Track-and-Zoom Neural Analog-to-Digital Converter With Blind Stimulation Artifact Rejection
The DOI matches its Crossref record; 44 of the 45 references it cites were found in a registry or an index.
Abstract
Closed-loop neuromodulation for the treatment of neurological disorders requires monitoring of the brain activity uninterruptedly even during neurostimulation. This article presents a bidirectional 32-channel CMOS neural interface that can record neural activity during stimulation. Each channel consists of a dc-coupled Δ2Σ-modulated analog-to-digital converter (neural-ADC), which records slow potentials (2Σ-ADC consumes 1.7 μW from 0.6-V/1.2-V digital/analog supplies and time-shares the modulator's feedback DAC as the multi-bit current-mode stimulator operating at 3.3 V. The ADC occupies a silicon area of 0.023 mm2in the 130-nm CMOS and achieves a signal-to-noise-and-distortion ratio (SNDR) of 70 dB over the 500-Hz bandwidth and an equivalent noise efficiency factor (NEF) of 2.86 without a stand-alone front-end amplifier. The 32-channel bidirectionally interfacing prototype is validated in the in vivo whole brain of a rodent.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Track-and-zoom (TAZ) enables automatic detection of artifacts based on the occurrence of amplifier saturation, enabling the rapid adjustment of the input range without the need for synchronisation with the stimulation outputs [189].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [189]
In the citing paper
“There are three categories of artifact suppression techniques in bidirectional interface systems [188], [189].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [189]
In the citing paper
“A track-and-zoom (TAZ) neural ADC is proposed in Reza Pazhouhandeh et al. (2020).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Reza Pazhouhandeh et al., 2020
In the citing paper
“When fast artifact transients are detected, the multi-bit DAC will feedback to the TAZ ADC.”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Reza Pazhouhandeh et al., 2020
In the citing paper
“As shown in Figure 4F, a recording amplifier and an ADC are combined.”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Reza Pazhouhandeh et al., 2020
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Understanding Delta‐Sigma Data Converters
Schreier, R., Pavan, S., & Temes, G. C. (2017) · Wiley eBooks · doi:10.1002/9781119258308 · Cited by 1,965
Adaptive deep brain stimulation in advanced Parkinson disease.
Little, S., Pogosyan, A., Neal, S., Zavala, B., Zrinzo, L., Hariz, M., Foltynie, T., Limousin, P., Ashkan, K., FitzGerald, J., et al. (2013) · Annals of Neurology · doi:10.1002/ana.23951 · Cited by 1,374
Responsive cortical stimulation for the treatment of medically intractable partial epilepsy
Morrell, M. J. (2011) · Neurology · doi:10.1212/wnl.0b013e3182302056 · Cited by 1,282 · cited 1×
“For example, responsive cortical neurostimulation can abort an epileptic seizure by delivering therapeutic stimulation waveforms after seizure precursors’ detection [4]–[8], and closed-loop deep brain stimulation (DBS) is promising in treating Parkinson’s disease or other motor disorders [9], [10].”
BackgroundClosed-Loop Deep Brain Stimulation Is Superior in Ameliorating Parkinsonism
Rosin, B., Slovik, M., Mitelman, R., Rivlin-Etzion, M., Haber, S. N., Israel, Z., Vaadia, E., & Bergman, H. (2011) · Neuron · doi:10.1016/j.neuron.2011.08.023 · Cited by 793
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Understanding delta-sigma data converters
(2005) · Choice Reviews Online · doi:10.5860/choice.42-4688 · Cited by 791 · cited 1×
“As such, a second-order modulator with two integrators might consume up to 15% more power depending on the scaling factor of the second-stage amplifier if a 10× scaling factor were applied [30].”
BackgroundHeck, C. N., King‐Stephens, D., Massey, A. D., Nair, D. R., Jobst, B. C., Barkley, G. L., Salanova, V., Cole, A. J., Smith, M. C., Gwinn, R. P., et al. (2014) · Epilepsia · doi:10.1111/epi.12534 · Cited by 651 · cited 1×
“NEURAL brain activity contains biomarkers that can be used for the detection and treatment of pathological neurological events by closed-loop neuromodulation [1]–[3].”
