A 53-nW 9.1-ENOB 1-kS/s SAR ADC in 0.13-$\mu$m CMOS for Medical Implant Devices
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This paper describes an ultra-low power SAR ADC for medical implant devices. To achieve the nano-watt range power consumption, an ultra-low power design strategy has been utilized, imposing maximum simplicity on the ADC architecture, low transistor count and matched capacitive DAC with a switching scheme which results in full-range sampling without switch bootstrapping and extra reset voltage. Furthermore, a dual-supply voltage scheme allows the SAR logic to operate at 0.4 V, reducing the overall power consumption of the ADC by 15% without any loss in performance. The ADC was fabricated in 0.13-μm CMOS. In dual-supply mode (1.0 V for analog and 0.4 V for digital), the ADC consumes 53 nW at a sampling rate of 1 kS/s and achieves the ENOB of 9.1 bits. The leakage power constitutes 25% of the 53-nW total power.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A 10-bit 50-MS/s SAR ADC With a Monotonic Capacitor Switching Procedure
Liu, C.-C., Chang, S.-J., Huang, G.-Y., & Lin, Y.-Z. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042254 · Cited by 1,329
A 6-bit 600-MS/s 5.3-mW Asynchronous ADC in 0.13-$\mu{\hbox{m}}$ CMOS
Chen, S.-W. M., & Brodersen, R. W. (2006) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.884231 · Cited by 423
A 1-V 450-nW fully integrated programmable biomedical sensor interface chip.
Zou, X., Xu, X., Yao, L., & Lian, Y. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2014707 · Cited by 414 · cited 1×
“Therefore, Table III compares the measurement results of this work to previously published SAR ADCs with comparable sampling rates [28]–[30].”
ResultA very low-power CMOS mixed-signal IC for implantable pacemaker applications
Wong, L. S. Y., Hossain, S., Ta, A., Edvinsson, J., Rivas, D. H., & Naas, H. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.837027 · Cited by 395
Saberi, M., Lotfi, R., Mafinezhad, K., & Serdijn, W. A. (2011) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2011.2107214 · Cited by 236 · cited 1×
“In addition, to meet the linearity requirements, the total capacitance (and the power consumption) of the split architecture can be comparable to those of a conventional binary-weighted structure [16].”
Method
Cited by
(2012) · DiVA (Linkoping University) · Cited by 10
Metadata
- Authors
- Zhang, D., Bhide, A., & Alvandpour, A.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2012-07
- Volume
- 47
- Issue
- 7
- Pages
- 1585-1593
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2096069978
- Cited by
- 225
- References
- 5
- FWCI
- 12.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.