Silica Nanoparticle-Based Portable Respiration Sensor for Analysis of Respiration Rate, Pattern, and Phase During Exercise
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We report a portable respiration sensor for the analysis of respiration rates, patterns, and phases during exercise. A silica nanoparticle thin film on a flexible substrate is used as a sensor chip (4.1 mm × 5 mm in area of electrodes) to detect respiration. Response and recovery time of the sensor chip are 0.7 and 1.7 s to detect human respiration. Even when it is covered with water, the response quickly recovers within 1 s after removal of the water. A portable respiration sensor can track respiration rates up to 1.7 Hz at rest. The sensor also monitors respiration patterns and phases during exercise noninvasively. The fast-response and portable respiration sensor is usable as a healthcare device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408 · cited 2×
“Several new types of respiration sensors have been developed for accurate electrical measurements of respiration [1], [10].”
BackgroundPaper‐Based Electrical Respiration Sensor
Güder, F., Ainla, A., Redston, J., Mosadegh, B., Glavan, A., Martin, T. J., & Whitesides, G. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201511805 · Cited by 472 · cited 2×
“ration sensor has been demonstrated for measuring a respiration rate during walking [9].”
BackgroundMethod
Cited by
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Wu, J., Wu, Z., Xu, H., Wu, Q., Liu, C., Yang, B.-R., Gui, X., Xie, X., Tao, K., Shen, Y., et al. (2019) · Materials Horizons · doi:10.1039/c8mh01160e · Cited by 391
Wearable humidity sensor based on porous graphene network for respiration monitoring
Pang, Y., Jian, J., Tu, T., Yang, Z., Ling, J., Li, Y., Wang, X., Qiao, Y., Tian, H., Yang, Y., et al. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.038 · Cited by 369
Recent development of respiratory rate measurement technologies
Liu, H., Allen, J., Zheng, D., & Chen, F. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab299e · Cited by 266
Human Vital Signs Detection Methods and Potential Using Radars: A Review
Kebe, M., Gadhafi, R., Mohammad, B., Sanduleanu, M., Saleh, H., & Al-Qutayri, M. (2020) · Sensors · doi:10.3390/s20051454 · Cited by 205
“As we will see in the next section, vital signs measurement using chest displacement sensing can be non-invasive while providing good accuracy.”
Humidity Sensing of Stretchable and Transparent Hydrogel Films for Wireless Respiration Monitoring
Liang, Y., Ding, Q., Wang, H., Wu, Z., Li, J., Li, Z., Tao, K., Gui, X., & Wu, J. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00934-1 · Cited by 162
Gao, Y., Jia, F., & Gao, G. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.132919 · Cited by 95
Metadata
- Authors
- Kano, S., Dobashi, Y., & Fujii, M.
- Venue
- IEEE Sensors Letters
- Published
- 2018-03
- Volume
- 2
- Issue
- 1
- Pages
- 1-4
- ISSN
- 2475-1472 (ISSN-L)
- OpenAlex
- W2777657577
- Cited by
- 47
- References
- 2
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.