The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
A mm-Sized Implantable Medical Device (IMD) With Ultrasonic Power Transfer and a Hybrid Bi-Directional Data Link
Abstract
A first proof-of-concept mm-sized implantable device using ultrasonic power transfer and a hybrid bi-directional data communication link is presented. Ultrasonic power transfer enables miniaturization of the implant and operation deep inside the body, while still achieving safe and high power levels (100 μW to a few mWs) required for most implant applications. The current implant prototype measures 4 mm ×7.8 mm and is comprised of a piezoelectric receiver, an IC designed in 65 nm CMOS process and an off-chip antenna. The IC can support a maximum DC load of 100 μW for an incident acoustic intensity that is ~ 5% of the FDA diagnostic limit. This demonstrates the feasibility of providing further higher available DC power, potentially opening up new implant applications. The proposed hybrid bi-directional data link consists of ultrasonic downlink and RF uplink. Falling edge of the ultrasound input is detected as downlink data. The implant transmits an ultra-wideband (UWB) pulse sequence as uplink data, demonstrating capability of implementing an energy-efficient M-ary PPM transmitter in the future.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This implant supported a DC load up to 100 μW, suggesting the feasibility for higher available DC power levels between 100 μW to a few mWs (Charthad et al., 2015).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Charthad et al., 2015
In the citing paper
“For example researchers at Stanford University featured an implant with dimensions of 4 mm × 7.8 mm that operated at an incident acoustic intensity within 5% of the FDA diagnostic limit.”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Charthad et al., 2015
In the citing paper
“This implant supported a DC load up to 100 μW, suggesting the feasibility for higher available DC power levels between 100 μW to a few mWs (Charthad et al., 2015).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Charthad et al., 2015
Citations
Cites
Antenna theory, analysis, and design
Croswell, W. F. (1982) · IRE Transactions on Telemetry and Remote Control · doi:10.1109/map.1982.27654 · Cited by 8,633
Gabriel, S., Lau, R.-W.-M., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,487
Dickson, J. F. (1976) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1976.1050739 · Cited by 1,692
Acoustic waves : devices, imaging, and analog signal processing
Kino, G. S. (1987) · Prentice Hall eBooks · Cited by 1,284
Fundamental Limitations of Small Antennas
Wheeler, H. A. (1947) · Proceedings of the IRE · doi:10.1109/jrproc.1947.226199 · Cited by 1,244
Analysis and Optimization of Switched-Capacitor DC–DC Converters
Seeman, M. D., & Sanders, S. R. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915182 · Cited by 1,059
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
A jump-start for electroceuticals
Famm, K., Litt, B., Tracey, K. J., Boyden, E. S., & Slaoui, M. (2013) · Nature · doi:10.1038/496159a · Cited by 554
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488
Capsule Endoscopy: From Current Achievements to Open Challenges
Ciuti, G., Menciassi, A., & Dario, P. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2171182 · Cited by 467
Flagged first, then by citations
Research works printed but not linked: 4
- 2008, ?Information for manufacturers seeking marketing clearance of diagnostic ultrasound systems and transducers ?
- 2005, IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields 3 kHz to 300 GHz
- 1996, ?Guidelines for evaluating the environmental effects of radio frequency radiation ?
- 2013, Hybrid communication system for implantable devices and ultra-low power sensors based on U S Provisional Patent Application No 61822763
Cited by
Sorted by citations
Items 201–245 of 245
Shukla, G., Awasthi, V., Goswami, P., & Singh, S. (2024) · IEEE International Conference on Sustainable Energy and Future Electric Transportation (SEFET) · doi:10.1109/sefet61574.2024.10718219 · Cited by 2
Trade-Offs Between Data and Power Transfer in Near-Field Inductive Links
Dehghanzadeh, P., Zamani, H. A., & Mandal, S. (2019) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2019.8885173 · Cited by 2
“Various telemetry methods based on ultrasonic [1], capacitive [2], and inductive [3] links have been studied for meeting the requirements of such simultaneous wireless information and power transfer (SWIPT) applications.”
BackgroundDesign of Ceramic Packages for Acoustically Coupled Implantable Medical DevicesPreprint
Shen, K., & Maharbiz, M. M. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/836312 · Cited by 2
“to the improved efficiency of acoustic propagation in tissue over electromagnetic propagation [15-17].”
