Track-and-Zoom Neural Analog-to-Digital Converter With Blind Stimulation Artifact Rejection
The DOI matches its Crossref record; 44 of the 45 references it cites were found in a registry or an index.
Abstract
Closed-loop neuromodulation for the treatment of neurological disorders requires monitoring of the brain activity uninterruptedly even during neurostimulation. This article presents a bidirectional 32-channel CMOS neural interface that can record neural activity during stimulation. Each channel consists of a dc-coupled Δ2Σ-modulated analog-to-digital converter (neural-ADC), which records slow potentials (2Σ-ADC consumes 1.7 μW from 0.6-V/1.2-V digital/analog supplies and time-shares the modulator's feedback DAC as the multi-bit current-mode stimulator operating at 3.3 V. The ADC occupies a silicon area of 0.023 mm2in the 130-nm CMOS and achieves a signal-to-noise-and-distortion ratio (SNDR) of 70 dB over the 500-Hz bandwidth and an equivalent noise efficiency factor (NEF) of 2.86 without a stand-alone front-end amplifier. The 32-channel bidirectionally interfacing prototype is validated in the in vivo whole brain of a rodent.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Track-and-zoom (TAZ) enables automatic detection of artifacts based on the occurrence of amplifier saturation, enabling the rapid adjustment of the input range without the need for synchronisation with the stimulation outputs [189].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [189]
In the citing paper
“There are three categories of artifact suppression techniques in bidirectional interface systems [188], [189].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [189]
In the citing paper
“A track-and-zoom (TAZ) neural ADC is proposed in Reza Pazhouhandeh et al. (2020).”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Reza Pazhouhandeh et al., 2020
In the citing paper
“When fast artifact transients are detected, the multi-bit DAC will feedback to the TAZ ADC.”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Reza Pazhouhandeh et al., 2020
In the citing paper
“As shown in Figure 4F, a recording amplifier and an ADC are combined.”
From Advances in Neural Recording and Stimulation Integrated Circuits (2021) · cites this paper as Reza Pazhouhandeh et al., 2020
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Understanding Delta‐Sigma Data Converters
Schreier, R., Pavan, S., & Temes, G. C. (2017) · Wiley eBooks · doi:10.1002/9781119258308 · Cited by 1,965
Adaptive deep brain stimulation in advanced Parkinson disease.
Little, S., Pogosyan, A., Neal, S., Zavala, B., Zrinzo, L., Hariz, M., Foltynie, T., Limousin, P., Ashkan, K., FitzGerald, J., et al. (2013) · Annals of Neurology · doi:10.1002/ana.23951 · Cited by 1,374
Responsive cortical stimulation for the treatment of medically intractable partial epilepsy
Morrell, M. J. (2011) · Neurology · doi:10.1212/wnl.0b013e3182302056 · Cited by 1,282 · cited 1×
“For example, responsive cortical neurostimulation can abort an epileptic seizure by delivering therapeutic stimulation waveforms after seizure precursors’ detection [4]–[8], and closed-loop deep brain stimulation (DBS) is promising in treating Parkinson’s disease or other motor disorders [9], [10].”
BackgroundClosed-Loop Deep Brain Stimulation Is Superior in Ameliorating Parkinsonism
Rosin, B., Slovik, M., Mitelman, R., Rivlin-Etzion, M., Haber, S. N., Israel, Z., Vaadia, E., & Bergman, H. (2011) · Neuron · doi:10.1016/j.neuron.2011.08.023 · Cited by 793
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Understanding delta-sigma data converters
(2005) · Choice Reviews Online · doi:10.5860/choice.42-4688 · Cited by 791 · cited 1×
“As such, a second-order modulator with two integrators might consume up to 15% more power depending on the scaling factor of the second-stage amplifier if a 10× scaling factor were applied [30].”
BackgroundHeck, C. N., King‐Stephens, D., Massey, A. D., Nair, D. R., Jobst, B. C., Barkley, G. L., Salanova, V., Cole, A. J., Smith, M. C., Gwinn, R. P., et al. (2014) · Epilepsia · doi:10.1111/epi.12534 · Cited by 651 · cited 1×
“NEURAL brain activity contains biomarkers that can be used for the detection and treatment of pathological neurological events by closed-loop neuromodulation [1]–[3].”
