swain, P. (2000) · Nature · doi:10.1038/35013140 · Cited by 3,066
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478
Rousche, P. J., & Normann, R. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.750552 · Cited by 187
Cited by
Noorsal, E., Sooksood, K., Xu, H., Hornig, R., Becker, J., & Ortmanns, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2164667 · Cited by 212
Wilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155
“and applies a constant-voltage signal at the respective microelectrode.(38,39); and (2) an additional electrode array of 16 hard-wired electrodes for light-independent direct-stimulation experiments (DS array).”
BackgroundA Fully Intraocular High-Density Self-Calibrating Epiretinal Prosthesis
Monge, M., Raj, M., Nazari, M. H., Chang, H.-C., Zhao, Y., Weiland, J. D., Humayun, M. S., Tai, Y.-C., & Emami, A. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2298334 · Cited by 85
Metadata
- Authors
- Graf, H.-G., Harendt, C., Engelhardt, T., Scherjon, C., Warkentin, K., Richter, H., & Burghartz, J. N.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2009-01
- Volume
- 44
- Issue
- 1
- Pages
- 281-289
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W2122463094
- Cited by
- 55
- References
- 3
- FWCI
- 3.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High Dynamic Range CMOS Imager Technologies for Biomedical Applications. https://app.cochat.ai/papers/10.1109/jssc.2008.2007437
- The paper
- Graf, H.-G., Harendt, C., Engelhardt, T., Scherjon, C., Warkentin, K., Richter, H., & Burghartz, J. N. (2009). High Dynamic Range CMOS Imager Technologies for Biomedical Applications. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2008.2007437
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.