BackgroundThe electrical conductivity of human cerebrospinal fluid at body temperature
Baumann, S. B., Wozny, D. R., Kelly, S. K., & Meno, F. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554770 · Cited by 494 · cited 1×
“Given the impedance of cerebrospinal fluid [20] and stimulation electrodes [21], the amplitude of these artifacts can easily exceed the power-supply rail level if a unipolar (single-ended) stimulation method with a high stimulation current is used.”
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451
Sources and effects of electrode impedance during deep brain stimulation
Butson, C. R., Maks, C. B., & McIntyre, C. C. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.10.007 · Cited by 360 · cited 1×
“Given the impedance of cerebrospinal fluid [20] and stimulation electrodes [21], the amplitude of these artifacts can easily exceed the power-supply rail level if a unipolar (single-ended) stimulation method with a high stimulation current is used.”
Cited by
Shaping high-performance wearable robots for human motor and sensory reconstruction and enhancement
Xia, H., Zhang, Y., Rajabi, N., Taleb, F., Yang, Q., Kragić, D., & Li, Z. (2024) · Nature Communications · doi:10.1038/s41467-024-46249-0 · Cited by 164
“Pazhou-handeh et al. proposed a neural ADC that achieves blind stimulation artifact rejection, where a bidirectional COMS neural interface could capture neural signals during neural stimulation 103 .”
BackgroundLee, C., Jeon, T., Jang, M., Park, S., Kim, J., Lim, J., Ahn, J., Huh, Y., & Chae, Y. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3018478 · Cited by 114
“digitization topologies replacing the conventional combination of IA and ADC have become increasingly popular [11]–[17].”
BackgroundPu, H., Malekzadeh-Arasteh, O., Danesh, A. R., Nenadić, Z., Do, A. H., & Heydari, P. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3108578 · Cited by 79
A Patient-Specific Closed-Loop Epilepsy Management SoC With One-Shot Learning and Online Tuning
Zhang, M., Zhang, L., Tsai, C.-W., & Yoo, J. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3144460 · Cited by 62
A Bidirectional Neural Interface SoC With Adaptive IIR Stimulation Artifact Cancelers
Samiei, A., & Hashemi, H. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3056040 · Cited by 49
Jung, Y., Kweon, S.-J., Jeon, H., Choi, I., Koo, J., Kim, M. K., Lee, H. J., Ha, S., & Je, M. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3188626 · Cited by 50
“…V pp , maintaining good SNDR performance over 50 dB. Defining DR as the input power range over which the SNDR larger than 50 dB is maintained [26], [29], [30], the AGC and OSR adjustment operations enhance the DR performance of the proposed IC by more than 30 dB compared with the case using a fixed…”
MethodResultWendler, D., Dorigo, D. D., Amayreh, M., Bleitner, A., Marx, M., Willaredt, R., & Manoli, Y. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3190446 · Cited by 50
Pochet, C., Huang, J., Mercier, P. P., & Hall, D. A. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3133531 · Cited by 47
“Several designs have achieved the necessary DR for wearable applications [1], [14], [17]; however, they typically do not have”
BackgroundA High-Voltage Compliance, 32-Channel Digitally Interfaced Neuromodulation System on Chip
Reich, S., Sporer, M., Haas, M., Becker, J., Schüettler, M., & Ortmanns, M. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3076510 · Cited by 43
“It is slightly outperformed by designs [26]–[28], which are all implemented in the smaller 130 nm CMOS node but also use very low analog supply voltages of typically 1.”
BackgroundBrain–computer interfaces in 2023–2024
Chen, S., Chen, M., Wang, X., Liu, X., Liu, B., & Ming, D. (2025) · Brain‐X · doi:10.1002/brx2.70024 · Cited by 52
An AC-Coupled 1st-Order Δ-ΔΣ Readout IC for Area-Efficient Neural Signal Acquisition
Yang, X., Ballini, M., Sawigun, C., Hsu, W.-Y., Weijers, J.-W., Putzeys, J., & López, C. M. (2023) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2023.3234612 · Cited by 46
“It is clear from the table that lower bandwidth designs [28], [33] are optimized to achieve very low noise and power at the expense of area.”