BackgroundThe electrical conductivity of human cerebrospinal fluid at body temperature
Baumann, S. B., Wozny, D. R., Kelly, S. K., & Meno, F. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554770 · Cited by 494 · cited 1×
“Given the impedance of cerebrospinal fluid [20] and stimulation electrodes [21], the amplitude of these artifacts can easily exceed the power-supply rail level if a unipolar (single-ended) stimulation method with a high stimulation current is used.”
Denison, T., Consoer, K., Santa, W., Avestruz, A.-T., Cooley, J., & Kelly, A. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2007.908664 · Cited by 451
Sources and effects of electrode impedance during deep brain stimulation
Butson, C. R., Maks, C. B., & McIntyre, C. C. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.10.007 · Cited by 360 · cited 1×
“Given the impedance of cerebrospinal fluid [20] and stimulation electrodes [21], the amplitude of these artifacts can easily exceed the power-supply rail level if a unipolar (single-ended) stimulation method with a high stimulation current is used.”
Stanslaski, S., Afshar, P., Cong, P., Giftakis, J., Stypulkowski, P., Carlson, D., Linde, D., Ullestad, D., Avestruz, A.-T., & Denison, T. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2183617 · Cited by 330 · cited 1×
“Moreover, a high input impedance keeps the dc current low due to the EDO and avoids any tissue damage [31]–[33].”
BackgroundSwann, N. C., de Hemptinne, C., Miocinovic, S., Qasim, S., Wang, S. S., Ziman, N., Ostrem, J. L., San Luciano, M., Galifianakis, N. B., & Starr, P. A. (2016) · The Journal of Neuroscience · doi:10.1523/jneurosci.1128-16.2016 · Cited by 322 · cited 1×
“For example, responsive cortical neurostimulation can abort an epileptic seizure by delivering therapeutic stimulation waveforms after seizure precursors’ detection [4]–[8], and closed-loop deep brain stimulation (DBS) is promising in treating Parkinson’s disease or other motor disorders [9], [10].”
BackgroundResponsive Cortical Stimulation for the Treatment of Epilepsy
Sun, F. T., Morrell, M. J., & Wharen, R. E. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.069 · Cited by 309
Closed-loop Neurostimulation: The Clinical Experience
Sun, F. T., & Morrell, M. J. (2014) · Neurotherapeutics · doi:10.1007/s13311-014-0280-3 · Cited by 286 · cited 1×
“For example, responsive cortical neurostimulation can abort an epileptic seizure by delivering therapeutic stimulation waveforms after seizure precursors’ detection [4]–[8], and closed-loop deep brain stimulation (DBS) is promising in treating Parkinson’s disease or other motor disorders [9], [10].”
BackgroundThe Epileptogenic Zone: Concept and Definition
Jehi, L. (2018) · Epilepsy Currents · doi:10.5698/1535-7597.18.1.12 · Cited by 260 · cited 1×
“Neural stimulation is typically the delivery of controlled biphasic charge-balanced repetitive current pulses into the targeted region of the brain, that is, the ictal onset zone of a patient with epilepsy, to abort the onset of a neurological disorder [37] or to modulate preferred brain activity.”
BackgroundChandrakumar, H., & Markovic, D. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2645611 · Cited by 237 · cited 2×
“To reject stimulation artifact, the stateof-the-art front-ends use high dynamic range amplifiers to accommodate part of the artifact converted into differential mode in a bipolar (differential) stimulation configuration to eliminate any common-mode neural fluctuation during the stimulation [24], [25].”
BackgroundA $160~\mu {\rm W}$ 8-Channel Active Electrode System for EEG Monitoring
Xu, J., Yazicioglu, R. F., Grundlehner, B., Harpe, P., Makinwa, K. A. A., & Van Hoof, C. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2170985 · Cited by 221 · cited 1×
“to suppress the flicker noise without using chopper stabilization, which typically reduces the input impedance of the front-end without an input impedance boosting loop [27].”
BackgroundA Neural Probe With Up to 966 Electrodes and Up to 384 Configurable Channels in 0.13 $\mu$m SOI CMOS
Mora Lopez, C., Putzeys, J., Raducanu, B. C., Ballini, M., Wang, S., Andrei, A., Rochus, V., Vandebriel, R., Severi, S., Van Hoof, C., et al. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2646901 · Cited by 201 · cited 1×
“Different variations in such topology have been reported in [12] and [38].”
