A Wireless and Batteryless 10-Bit Implantable Blood Pressure Sensing Microsystem With Adaptive RF Powering for Real-Time Laboratory Mice Monitoring
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
An implantable real-time blood pressure monitoring microsystem for laboratory mice has been demonstrated. The system achieves a 10-bit blood pressure sensing resolution and can wirelessly transmit the pressure information to an external unit. The implantable device is operated in a batteryless manner, powered by an external RF power source. The received RF power level can be sensed and wirelessly transmitted along with blood pressure signal for feedback control of the external RF power. The microsystem employs an instrumented silicone cuff, wrapped around a blood vessel with a diameter of approximately 200 ¿m, for blood pressure monitoring. The cuff is filled by low-viscosity silicone oil with an immersed MEMS capacitive pressure sensor and integrated electronic system to detect a down-scaled vessel blood pressure waveform with a scaling factor of approximately 0.1. The integrated electronic system, consisting of a capacitance-to-voltage converter, an 11-bit ADC, an adaptive RF powering system, an oscillator-based 433 MHz FSK transmitter and digital control circuitry, is fabricated in a 1.5 ¿m CMOS process and dissipates a power of 300 ¿W. The packaged microsystem weighs 130 milligram and achieves a capacitive sensing resolution of 75 aF over 1 kHz bandwidth, equivalent to a pressure sensing resolution of 1 mmHg inside an animal vessel, with a dynamic range of 60 dB. Untethered laboratory animalin vivoevaluation demonstrates that the microsystem can capture real-time blood pressure information with a high fidelity under an adaptive RF powering and wireless data telemetry condition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analog Integrated Circuit Design
Carusone, A. C., Johns, D. A., & Martin, K. W. (1996) · Cited by 2,509
Enz, C. C., & Temes, G. C. (1996) · Proceedings of the IEEE · doi:10.1109/5.542410 · Cited by 1,877 · cited 2×
“A comparison between CDS and chopper stabilization techniques shows that CDS technique excels in a number of aspects [11].”
BackgroundA low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R., Watkins, P., Kier, R., Lovejoy, R., Black, D., Normann, R., & Solzbacher, F. (2006) · 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2006.1696288 · Cited by 731
Brockway, B. P., Mills, P. A., & Azar, S. H. (1991) · Clinical and Experimental Hypertension. Part A: Theory and Practice · doi:10.3109/10641969109042094 · Cited by 249
Whitesall, S. E., Hoff, J. B., Vollmer, A. P., & D'Alecy, L. G. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01089.2003 · Cited by 217 · cited 1×
“The most common technique for monitoring blood pressure in small laboratory animals relies on using an invasive catheter-tip transducer inserted into an artery [3] or a tail cuff device [ 4 ].”
MethodNaturally occurring variation in cardiovascular traits among inbred mouse strains
Hoit, B. D., Kiatchoosakun, S., Restivo, J., Kirkpatrick, D., Olszens, K., Shao, H., Pao, Y.-H., & Nadeau, J. H. (2002) · Genomics · doi:10.1006/geno.2002.6754 · Cited by 110 · cited 1×
“ENETIC engineering of mice DNA sequences with real-time biological information, such as blood pressure, core body temperature and bio-potential signals, has become the most critical research tool for identifying genetic variation susceptibility to diseases [ 1 ].”
MethodA High-Performance MEMS Capacitive Strain Sensing System
Suster, M. A., Guo, J. L., Chaimanonart, N., Ko, W. H., & Young, D. J. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.881489 · Cited by 98
Self-citationIn Vivo RF Powering for Advanced Biological Research
Zimmerman, M. D., Chaimanonart, N., & Young, D. J. (2006) · Conference proceedings · doi:10.1109/iembs.2006.4397954 · Cited by 39 · cited 4×
“Previous study shows that 4 MHz is an optimal frequency to obtain an efficient RF power coupling between a pair of coil inductors with the chosen geometries described in the following section [10].”
BackgroundInfluentialSelf-citationCircuitry for a wireless microsystem for neural recording microprobes
Yu, H., & Najafi, K. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2001.1019052 · Cited by 35 · cited 1×
“A conventional method of power control is to use a voltage limiter [24].”
Method
Cited by
Hong, Y. J., Jeong, H., Cho, K. W., Lu, N., & Kim, D. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201808247 · Cited by 559
Biopsy with Thermally‐Responsive Untethered Microtools
Gultepe, E., Randhawa, J. S., Kadam, S., Yamanaka, S., Selaru, F. M., Shin, E. J., Kalloo, A. N., & Gracias, D. H. (2013) · Advanced Materials · doi:10.1002/adma.201203348 · Cited by 271
Lee, S. B., Lee, H.-M., Kiani, M., Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2078814 · Cited by 220
“Thanks to the closed-loop power control mechanism, WINeR-6 is expected to maintain the power delivered to the headstage at a constant level even when the distance or alignment between the transmitter and receiver coils change due to animal movements [ 15 ], [16].”
BackgroundA batteryless energy harvesting storage system for implantable medical devices demonstrated in situ
Gall, O. Z., Meng, C., Bhamra, H., Mei, H., John, S. W. M., & Irazoqui, P. P. (2019) · Circuits, Systems, and Signal Processing · doi:10.1007/s00034-018-0915-4 · Cited by 13
Metadata
- Authors
- Cong, P., Chaimanonart, N., Ko, W. H., & Young, D. J.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2009-12
- Volume
- 44
- Issue
- 12
- Pages
- 3631-3644
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2144374842
- Cited by
- 190
- References
- 15
- FWCI
- 6.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.