BackgroundNeural Dust: Ultrasonic Biological Interface
Seo, D. (2016) · eScholarship (California Digital Library) · Cited by 2
Bi-Phasic Quasistatic Brain Communication for Fully Untethered Connected Brain ImplantsPreprint
Chatterjee, B., Nath, M., Kumar, K. G., Xiao, S., Jayant, K., & Sen, S. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.05.10.491180 · Cited by 2
Rosa, B. M. G., & Mitcheson, P. D. (2025) · IEEE Wireless Power Technology Conference and Expo (WPTCE) · doi:10.1109/wptce62521.2025.11062276 · Cited by 1
“For continuous device operation, other powering strategies need to be explored in close proximity to the human body in the form of electromagnetic [7, 8] or ultrasonic waves [9, 10].”
Bulk- Current-Regulated Rectifier for Battery-less Ultrasound-Powered Implantable Medical Devices
Shah, M. O., Privitera, M., Grasso, A. D., & Pennisi, S. (2025) · Conference on Ph.D. Research in Microelectronics and Electronics · doi:10.1109/prime66228.2025.11203300 · Cited by 1
“Ultrasound wireless power transfer (US-WPT) has gained traction as a promising alternative to traditional electromagnetic techniques, due to its higher permissible power density in biological tissues, reduced attenuation, and deeper penetration capabilities [1], [2].”
Ultrasound in medicine from 2014 to 2024: A bibliometric review
Chenhao, Z., Ruqi, Z., Xiaozhuo, S., Jiabo, W., Jiao, L., & Yajuan, M. (2026) · Medicine · doi:10.1097/md.0000000000046890 · Cited by 1
“[25] The future research agenda should prioritize the enhancement of accuracy and resolution in medical imaging technology, alongside further exploration of deep learning algorithms for precise disease diagnosis in medical image analysis.”
Electrical powering techniques to implantable medical devices: A comprehensive survey
Uddin, M. S., & Rahman, M. A. (2026) · Next research. · doi:10.1016/j.nexres.2026.101339 · Cited by 1
Li, X., Peng, W., Kumar, L., Zhao, X., Huang, C., & Du, S. (2026) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc49663.2026.11409217 · Cited by 1
Wang, Y., Tian, J., Xu, Z., Zhang, C., Wu, J., Liu, M., Ye, Z., & Zhang, X. (2026) · Advanced Science · doi:10.1002/advs.75833 · Cited by 1
A low-power impulse radio ultra-wideband (IRUWB) transmitter for biomedical sensor applications
Mahbub, I., & ISLAM, S. K. (2017) · United States National Committee of URSI National Radio Science Meeting · doi:10.1109/usnc-ursi-nrsm.2017.7878307 · Cited by 1
“A cascoded class-A topology is chosen for the buffer stage with proper sizing of the M4 transistor [4].”
BackgroundBidirectional Parallel Capacitive Data Links: Modeling and Experimental Results
Sawma, C., Hassan, A., Kassem, A., Al-Maadeed, S. A., & Sawan, M. (2018) · IEEE Access · doi:10.1109/access.2018.2817583 · Cited by 1
“During the past decade, many wireless data telemetries emerged and have been implemented in biomedical implants including the inductive link [3]–[7], optical link [8]–[12], ultrasonic link [13], [14], radio frequency link [4], [15]–[17] and capacitive link [2], [18]–[21].”
BackgroundThe Implantable Internet of Medical Things
Guida, R., Dave, N., Restuccia, F., Demirors, E., & Melodia, T. (2021) · GetMobile Mobile Computing and Communications · doi:10.1145/3447853.3447861 · Cited by 1
“Despite the numerous recent advances in intra-body communications and implantable medical devices (IMDs), most of the existing devices focus on small-scale ad hoc design, wireless charging, passive communications and extremely low power consumption [1, 2, 3, 17], while other platforms [15] focus on the computation/com…”
BackgroundUltrasonic Wireless Neural Recording and Stimulation Interfaces
Sonmezoglu, S., Shen, K., Carmena, J. M., & Maharbiz, M. M. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_10-2 · Cited by 1
Ultrasound transducer optimization for wireless battery charging in subcutaneous implantable device
Hoang, T., Rosinski, B., & Félix, N. (2022) · IEEE International Ultrasonics Symposium · doi:10.1109/ius54386.2022.9957147 · Cited by 1
“Acoustic power transfer exhibits a great potential compared to other techniques in terms of efficiency, miniaturization and can delivery energy deeper inside the body [5].”