BackgroundA 100-channel system for real time detection and storage of extracellular spike waveforms
Guillory, K. S., & Normann, R. A. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00076-x · Cited by 180 · cited 1×
“By assuming that the filtered background noise is 5–10 μVRMS (over the cortical bandwidth) [22] and a common-mode artifact of 1 VPP (regardless of the bandwidth) is not attenuated more than 20 dB by the CMRR of the recording channel, the minimum brute-force signal-to-noise-and-distortion ratio (SNDR) of the recording”
BackgroundSiNAPS: An implantable active pixel sensor CMOS-probe for simultaneous large-scale neural recordings
Angotzi, G. N., Boi, F., Lecomte, A., Miele, E., Malerba, M., Zucca, S., Casile, A., & Berdondini, L. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.032 · Cited by 177 · cited 1×
“Other variations of dc-coupled amplifiers use autozeroing techniques in stand-alone amplifiers before digitization [39] or dynamically adjust the reference potential of the neural-analog-to-digital converter (ADC) (ADC-direct without a stand-alone amplifier) by an external control loop [40] to reject the EDO.”
MethodIntegrated circuit amplifiers for multi-electrode intracortical recording
Jochum, T., Denison, T., & Wolf, P. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/1/012001 · Cited by 167 · cited 1×
“Moreover, a high input impedance keeps the dc current low due to the EDO and avoids any tissue damage [31]–[33].”
BackgroundRail-to-Rail-Input Dual-Radio 64-Channel Closed-Loop Neurostimulator
Kassiri, H., Salam, M. T., Pazhouhandeh, M. R., Soltani, N., Perez Velazquez, J. L., Carlen, P., & Genov, R. (2017) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2749426 · Cited by 160 · cited 8×
“efficient spectrum equalizing techniques [17], [23], which do not require high dynamic range amplifiers, allow hosting of”
BackgroundSelf-citationIndwelling Neural Implants: Strategies for Contending with the In Vivo Environment
(2007) · CRC Press eBooks · doi:10.1201/9781420009309 · Cited by 129 · cited 2×
“would be challenging to design with the power consumption of the neural recording front-end limited to less than 10 μW/channel [41].”
BackgroundJohnson, B. C., Gambini, S., Izyumin, I., Moin, A., Zhou, A., Alexandrov, G., Santacruz, S. R., Rabaey, J. M., Carmena, J. M., & Muller, R. (2017) · 2017 Symposium on VLSI Circuits · doi:10.23919/vlsic.2017.8008543 · Cited by 119 · cited 8×
“3(a) shows a conventional ac-coupled recording AFE architecture.”
BackgroundInfluentialKassiri, H., Bagheri, A., Soltani, N., Abdelhalim, K., Jafari, H. M., Salam, M. T., Perez Velazquez, J. L., & Genov, R. (2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2016.2528999 · Cited by 116 · cited 13×
“The signals at the recording front-end electrodes excluding the common-mode interferers can be categorized as follows: 1) the neural signal; 2) the electrode dc offset (EDO); and 3) the stimulation artifacts as shown in Fig.”
BackgroundSelf-citationBeuter, A., Lefaucheur, J.-P., & Modolo, J. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.01.006 · Cited by 107 · cited 1×
“For example, responsive cortical neurostimulation can abort an epileptic seizure by delivering therapeutic stimulation waveforms after seizure precursors’ detection [4]–[8], and closed-loop deep brain stimulation (DBS) is promising in treating Parkinson’s disease or other motor disorders [9], [10].”
BackgroundKim, C., Joshi, S., Courellis, H., Wang, J., Miller, C., & Cauwenberghs, G. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2870555 · Cited by 104 · cited 3×
“impedance as the input impedance is inversely proportional to the chopping frequency [29] or the IRN of a DT-SC sampling circuit [17].”