BackgroundMethodOpamp-Less Sub-μW/Channel Δ-Modulated Neural-ADC With Super-GΩ Input Impedance
Pazhouhandeh, M. R., Kassiri, H., Shoukry, A., Weisspapir, I., Carlen, P. L., & Genov, R. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3041289 · Cited by 42
“However, it achieves a higher SQNR at lower OSRs compared with - and non-quantization-noise shaping ADCs by more than 30 dB due to the spectrum equalization [26], [34], [35].”
BackgroundMethodSelf-citationA Compact Chopper Stabilized Δ-ΔΣ Neural Readout IC With Input Impedance Boosting
Wang, S., Ballini, M., Yang, X., Sawigun, C., Weijers, J.-W., Biswas, D., Helleputte, N. V., & López, C. M. (2021) · IEEE Open Journal of the Solid-State Circuits Society · doi:10.1109/ojsscs.2021.3113887 · Cited by 38
“Although small area has also been achieved in several low-frequency readouts [21], [22], [29]–[31], those architectures cannot be easily extrapolated to the larger bandwidth and higher electrode impedance required for AP recording.”
BackgroundFathy, N. S. K., Huang, J., & Mercier, P. P. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3116021 · Cited by 34
Aslam, A. R., & Altaf, M. A. B. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3113613 · Cited by 35
Jeong, K., Ha, S., & Je, M. (2023) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2023.3300928 · Cited by 28
“To address this DR limitation of the conventional biosignal acquisition ICs, various direct-conversion-based acquisition ICs have been proposed, broadening the DR at relatively low power consumption [32], [33], [34], [35], [36], [37], [38], [39], [40], [41], [42], [43].”
BackgroundInfluentialAnalog Front-End Input-Impedance Boosting Techniques for Bio-Potential Monitoring—A Review
Yan, F., & Liu, J. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3370766 · Cited by 37
“In order to acquire high-quality bioelectrical signals by AFE, a variety of solutions ranging from AE design [33], [34], [35], [36] to the subsequent IA design [37], [38], [39], [40], [41] have been proposed.”
MethodRecording Strategies for High Channel Count, Densely Spaced Microelectrode Arrays
Pérez-Prieto, N., & Delgado‐Restituto, M. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.681085 · Cited by 26
Reich, S., Sporer, M., & Ortmanns, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3080398 · Cited by 23
“The design reported in [25] combines very good area and power consumption with low noise, but does not feature full-band recording.”
BackgroundFrom Wearables to Implantables: Harnessing Sensor Technologies for Continuous Health Monitoring
Koruprolu, A., Hack, T., Ghadami, O., Jain, A., & Hall, D. A. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3568754 · Cited by 25
“6(c) and 6(d), have faster recovery times to motion and stimulation artifacts [156], [157], [158], [159], [160], [161], [162], [163].”
Adaptively Clock-Boosted Auto-Ranging Neural-Interface for Emerging Neuromodulation Applications
Pazhouhandeh, M. R., Amirsoleimani, A., Weisspapir, I., Carlen, P. L., & Genov, R. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3223988 · Cited by 22
“artifacts leveraging a predictive auto-ranging mechanism in the feedback digital to analog converter (DAC) [12], [15].”
BackgroundMethodSelf-citationAdvances in Neural Recording and Stimulation Integrated Circuits
Li, J., Liu, X., Mao, W., Chen, T., & Yu, H. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.663204 · Cited by 21
“A track-and-zoom (TAZ) neural ADC is proposed in Reza Pazhouhandeh et al. (2020).”