BackgroundElectrodynamic Wireless Power and Data Transfer for Implanted Medical Devices
Barrett, C., Fu, H., & Theodossiades, S. (2023) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors56945.2023.10325056 · Cited by 1
“…field capacitive coupling [7], inductive coupling [8] (as used in short range implants e.g. muscle stimulators or cochlear implants [1]) and ultrasonic wireless power transfer (WPT) [9] [10] [11], which is more efficient compared to inductive methods over longer ranges with smaller receivers [12].”
BackgroundFeasibility analysis of wireless power delivery to implanted sensors of XLIF patients
Mukhopadhyay, S., Senn, I., Ramakrishna, V. A. S., George, B., Prusty, G., & Diwan, A. (2024) · International Journal on Smart Sensing and Intelligent Systems · doi:10.2478/ijssis-2024-0028
Millimeter-scale radioluminescent power for electronic sensors
Kandala, A., Wang, S., Blecha, J. E., Wang, Y.-H., Lall, R. K., Niknejad, A. M., Seo, Y., Evans, M. J., Flavell, R. R., VanBrocklin, H. F., et al. (2024) · iScience · doi:10.1016/j.isci.2024.111686 · Cited by 1
International Congress on Renewable Energy (I CORE 2021)
Subburaj, V., Dash, R. K., Reddy, J., & Raghu, C. N. (2022) · doi:10.13052/rp-9788770227537 · Cited by 1
A Micro-Scale Mobile-Enabled Implantable Medical SensorPreprint
Okwori, M., Behfarnia, A., Vuka, P., & Eslami, A. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1806.06163 · Cited by 1
“2 mW/mm2 for diagnostic ultrasound applications [10], [17], [18], which is about two orders of magnitude higher than the safe RF exposure limit in the body (10 − 100 μW/mm2 [28], [29]).”
McCormick, D. (2020) · doi:10.36227/techrxiv.12656078.v1 · Cited by 1
Liu, C., Ren, Z., Li, M., Ge, W., Wu, C., Zhou, L., Tang, L., Zhao, H., & Ren, L. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4822907 · Cited by 1
Becerra-Fajardo, L. (2016) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Neely, R. (2017) · eScholarship (California Digital Library)
RF power transmission and its considerations for ECoG implants
Ha, S., Kim, C., Mercier, P. P., & Cauwenberghs, G. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815115-0.00013-1
Power management for mm-sized ECoG implants
Ha, S., Kim, C., Mercier, P. P., & Cauwenberghs, G. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815115-0.00012-x
A Current-Switching Communication Technique for Miniaturized Medical Implants
Wang, W., Tian, M. L., Zhang, H., & Zhao, B. (2019) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2019.8918683
“The transducer in ultrasonic WPT requires special devices, such as a disk-shaped piezoelectric device in [7], leading to smaller implant size but high hardware cost [7], [8].”
MethodSelf Capacitance based Wireless Power Transfer for Wearable Electronics: Theory and Implementation
Alazzawi, Y. (2020) · Open Scholarship Institutional Repository (Washington University in St. Louis) · doi:10.7936/qzd7-x730
Demonstration of Healthcare-Specific Li-ion Battery Charging Using Ultrasound Power Delivery
Makin, I. R. S., Jabs, H., Mast, T. D., & Radziemski, L. J. (2021) · IEEE Wireless Power Transfer Conference · doi:10.1109/wptc51349.2021.9458228
“Most of the ultrasound powering examples in the literature mainly report delivery of low-level power (order of mW) several cm deep in the body [4-7],”
BackgroundUltrasound Mediated Wireless Power Transfer Technology
Hur, S., Kim, H. S., & Song, H. (2021) · Ceramist · doi:10.31613/ceramist.2021.24.3.05
State-of-the-Art Technology on Highly Miniaturized Free-Floating Neural Implants
Khalifa, A., & Etienne‐Cummings, R. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_114-1
A novel closed-loop BCI system based on comparison of multiple methods (Withdrawal Notice)
Ai, Y. (2022) · International Conference on Computer, Artificial Intelligence and Control Engineering (CAICE) · doi:10.1117/12.2641147
“…chosen since it offers various advantages: (1) energy is focused to a mm size spot at a specific depth (> 10 cm)[30], (2) high transfer efficiency[31], (3)low tissue attenuation (0.5–1 dB/cm/MHz)[32], and the frequency-depth characteristics of multiple field stimulation designs are shown in the…”
BackgroundInfluentialSegmentasi Citra Grayscale Dengan Metode K-Means Clustering gerak tangan bahasa isyarat indonesia
Betty, M. Y., Iskandar, D. M., & Franido, R. (2022) · Smart Comp Jurnalnya Orang Pintar Komputer · doi:10.30591/smartcomp.v11i4.4243
“[10] R merupakan project open-sourceyangmemungkinkan banyak pihak untuk memberikan kontribusi dalam proses pengembangan.[11] Dalam penelitian ini, penulis menggunakan jpeg package untuk memudahkan dalam pembacaan data citra.”