BackgroundPark, S.-Y., Cho, J., Na, K., & Yoon, E. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2017.2764053 · Cited by 94
De Dorigo, D., Moranz, C., Graf, H., Marx, M., Wendler, D., Shui, B., Sayed Herbawi, A., Kuhl, M., Ruther, P., Paul, O., et al. (2018) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2018.2873180 · Cited by 93 · cited 1×
“Other variations of dc-coupled amplifiers use autozeroing techniques in stand-alone amplifiers before digitization [39] or dynamically adjust the reference potential of the neural-analog-to-digital converter (ADC) (ADC-direct without a stand-alone amplifier) by an external control loop [40] to reject the EDO.”
Method(2016) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2506651 · Cited by 89 · cited 1×
“Back-end artifactrejection techniques such as post-processing of the signals in the digital domain by adaptive filters are also prone to saturation by large stimulation artifacts [26].”
MethodFuture of Seizure Prediction and Intervention: Closing the Loop
Nagaraj, V., Lee, S. T., Krook-Magnuson, E., Soltesz, I., Benquet, P., Irazoqui, P. P., & Netoff, T. I. (2015) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000139 · Cited by 80 · cited 1×
“, epileptic seizures) during stimulation is necessary to maximize the therapeutic efficacy of the stimulation by adjusting waveform parameters such as shape, amplitude, and frequency [11].”
BackgroundLow-distortion super-GOhm subthreshold-MOS resistors for CMOS neural amplifiers
Kassiri, H., Abdelhalim, K., & Genov, R. (2013) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2013.6679691 · Cited by 70 · cited 1×
“ulation artifact is applied across it [13].”
Self-citationKassiri, H., Pazhouhandeh, R., Soltani, N., Salam, M. T., Carlen, P., Velazquez, J. L. P., & Genov, R. (2017) · 2017 IEEE International Solid-State Circuits Conference (ISSCC) · doi:10.1109/isscc.2017.7870456 · Cited by 51 · cited 1×
“3(c) shows a dc-coupled 2 -modulated neural-ADC previously reported in [16] and [17].”
Self-citationA Sub-${\mu}$W/Ch Analog Front-End for $\Delta $-Neural Recording With Spike-Driven Data Compression
Kim, S.-J., Han, S.-H., Cha, J.-H., Liu, L., Yao, L., Gao, Y., & Je, M. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2880257 · Cited by 49 · cited 1×
“This improvement would also be even higher at higher bandwidths as the neuronal activity spectrum has a 1/ f N (2 < N < 3) spectrum shape where most of the LFPs’ energy spectra reside in a frequency range lower than 500 Hz [19], [23], [34], [35].”
BackgroundA Miniaturized System for Spike-Triggered Intracortical Microstimulation in an Ambulatory Rat
Azin, M., Guggenmos, D. J., Barbay, S., Nudo, R. J., & Mohseni, P. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2159603 · Cited by 46 · cited 1×
“Different variations in such topology have been reported in [12] and [38].”
BackgroundSalam, M. T., Kassiri, H., Genov, R., & Velázquez, J. L. P. (2015) · Epilepsia · doi:10.1111/epi.13064 · Cited by 40 · cited 1×
“This current delivery can be performed in a closed-loop fashion, which, for example, has been recently shown to have high efficacy in aborting epileptic seizures in a rodent epilepsy model [2].”
BackgroundSelf-citationO’Leary, G., Pazhouhandeh, M. R., Chang, M., Groppe, D. M., Valiante, T. A., Verma, N., & Genov, R. (2018) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2018.8310301 · Cited by 33 · cited 3×
“The DAC input coefficients during the stimulation mode are also controlled either by an on-chip (or off-chip) digital back-end processor [28] or wirelessly received data [18].”
BackgroundMethodSelf-citationVelázquez, J. L. P., Dominguez, L. G., Nenadovic, V., & Wennberg, R. A. (2010) · Journal of Biological Physics · doi:10.1007/s10867-010-9205-5 · Cited by 29 · cited 1×
“NEURAL brain activity contains biomarkers that can be used for the detection and treatment of pathological neurological events by closed-loop neuromodulation [1]–[3].”
BackgroundSmith, W. A., Mogen, B. J., Fetz, E. E., Sathe, V., & Otis, B. P. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2518923 · Cited by 23 · cited 2×
“This improvement would also be even higher at higher bandwidths as the neuronal activity spectrum has a 1/ f N (2 < N < 3) spectrum shape where most of the LFPs’ energy spectra reside in a frequency range lower than 500 Hz [19], [23], [34], [35].”
