Cited by 85Neuroscience and Neural EngineeringAnalog and Mixed-Signal Circuit DesignCCD and CMOS Imaging Sensors

A Fully Intraocular High-Density Self-Calibrating Epiretinal Prosthesis

Monge, Manuel, Raj, Mayank, Nazari, Meisam Honarvar, Han-Chieh Chang, Yu Zhao, Weiland, James D., Humayun, Mark S., Yu-Chong Tai +1 more·2013·IEEE Transactions on Biomedical Circuits and Systems

Abstract

This paper presents a fully intraocular self-calibrating epiretinal prosthesis with 512 independent channels in 65 nm CMOS. A novel digital calibration technique matches the biphasic currents of each channel independently while the calibration circuitry is shared among every 4 channels. Dual-band telemetry for power and data with on-chip rectifier and clock recovery reduces the number of off-chip components. The rectifier utilizes unidirectional switches to prevent reverse conduction loss in the power transistors and achieves an efficiency > 80%. The data telemetry implements a phase-shift keying (PSK) modulation scheme and supports data rates up to 20 Mb/s. The system occupies an area of 4.5 ×3.1 mm². It features a pixel size of 0.0169 mm² and arbitrary waveform generation per channel. In vitro measurements performed on a Pt/Ir concentric bipolar electrode in phosphate buffered saline (PBS) are presented. A statistical measurement over 40 channels from 5 different chips shows a current mismatch with μ = 1.12 μA and σ = 0.53 μA. The chip is integrated with flexible MEMS origami coils and parylene substrate to provide a fully intraocular implant.

Integrity signals

Registry

Crossref · 10.1109/tbcas.2014.2298334

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Active charge balancing can be achieved by continuous adjustment of the source/sink currents with dynamic current copying in push-pull architectures, and by insertion of a short pulse train that instantaneously corrects the residual charge, or via compensation of the excess charge as an offset current.

    “This can be achieved by continuous adjustment of the source/sink currents with dynamic current copying in pushpull architectures, [44], [66], and by insertion of a short pulse train that instantaneously corrects the residual charge, or via compensation of the excess charge as an offset current [135], [144].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Monge, M., Raj, M., Nazari, M. H., Chang, H.-C., Zhao, Y., Weiland, J. D., Humayun, M. S., Tai, Y.-C., & Emami, A.
Affiliations
  • California Institute of Technology (US)
  • University of Southern California (US)
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2013-12
Volume
7
Issue
6
Pages
747-760
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2090583902
Cited by
85
References
44
Citations by year
2026: 2 · 2025: 1 · 2024: 14 · 2023: 6 · 2022: 13 · 2021: 7 · 2020: 2 · 2019: 9 · 2018: 10 · 2017: 7 · 2016: 5 · 2015: 3 · 2014: 6
FWCI
2.28
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
  • PubMed (publishedVersion)
  • CaltechAUTHORS (California Institute of Technology) (submittedVersion)
Funders
NSF Biomimetic MicroElectronic Systems¿Engineering Research Center (BMES-ERC)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › CCD and CMOS Imaging Sensors
Keywords
epiretinal prosthesis, intraocular implants, self-calibration, digital calibration, CMOS integrated circuit, phase-shift keying, bipolar electrodes, current mismatch, parylene substrate, flexible implants, retinal prosthesis
MeSH terms
Calibration, Electronics, Medical, Equipment Design, Humans, Models, Biological, Telemetry, Visual Prosthesis, Neural Prostheses

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review