BackgroundQiu, Z., Nguyen, A. T., Su, K., Yang, Z., & Xu, J. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3321295 · Cited by 21
An 800MΩ-Input-Impedance 95.3dB-DR Δ-ΔΣ AFE for Dry-Electrode Wearable EEG Recording
Li, Y., Li, Y., Li, H., Hong, Z., & Xu, J. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3374891 · Cited by 21
“Since the added sigma stage in the feedback loop is implemented in the digital domain, the DEO cancellation can be rail-to-rail in theory [9], [19].”
BackgroundMethodInfluentialCho, J., Seong, G., Chang, Y., & Kim, C. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.667447 · Cited by 19
High-Precision Readout Circuits for Portable Biosensor Devices—A Review of IA
Yang, H., Yan, J., Tan, J., Ren, M., Li, X., & Wang, S. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3536079 · Cited by 18
“Many scientists have proposed a variety of innovative solutions to improve input impedance [30], [31], [32], [33], [34], and DSL technology itself is also subject to continuous change and optimization [11], [35], [36], [37].”
Jeong, K., Jung, Y., Yun, G., Youn, D., Jo, Y., Lee, H. J., Ha, S., & Je, M. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3193944 · Cited by 17
Jaber, A. S., & Idrees, A. K. (2022) · Lecture notes on data engineering and communications technologies · doi:10.1007/978-3-030-90618-4_20 · Cited by 14
Using biopotential and bio-impedance for intuitive human–robot interaction
Park, K., Jeong, H., Jung, Y., Suh, J.-H., Je, M., & Kim, J. (2025) · Nature Reviews Electrical Engineering · doi:10.1038/s44287-025-00191-5 · Cited by 13
Hao, Y., Fan, H., Lian, Y., & Chen, M. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3514745 · Cited by 13
“The internal supply for the DDA’s input is increased from 1.8 to 3.0 V (by 4.5 dB), while the dynamic range is improved by more than 20 dB compared with the state-of-the-art Direct-FE [22], [24], [31], [32].”
InfluentialOh, S., Song, H., Slager, N., Ruiz, J. R. L., Park, S., & Yoon, E. (2023) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2023.3298662 · Cited by 12
“conversion range of theΔΣmodulator [18], [19], [20].”
BackgroundMethodInfluentialActive Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
Xu, Q., Li, G., Liu, Y., Luo, F. C., & Xiao, Z. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3363130 · Cited by 11
“Various amplifier structures have been presented over the years to decrease the NEF of neural signal recording amplifier [2], [3], [4], [12], [20], [21], [22], [23], [24], [25], [26], [27], [28], [34], [35], [36], as illustrated in Fig.”
MethodLiu, H., Guo, T., Yan, P., Qi, L., Chen, M., Wang, G., & Liu, Y. (2022) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2022.3153786 · Cited by 14
“1(c), relax the DR requirement of the front end [7]–[9], however with possible integration error.”
BackgroundA VCO-Based CTDSM With Integrated Phase Error Correction for Neural Interface
Liu, H., Qi, L., Wang, G., & Liu, Y. (2022) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2022.3186788 · Cited by 10
A 101-dB DR 2.2GΩ-Input-Impedance Direct Digitization ExG Front-End With Δ-Modulation
Li, Y., Li, H., Qu, T., Liu, Q., Hong, Z., & Xu, J. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3563304 · Cited by 10
“Increasing the sampling frequency f s can also improve the AFE’s response to fast-varying artifacts and extend the input DR [19], [20].”
Jain, A., Fogleman, E., Botros, P., Vatsyayan, R., Koruprolu, A., Pochet, C., Bourhis, A. M., Liu, Z., Chethan, S., Le, H., et al. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3508544 · Cited by 9
“…in direct digitization-based AFEs overcome this artifact-related saturation limitation by forgoing the amplifier and directly connecting the electrode to a high dynamic range (DR) ADC, typically a continuous-time modulator (CT-(cid:49)(cid:54) M) [31], [32], [33], [34], [35], [36], [37], [38].”
