We report a portable respiration sensor for the analysis of respiration rates, patterns, and phases during exercise. A silica nanoparticle thin film on a flexible substrate is used as a sensor chip (4.1 mm × 5 mm in area of electrodes) to detect respiration. Response and recovery time of the sensor chip are 0.7 and 1.7 s to detect human respiration. Even when it is covered with water, the response quickly recovers within 1 s after removal of the water. A portable respiration sensor can track respiration rates up to 1.7 Hz at rest. The sensor also monitors respiration patterns and phases during exercise noninvasively. The fast-response and portable respiration sensor is usable as a healthcare device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/lsens.2017.2787099

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 47

Metadata

Authors
Kano, S., Dobashi, Y., & Fujii, M.
Venue
IEEE Sensors Letters
Published
2018-03
Volume
2
Issue
1
Pages
1-4
ISSN
2475-1472 (ISSN-L)
OpenAlex
W2777657577
Cited by
47
References
2
FWCI
2.33
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.