BackgroundArtifact-Tolerant Opamp-Less Delta-Modulated Bidirectional Neuro-Interface
Pazhouhandeh, M. R., Kassiri, H., Shoukry, A., Wesspapir, I., Carlen, P. L., & Genov, R. (2018) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2018.8502286 · Cited by 23 · cited 2×
“The DAC input coefficients during the stimulation mode are also controlled either by an on-chip (or off-chip) digital back-end processor [28] or wirelessly received data [18].”
BackgroundMethodSelf-citationKassiri, H., Pazhouhandeh, M. R., Soltani, N., Salam, M. T., Peter, C., Luiz, P. V. J., & Roman, G. (2017) · IEEE Conference Proceedings · Cited by 18
Generation and On-Demand Initiation of Acute Ictal Activity in Rodent and Human Tissue
Chang, M., Dufour, S., Carlen, P. L., & Valiante, T. A. (2019) · Journal of Visualized Experiments · doi:10.3791/57952 · Cited by 13 · cited 1×
“protocol [36] and performed following the guidelines of the Canadian Council on Animal Care and approved by the Institutional Animal Care Committee.”
MethodSelf-citationA 14-ENOB Delta-Sigma-Based Readout Architecture for ECoG Recording Systems
Ivanisevic, N., Rodriguez, S., & Rusu, A. (2018) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2018.2838135 · Cited by 10 · cited 1×
“This improvement would also be even higher at higher bandwidths as the neuronal activity spectrum has a 1/ f N (2 < N < 3) spectrum shape where most of the LFPs’ energy spectra reside in a frequency range lower than 500 Hz [19], [23], [34], [35].”
BackgroundPazhouhandeh, M. R., Shoaei, O., & Genov, R. (2017) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2017.8050953 · Cited by 2 · cited 1×
“However, this offset cancellation feedback can only remove up to ±50 mV of the EDO [14] and requires a large silicon area or off-chip components [15].”
BackgroundSelf-citation
Cited by
Shaping high-performance wearable robots for human motor and sensory reconstruction and enhancement
Xia, H., Zhang, Y., Rajabi, N., Taleb, F., Yang, Q., Kragić, D., & Li, Z. (2024) · Nature Communications · doi:10.1038/s41467-024-46249-0 · Cited by 163
“Pazhou-handeh et al. proposed a neural ADC that achieves blind stimulation artifact rejection, where a bidirectional COMS neural interface could capture neural signals during neural stimulation 103 .”
BackgroundLee, C., Jeon, T., Jang, M., Park, S., Kim, J., Lim, J., Ahn, J., Huh, Y., & Chae, Y. (2020) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2020.3018478 · Cited by 113
“digitization topologies replacing the conventional combination of IA and ADC have become increasingly popular [11]–[17].”
BackgroundPu, H., Malekzadeh-Arasteh, O., Danesh, A. R., Nenadić, Z., Do, A. H., & Heydari, P. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3108578 · Cited by 79
A Patient-Specific Closed-Loop Epilepsy Management SoC With One-Shot Learning and Online Tuning
Zhang, M., Zhang, L., Tsai, C.-W., & Yoo, J. (2022) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2022.3144460 · Cited by 62
A Bidirectional Neural Interface SoC With Adaptive IIR Stimulation Artifact Cancelers
Samiei, A., & Hashemi, H. (2021) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2021.3056040 · Cited by 49
Metadata
- Authors
- Reza Pazhouhandeh, M., Chang, M., Valiante, T. A., & Genov, R.
- Affiliations
- Department of Electrical and Computer Engineering, University of Toronto, Toronto, ON, Canada
- University of Toronto (CA)
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2020-07
- Volume
- 55
- Issue
- 7
- Pages
- 1984-1997
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W3025369647
- Cited by
- 74
- References
- 45
- Citations by year
- 2026: 5 · 2025: 17 · 2024: 11 · 2023: 11 · 2022: 14 · 2021: 13 · 2020: 3
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Journal of Solid-State Circuits (publishedVersion)
- Funders
- Natural Sciences and Engineering Research Council (NSERC) of Canada
- Canadian Institutes of Health Research (CIHR).
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Keywords
- closed-loop neuromodulation, delta modulation, bidirectional neural interface, rodents
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.