The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
A Fully Integrated 8-Channel Closed-Loop Neural-Prosthetic CMOS SoC for Real-Time Epileptic Seizure Control
Abstract
An 8-channel closed-loop neural-prosthetic SoC is presented for real-time intracranial EEG (iEEG) acquisition, seizure detection, and electrical stimulation in order to suppress epileptic seizures. The SoC is composed of eight energy-efficient analog front-end amplifiers (AFEAs), a 10-b delta-modulated SAR ADC (DMSAR ADC), a configurable bio-signal processor (BSP), and an adaptive high-voltage-tolerant stimulator. A wireless power-and-data transmission system is also embedded. By leveraging T-connected pseudo-resistors, the high-pass (low-pass) cutoff frequency of the AFEAs can be adjusted from 0.1 to 10 Hz (0.8 to 7 kHz). The noise-efficiency factor (NEF) of the AFEA is 1.77, and the DMSAR ADC achieves an ENOB of 9.57 bits. The BSP extracts the epileptic features from time-domain entropy and frequency spectrum for seizure detection. A constant 30- μA stimulus current is delivered by closed-loop control. The acquired signals are transmitted with on-off keying (OOK) modulation at 4 Mbps over the MedRadio band for monitoring. A multi-LDO topology is adopted to mitigate the interferences across different power domains. The proposed SoC is fabricated in 0.18- μm CMOS and occupies 13.47 mm2. Verified on Long Evans rats, the proposed SoC dissipates 2.8 mW and achieves high detection accuracy (> 92%) within 0.8 s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Approximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Kwan, P., Schachter, S. C., & Brodie, M. J. (2011) · New England Journal of Medicine · doi:10.1056/nejmra1004418 · Cited by 1,052
Arroyo, S., Rumià, J., Martínez, I., & Ribalta, T. (1998) · PubMed · Cited by 652
Verma, N., Shoeb, A., Bohorquez, J., Dawson, J., Guttag, J., & Chandrakasan, A. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042245 · Cited by 526
Closed-Loop Control of Epilepsy by Transcranial Electrical Stimulation
Berényi, A., Belluscio, M., Mao, D., & Buzsáki, G. (2012) · Science · doi:10.1126/science.1223154 · Cited by 476
Yoo, J., Yan, L., El-Damak, D., Altaf, M. A. B., Shoeb, A. H., & Chandrakasan, A. P. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2012.2221220 · Cited by 274
Guo, S., & Lee, H. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2020195 · Cited by 253
Thermal Impact of an Active 3-D Microelectrode Array Implanted in the Brain
Kim, S., Tathireddy, P., Normann, R. A., & Solzbacher, F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.908429 · Cited by 214
Cited by
Chandrakumar, H., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2645611 · Cited by 237
A mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves
Charthad, J., Chang, T. C., Liu, Z., Sawaby, A., Weber, M. J., Baker, S., Gore, F., Felt, S. A., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2799623 · Cited by 230
Jiang, W., Hokhikyan, V., Chandrakumar, H., Karkare, V., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2624989 · Cited by 140
Kim, C., Joshi, S., Courellis, H., Wang, J., Miller, C., & Cauwenberghs, G. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2870555 · Cited by 104
A 1-V 0.25- $\mu \text{W}$ Inverter Stacking Amplifier With 1.07 Noise Efficiency Factor
Shen, L., Lu, N., & Sun, N. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2786724 · Cited by 101
Metadata
- Authors
- Chen, W.-M., Chiueh, H., Chen, T.-J., Ho, C.-L., Jeng, C., Ker, M.-D., Lin, C.-Y., Huang, Y.-C., Chou, C.-W., Fan, T.-Y., Cheng, M.-S., Hsin, Y.-L., Liang, S.-F., Wang, Y.-L., Shaw, F.-Z., Huang, Y.-H., Yang, C.-H., & Wu, C.-Y.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2014-01
- Volume
- 49
- Issue
- 1
- Pages
- 232-247
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W2122982148
- Cited by
- 279
- References
- 31
- FWCI
- 12.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Fully Integrated 8-Channel Closed-Loop Neural-Prosthetic CMOS SoC for Real-Time Epileptic Seizure Control. https://app.cochat.ai/papers/10.1109/jssc.2013.2284346
- The paper
- Chen, W.-M., Chiueh, H., Chen, T.-J., Ho, C.-L., Jeng, C., Ker, M.-D., Lin, C.-Y., Huang, Y.-C., Chou, C.-W., Fan, T.-Y., Cheng, M.-S., Hsin, Y.-L., Liang, S.-F., Wang, Y.-L., Shaw, F.-Z., Huang, Y.-H., Yang, C.-H., & Wu, C.-Y. (2014). A Fully Integrated 8-Channel Closed-Loop Neural-Prosthetic CMOS SoC for Real-Time Epileptic Seizure Control. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2013.2284346
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.