The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
A Fully Fabric-Based Bidirectional Soft Robotic Glove for Assistance and Rehabilitation of Hand Impaired Patients
Abstract
This letter presents a fully fabric-based bidirectional soft robotic glove designed to assist hand impaired patients in rehabilitation exercises and performing activities of daily living. The glove provides both active finger flexion and extension for hand assistance and rehabilitative training, through its embedded fabric-based actuators that are fabricated by heat press and ultrasonic welding of flexible thermoplastic polyurethane-coated fabrics. Compared to previous developed elastomeric-based actuators, the actuators are able to achieve smaller bend radius and generate sufficient force and torque to assist in both finger flexion and extension at lower air pressure. In this letter, experiments were conducted to characterize the performances of the glove in terms of its kinematic and grip strength assistances on five healthy participants. Additionally, we present a graphical-user interface that allows user to choose the desired rehabilitation exercises and control modes, which include button-controlled-assistive mode, cyclic movement training, intention-driven task-specific training, and bilateral rehabilitation training.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design, fabrication and control of soft robots
Rus, D., & Tolley, M. T. (2015) · Nature · doi:10.1038/nature14543 · Cited by 5,825
Soft robotic glove for combined assistance and at-home rehabilitation
Polygerinos, P., Wang, Z., Galloway, K. C., Wood, R. J., & Walsh, C. J. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.014 · Cited by 1,617
Pneumatic Networks for Soft Robotics that Actuate Rapidly
Mosadegh, B., Polygerinos, P., Keplinger, C., Wennstedt, S., Shepherd, R. F., Gupta, U., Shim, J., Bertoldi, K., Walsh, C. J., & Whitesides, G. M. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201303288 · Cited by 1,607
A survey on robotic devices for upper limb rehabilitation
Maciejasz, P., Eschweiler, J., Gerlach-Hahn, K., Jansen-Troy, A., & Leonhardt, S. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-3 · Cited by 1,210
Modeling of Soft Fiber-Reinforced Bending Actuators
Polygerinos, P., Wang, Z., Overvelde, J. T. B., Galloway, K. C., Wood, R. J., Bertoldi, K., & Walsh, C. J. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2428504 · Cited by 910
Snoek, G. J., IJzerman, M. J., Hermens, H. J., Maxwell, D., & Biering-Sorensen, F. (2004) · Spinal Cord · doi:10.1038/sj.sc.3101638 · Cited by 523
Functional range of motion of the joints of the hand
Hume, M. C., Gellman, H., McKellop, H., & Brumfield, R. H. (1990) · The Journal of Hand Surgery · doi:10.1016/0363-5023(90)90102-w · Cited by 338
Pouch Motors: Printable Soft Actuators Integrated with Computational Design
Niiyama, R., Sun, X., Sung, C., An, B., Rus, D., & Kim, S. (2015) · Soft Robotics · doi:10.1089/soro.2014.0023 · Cited by 318
Yap, H. K., Lim, J. H., Nasrallah, F., Goh, J. C. H., & Yeow, R. C. H. (2015) · 2015 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2015.7139889 · Cited by 299
Self-citationConnelly, L., Jia, Y., Toro, M. L., Stoykov, M. E., Kenyon, R. V., & Kamper, D. G. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047588 · Cited by 271
Improving Hand Function in Chronic Stroke
Muellbacher, W., Richards, C., Ziemann, U., Wittenberg, G., Weltz, D., Boroojerdi, B., Cohen, L., & Hallett, M. (2002) · Archives of Neurology · doi:10.1001/archneur.59.8.1278 · Cited by 253
Soft robotic glove for hand rehabilitation and task specific training
Polygerinos, P., Galloway, K. C., Savage, E., Herman, M., Donnell, K. O., & Walsh, C. J. (2015) · 2015 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2015.7139597 · Cited by 239
Cauraugh, J. H., Lodha, N., Naik, S. K., & Summers, J. J. (2010) · Human Movement Science · doi:10.1016/j.humov.2009.09.004 · Cited by 170
Development of a polymer-based tendon-driven wearable robotic hand
Kang, B. B., Lee, H., In, H., Jeong, U., Chung, J., & Cho, K.-J. (2016) · 2016 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2016.7487562 · Cited by 164
Mirror therapy for improving motor function after stroke
Thieme, H., Mehrholz, J., Pohl, M., Behrens, J., & Dohle, C. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008449.pub2 · Cited by 147
An Actuated Finger Exoskeleton for Hand Rehabilitation Following Stroke
Worsnopp, T., Peshkin, M. A., Colgate, J. E., & Kamper, D. G. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428530 · Cited by 146
Lee, S. W., Landers, K. A., & Park, H. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2298362 · Cited by 128
Yap, H. K., Ang, B. W. K., Lim, J. H., Goh, J., & Yeow, C. (2016) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2016.7487535 · Cited by 122
Self-citationWearable power assist device for hand grasping using pneumatic artificial rubber muscle
SASAKI, D., Noritsugu, T., TAKAIWA, M., et al. (2005) · IEEE RO-MAN · doi:10.1109/roman.2004.1374840 · Cited by 105
Yap, H. K., Kamaldin, N., Lim, J. H., Nasrallah, F. A., Goh, J. C., & Yeow, C. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2602941 · Cited by 105
Self-citationBenchmarking grasping and manipulation: Properties of the Objects of Daily Living
Matheus, K., & Dollar, A. M. (2010) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2010.5649517 · Cited by 100
Fischer, H. C., Triandafilou, K. M., Thielbar, K. O., Ochoa, J. M., Lazzaro, E., Pacholski, K. A., & Kamper, D. G. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2513675 · Cited by 100
Orthotic aided training of the paretic upper limb in chronic stroke: Results of a phase 1 trial
Farrell, J. F., Hoffman, H. B., Snyder, J. L., Giuliani, C., & Bohannon, R. W. (2007) · Neurorehabilitation · doi:10.3233/nre-2007-22204 · Cited by 61
Cited by
Robotic Artificial Muscles: Current Progress and Future Perspectives
Zhang, J., Sheng, J., O'Neill, C. T., Walsh, C. J., Wood, R. J., Ryu, J.-H., Desai, J. P., & Yip, M. C. (2019) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2894371 · Cited by 398
Textile Technology for Soft Robotic and Autonomous Garments
Sanchez, V., Walsh, C. J., & Wood, R. J. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008278 · Cited by 292
Sun, Z., Zhu, M., Zhang, Z., Chen, Z., Shi, Q., Shan, X., Yeow, R. C. H., & Lee, C. (2021) · Advanced Science · doi:10.1002/advs.202100230 · Cited by 270
Kang, B. B., Choi, H., Lee, H., & Cho, K.-J. (2019) · Soft Robotics · doi:10.1089/soro.2018.0006 · Cited by 257
Metadata
- Authors
- Yap, H. K., Khin, P. M., Koh, T. H., Sun, Y., Liang, X., Lim, J. H., & Yeow, C.-H.
- Venue
- IEEE Robotics and Automation Letters
- Published
- 2017-07
- Volume
- 2
- Issue
- 3
- Pages
- 1383-1390
- ISSN
- 2377-3766 (ISSN-L)
- 2377-3774
- OpenAlex
- W2588682554
- Cited by
- 277
- References
- 23
- FWCI
- 8.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.