An Active Microchannel Neural Interface for Implantable Electrical Stimulation and Recording
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3533612 · Cited by 8
Dynamic-Range-Enhancement Techniques for Artifact-Tolerant Biopotential-Acquisition ICs
Jung, Y., Kweon, S.-J., Lee, T., Jeong, K., Ha, S., & Je, M. (2022) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2022.3176272 · Cited by 9
Liu, H., Lin, Y., Qi, L., Lou, Y., Wang, G., & Liu, Y. (2022) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2022.3225559 · Cited by 9
“Compared with the high DR CTDSM [12], [17], [40], [41], high DR delta-modulator [6], [7], [9], adaptive filter assisted AFE [3] and hybrid fast feedback structure [37], the proposed front-end with the mixed domain level-crossing scheme achieves the largest artifact tolerance range and fastest…”
BackgroundMethodInfluentialJia, Y., & Zhao, L. (2023) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2023.3305589 · Cited by 7
“Therefore, researchers have proposed direct digitization AFEs (DDAFEs), eliminating the preamplifier and boosting the DR [23], [46], [47], [48], [49], [50], [51], [52], [53], [54], [55], [56], [57].”
BackgroundCircuits and Architectures for Neural Recording Interfaces
López, C. M., & Huang, X. (2023) · Springer eBooks · doi:10.1007/978-3-031-28912-5_3 · Cited by 7
Lee, S.-Y., Lee, H.-Y., Kung, C.-H., Su, P.-H., & Chen, J. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3201328 · Cited by 6
Xu, J., Kanchwala, M., Abdolrazzaghi, M., Cai, H., Huang, Y. T., Ma, J., Lim, C., Xu, L., Gong, S., Deng, W., et al. (2025) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc49661.2025.10904733 · Cited by 5
“However, the power dissipation of neural ADCs, either dedicated [9-12] or time-multiplexed [1-3,13 .”
Self-citationJung, Y., Kweon, S.-J., Jeon, H., Lee, T., Choi, I., Jeong, K., Kim, M. K., Lee, H. J., Ha, S., & Je, M. (2021) · IEEE Asian Solid-State Circuits Conference (A-SSCC) · doi:10.1109/a-sscc53895.2021.9634824 · Cited by 5
In Vitro Study of Artifact-Recovery Using a 32-Channel Neuromodulator Platform
Reich, S., Fritschi, D., Sporer, M., & Ortmanns, M. (2023) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2023.3255549 · Cited by 5
“, demonstrated in the 126 front-end in [38], achieving NEF = 2.”
BackgroundZhang, M., Zhao, Z., Ma, Y., Zhang, C., Song, W., Lei, J., & Xie, C. (2023) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2023.3312227 · Cited by 5
“Cutting-edge neural interfaces for measuring LFP signals are presented in [13], [14], [15], and [16].”
Cai, Q., Xu, X., Suo, Y., Qian, G., Li, Y., Wang, G., Lian, Y., & Zhao, Y. (2024) · Custom Integrated Circuits Conference · doi:10.1109/cicc60959.2024.10529074 · Cited by 4
A Wide-Dynamic-Range, DC-Coupled, Time-Based Neural-Recording IC With Optimized CCO Frequency
Youn, D., Kim, Y.-I., Choi, I., Jung, Y., Jeon, H., Lee, K., Kweon, S.-J., Ha, S., & Je, M. (2024) · IEEE Access · doi:10.1109/access.2024.3424228 · Cited by 3
“2(b)) [1], [2], [3], [4], [5], [6], [7], [8], [9], [10], [11], [12], [13], [14], [15], [16], [17], [18], [19], [20], [21], [22], [23], [24], [25], [26], [27], [28].”
Sayed, G. M., Bartels, A., Dorigo, D. D., Fleiner, T., Roßkothen-Kuhl, N., & Kuhl, M. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3563684 · Cited by 3
Fathy, N. S. K., Vatsyayan, R., Bourhis, A. M., Dayeh, S. A., & Mercier, P. P. (2025) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2025.3560316 · Cited by 3
“In addition, zoom ADCs track the stimulation-artifact signals to avoid over-designing the AFE; however, high DR-AFEs and Zoom-ADC architectures in prior art reported limited bandwidth of 500 Hz (LFP-band) [16], [18], and tend to feature higher power than other approaches due to overdesign.”