BackgroundOptimal Frequency for Biomedical Wireless Power TransferPreprint
van Nunen, T., Mestrom, R., & Visser, H. J. (2023) · Research Square · doi:10.21203/rs.3.rs-3527426/v1
Zhang, B., Cui, J., Qi, B., Wang, Z., Zheng, Y., & Xue, C. (2025) · Lecture notes in electrical engineering · doi:10.1007/978-981-96-1852-1_56
A 16.4pJ/bit Fully Integrated IR-UWB Transmitter with PSK+PPM Modulation and On-Chip Antenna
Li, M., Zhang, X., You, C., Liu, Y., Yao, W., Wu, T., & Yao, L. (2025) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas56072.2025.11044040
Fully Integrated Ultrasound Power Receiver for Multi-Piezo Implants with Random Phase Offset
Kumar, L., Du, S., & Muratore, D. G. (2025) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas56072.2025.11043231
Settia, N., Shreenidhi, K. S., Anandaram, H., Maurya, R., Goel, V., Kaur, G., & Bhutani, M. (2025) · Lecture notes in networks and systems · doi:10.1007/978-981-96-6681-2_7
Shape-engineered BaTiO3 receivers for ultrasonic powering of modular localized peritumoral therapies
Selvarajan, S., Qasim, R., Yang, Y., Kim, J. K., Yang, Z., & Kim, A. (2025) · Nano Energy · doi:10.1016/j.nanoen.2025.111672
Xu, M., Zhang, T., Lin, Y., Jin, T., Yan, C., Gao, H., Liu, X. S., & Li, Z. F. (2026) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas66217.2026.11562520
Gao, C., Chen, W., Li, Z., Lan, Y., Zhang, C., Li, Y., Lu, Y., Lin, L., & Li, J. (2026) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2026.3690876
“In contrast, ultrasound has emerged as a promising solution [21], [22], [23], [24], [25], [26], [27], [28], [29], [30], [31], [32], [33], [34], [35], thanks to its low tissue attenuation, relatively high FDA power limits (7.2 mW / mm 2 ) [21], and sub-millimeter beam [22].”
InfluentialAdvances in Electromagnetic Compatibility for Biomedical Wearable and Implantable Devices
Liu, K., Xu, G., & Geng, D. (2026) · doi:10.1109/apemc65388.2026.11593641
“Furthermore, alternative modalities such as ultrasonic WPT and biomechanical energy harvesting offer viable solutions for deep-tissue focusing and self-powering applications, respectively [10] .”
An in-body networking system for communication between wearable and implantable therapeutics
Ghanim, R. W., Lee, Y. J., Byun, G., Jackson, J. M., Ding, J. Z., Park, J., Bibidakis, M., Feller, E., Kim, E., Aygun, D., et al. (2026) · Science · doi:10.1126/science.adz5300 · Cited by 1
Metadata
- Authors
- Charthad, J., Weber, M. J., Chang, T. C., & Arbabian, A.
- Affiliations
- Stanford University (US)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2015-08
- Volume
- 50
- Issue
- 8
- Pages
- 1741-1753
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W1583855207
- Cited by
- 245
- References
- 40
- Citations by year
- 2026: 10 · 2025: 18 · 2024: 22 · 2023: 23 · 2022: 20 · 2021: 31 · 2020: 31 · 2019: 20 · 2018: 27 · 2017: 24 · 2016: 17 · 2015: 2
- FWCI
- 11.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- biomedical implants, ultrasonic power transfer, piezoelectric receiver, M-ary pulse position modulation, energy-efficient transmitter, 65 nm CMOS, device miniaturization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review