The DOI matches its Crossref record; 147 of the 148 references it cites were found in a registry or an index.
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Abstract
Neural interfaces are connections that enable two-way exchange of information with the nervous system. These connections can occur at multiple levels, including with peripheral nerves, with the spinal cord, or with the brain; in many instances, fundamental biophysical and biological challenges are shared across these levels. We review these challenges, including selectivity, stability, resolution versus invasiveness, implant-induced injury, and the host-interface response. Subsequently, we review the engineered solutions to these challenges, including electrode designs and geometry, stimulation waveforms, materials, and surface modifications. Finally, we consider emerging opportunities to improve neural interfaces, including cellular-level silicon to neuron connections, optical stimulation, and approaches to control inflammation. Overcoming the biophysical and biological challenges will enable effective high-density neural interfaces for stimulation and recording.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Communication within the nervous system is primarily through the rate and pattern of action potentials, and it is the number or spacing of these action potentials per unit time that code information. Thus, information can be introduced into the nervous system by inducing action potentials, or these action potentials can be read to obtain information from the nervous system [14].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [14]
In the citing paper
“Peripheral nerve implants can also result in peripheral nerve injury. This can lead to Wallerian degeneration, neuropathic pain, and fibrosis, resulting in signal loss [14].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [14]
In the citing paper
“The reported number of sensory perceptions and the locations evoked by intra-neural interfaces are very similar to those of the long-term extra-neural approaches, which led Grill et al. (2009) to conclude that the two approaches are equivalent.”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Grill et al. (2009)
In the citing paper
“A ramp pulse can be used to activate distal axons before closer ones (Grill and Mortimer, 1997; Grill et al., 2009)”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Grill et al., 2009
In the citing paper
“Hence, new therapeutic strategies for treating various refractory diseases through electrode-nerve interfaces have been developed, such as motor nerve stimulation and recording for controlling prosthetics and vagus nerve stimulation (VNS) for treating partial epilepsy, depression, heart failure (HF), and hypertension (1, 2).”
From Climbing-inspired twining electrodes using shape memory for peripheral nerve stimulation and recording (2019) · cites this paper as [2]
Citations
Cites
(1982) · Trends in Neurosciences · doi:10.1016/0166-2236(82)90076-5 · Cited by 9,089
Microglia-mediated neurotoxicity: uncovering the molecular mechanisms
Block, M. L., Zecca, L., & Hong, J.-S. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2038 · Cited by 4,110
Deep Brain Stimulation for Treatment-Resistant Depression
Mayberg, H. S., Lozano, A. M., Voon, V., McNeely, H. E., Seminowicz, D., Hamani, C., Schwalb, J. M., & Kennedy, S. H. (2005) · Neuron · doi:10.1016/j.neuron.2005.02.014 · Cited by 4,059
Henry, M. A. (1995) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1995.0108 · Cited by 3,416
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Regeneration beyond the glial scar
Silver, J., & Miller, J. H. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1326 · Cited by 3,078
Taussig, M. (2012) · Routledge eBooks · doi:10.4324/9780203397244 · Cited by 2,532
Krack, P., Batir, A., Van Blercom, N., Chabardes, S., Fraix, V., Ardouin, C., Koudsie, A., Limousin, P. D., Benazzouz, A., LeBas, J. F., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035275 · Cited by 2,249
Society for Neuroscience 2007 abstracts
Wishart, T. M., Paterson, J. M., Short, D. M., Meredith, S., Robertson, K., Sutherland, C. D., Cousin, M. A., Dutia, M. B., & Gillingwater, T. H. (2007) · Cited by 2,094
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Research works printed but not linked: 8
- Vallbo AB, 1984, Hum. Neurobiol., 3, 3
- 10.1002/(SICI)1097-4636(200005)50:2<215::AID-JBM17>3.0.CO;2-A · doi:10.1002/(sici)1097-4636(200005)50:2<215::aid-jbm17>3.0.co;2-a
- Rydevik B, 1990, Neural Prostheses Fundamental Studies, 85
- Hoffer JA, 1996, J. Rehabil. Res. Dev., 33, 145
- Bellamkonda RV, 2006, Biomaterials, 27, 3515
- Frosch MP, 2007, Basic Pathology
- 85. Deleted in press
- Shain W, 2003, IEEE Trans. Biomed. Eng., 11, 186
Cited by
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Enhanced Differentiation of Human Neural Stem Cells into Neurons on Graphene
Park, S. Y., Park, J., Sim, S. H., Sung, M. G., Kim, K. S., Hong, B. H., & Hong, S. (2011) · Advanced Materials · doi:10.1002/adma.201101503 · Cited by 703
Metadata
- Authors
- Grill, W. M., Norman, S. E., & Bellamkonda, R. V.
- Affiliations
- Duke University (US)
- Georgia Institute of Technology (US)
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2009-08-01
- Volume
- 11
- Issue
- 1
- Pages
- 1-24
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2118756387
- Cited by
- 488
- References
- 148
- Citations by year
- 2026: 14 · 2025: 15 · 2024: 26 · 2023: 31 · 2022: 24 · 2021: 39 · 2020: 37 · 2019: 43 · 2018: 35 · 2017: 43 · 2016: 34 · 2015: 35 · 2014: 25 · 2013: 29 · 2012: 17
- FWCI
- 1.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Annual Review of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- neural interfaces, neural recording, neurostimulation, electrode design, electrode geometry, stimulation waveform, implant materials, surface modification, selectivity, peripheral nerves, spinal cord, optical stimulation, inflammation control
- MeSH terms
- Animals, Biophysics, Electric Stimulation, Electrodes, Implanted, Ganglia, Spinal, Humans, Inflammation, Models, Biological, Models, Neurological, Nerve Net, Neurons, Peripheral Nervous System, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implanted Neural Interfaces: Biochallenges and Engineered Solutions. https://app.cochat.ai/papers/10.1146/annurev-bioeng-061008-124927
- The paper
- Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009). Implanted Neural Interfaces: Biochallenges and Engineered Solutions. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev-bioeng-061008-124927
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.