A Neural Recording and Stimulation Chip with Artifact Suppression for Biomedical Devices
Liu, X., Li, J., Chen, T., Wang, W., & Je, M. (2021) · Journal of Healthcare Engineering · doi:10.1155/2021/4153155 · Cited by 4
“Reference [49] (REC and STIM) Reference [50] (REC and STIM) Reference [37] (REC and STIM) Reference [40] (REC and STIM) Reference [24] (REC and STIM) +is work (REC and STIM) Process 0.”
BackgroundLee, T., & Je, M. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2305.13463 · Cited by 3
Artifact-Recovery in Neuromodulators using Tunable High-Pass Corners
Reich, S., Fritschi, D., Sporer, M., & Ortmanns, M. (2022) · IEEE Interregional NEWCAS Conference (NEWCAS) · doi:10.1109/newcas52662.2022.9842066 · Cited by 2
Design of CMOS Circuits for Electrophysiology
Helleputte, N. V., López, C. M., & Hoof, C. A. V. (2023) · IEICE Transactions on Electronics · doi:10.1587/transele.2022cti0003 · Cited by 3
“As a result, these architectures have mostly been re-ported in low-bandwidth readouts used for electrocorticography (ECoG) [35], [36], [56], and cannot easily be applied to high-frequency AP recording.”
A ΔΣ Neural Frontend with Stochastic Signal Processing for Stimulation Artifact Suppression
Sayed, G. M., Bartels, A., Dorigo, D. D., & Kuhl, M. (2024) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas61083.2024.10798241 · Cited by 2
Review of AI-on-the-Edge EEG-Based Patient-Specific Epilepsy Tracking SoCs
Zhang, L., Zhang, M., Tsai, C.-W., & Yoo, J. (2022) · IEEE Interregional NEWCAS Conference (NEWCAS) · doi:10.1109/newcas52662.2022.9842203 · Cited by 2
A Bidirectional ASIC for Active Microchannel Neural Interfaces
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2022) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs202256217.2022.9970803 · Cited by 2
Buhmann, A., Lanniel, A., Hiller, T., Sporer, M., Reich, S., & Ortmanns, M. (2025) · Elsevier eBooks · doi:10.1016/b978-0-323-95478-5.00040-6 · Cited by 1
Cai, Q., Xu, X., Suo, Y., Qian, G., Li, Y., Wang, G., Lian, Y., & Zhao, Y. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3567524 · Cited by 1
“These advancements are crucial for neurological electronic implants including retina prosthetics, cochlear implants, deep brain stimulation and vagus nerve stimulation [7], [8], [9], [10], [11], [12].”
InfluentialKim, H., Cho, S., Kim, M. W., Park, C. S., Lee, K., Song, S., Keum, D. S., Lee, S., Jeong, H. E., Jang, D. P., et al. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3642345 · Cited by 1
Wu, H., Tan, Z., Liu, X., Chen, J., Zou, W., Hou, Q., Lin, S., Mao, Y., Kuang, X., Yang, J., et al. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3644885 · Cited by 1
A Continuous-Time Zoom Sensor Readout Frontend With Fast Tracking and Floating-Gm-CCO Integrator
Luo, H., Wang, Z., Wang, J., Li, B., Shen, Z., Liu, Y., Duan, X., Wang, Y., & Tang, X. (2026) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2026.3677053 · Cited by 1
Jeong, K., Livanelioglu, C., Liao, J., Lee, I., & Jang, T. (2026) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2026.3685168 · Cited by 1
“While several discrete-time (DT) DSM structures have been published, their IRN is fundamentally limited by kT / C noise [38], [39], [40].”
VCO-Based ADCs for Direct Digitization of ExG Signals
Pochet, C., & Hall, D. A. (2023) · Springer eBooks · doi:10.1007/978-3-031-28912-5_2 · Cited by 1
2020 Index IEEE Journal of Solid-State Circuits Vol. 55
(2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3054535
Li, L. W., & Sun, J. (2023) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2477/1/012058
“This structure consists of two input differential pairs of M1, M2 and M3, M4, and two resistors with a resistance value of 2R, which are composed of PMOS transistors [5].”
BackgroundWang, W., Zheng, J., Zhou, Y., Su, R., Zhu, L., & Zhou, Z. (2024) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas58744.2024.10558281
“1(c), the signal is quantized by an ADC, and then processed by a digital processor to predict the amplitude of SA through an adaptive filter or other logical algorithms [8][9].”
MethodSimulation of voltage resistance testing for 12-bit low-power ADC chips
Liang, Y. (2025) · Journal of Computational Methods in Sciences and Engineering · doi:10.1177/14727978251361867
Hassan, H., Kamaruddin, N. S., Rahman, A. S. A., Mohamed, M. R., Arof, S., Noorsal, E., Arof, H., & Mawby, P. (2025) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-031-93198-7_7
Noor, N. M., Hassan, H., Arof, S., Ibrahim, N., Noorsal, E., Arof, H., & Mawby, P. (2025) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-031-93198-7_12
Chen, Y., Cao, Y., Li, M., Lin, Q., Huang, K., Tan, Z., Zhao, M., & Song, S. (2025) · doi:10.1109/esserc66193.2025.11214082
Artifact Cancellation in Neurostimulators: A Review
Das, V. R., Karşilayan, A. İ., Silva-Martínez, J., Genzer, D., & Stotts, L. J. (2025) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas53549.2025.11244388
“Analog-to-Digital Converters (ADC) have been reported to aid in artifact resilient front ends, by providing a adaptive dynamic range feature [12], [23], [24].”
Higher-order VCO-based ADCs for Sensor Interfaces
Pochet, C. (2024) · eScholarship (California Digital Library)
Seong, G., Cho, J., Jung, H., Kim, M., Seok, D., Jeon, S. Y., Jang, S., Sung, C., Han, U. G., Park, S., et al. (2026) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2026.3654961
“S IMULTANEOUS neural signal acquisition during electrical stimulation is required for closed-loop control of the neuromodulation [1], [2], [3], [4], [5], as it mitigates overstimulation-induced side effects and optimizes power consumption.”
Liu, Y., Qian, Z., Wei, L., Wang, J., & Shi, C. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3692522
“However, the translation of these neural signatures into actionable data is inherently obstructed by the signal’s fragility—characterized by microvolt-scale amplitudes (10–100 µ V) [2] and a precarious signal-to-noise ratio (SNR) susceptible to environmental coupling [3].”
An Artifact-Suppressing Neural Stimulator Using Differential Push-Pull Architecture
Zhong, M., & Liu, X. (2026) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas66217.2026.11562286
“Multi-polar and multi-site stimulation, for instance, can localize the electric field potential changes due to stimulation [8]-[9] and mitigates recording-site artifacts [10]-[14].”
Liao, H., Yang, X., Chen, M., Li, Y., Qiu, L., Mercier, P. P., & Meng, M. (2026) · IEEE Symposium on VLSI Technology and Circuits (VLSI Technology and Circuits) · doi:10.1109/vlsitechnologyandcir65830.2026.11577626
Metadata
- Authors
- Reza Pazhouhandeh, M., Chang, M., Valiante, T. A., & Genov, R.
- Affiliations
- Department of Electrical and Computer Engineering, University of Toronto, Toronto, ON, Canada
- University of Toronto (CA)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2020-07
- Volume
- 55
- Issue
- 7
- Pages
- 1984-1997
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W3025369647
- Cited by
- 74
- References
- 45
- Citations by year
- 2026: 5 · 2025: 17 · 2024: 11 · 2023: 11 · 2022: 14 · 2021: 13 · 2020: 3
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council (NSERC) of Canada
- Canadian Institutes of Health Research (CIHR).
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- closed-loop neuromodulation, delta modulation, bidirectional neural interface, rodents
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.