Wireless smart implants dedicated to multichannel monitoring and microstimulation
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Innovative circuits and systems techniques are required to build advanced smart medical devices (SMD). The high reliability and very low power consumption are among the main criteria that must be given priority to implement in such implantable and wirelessly controlled microsystems. A typical device is composed of several integrated modules to be assembled on a thin substrate providing placement flexibility in the body. Monitoring of electrode-tissue interface condition is needed for enhanced safety, and for enabling troubleshooting after implantation. In order to improve controllability and observability, fully integrated binary phase-shift-keying (BPSK) demodulation combined with a passive modulation method allows full-duplex data high data rate communication between external controllers and implants. Case studies such as peripheral nerve interfaces to recuperate bladder functions, cortical multichannel stimulator, as well as cortical monitoring devices are reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Smith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270
Neuroprosthetics: Theory and Practice
Horch, K. W., & Dhillon, G. S. (2004) · Series on Bioengineering and Biomedical Engineering · doi:10.1142/4987 · Cited by 70
Cited by
High-Speed OQPSK and Efficient Power Transfer Through Inductive Link for Biomedical Implants
Simard, G., Sawan, M., & Massicotte, D. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2039212 · Cited by 193
“Polystim Neurotechnologies Laboratory’s work has produced a high-speed bidirectional transceiver using the offset quadrature phase-shift keying (OQPSK) modulation scheme that can be used for bidirectional transmission of information [4], [5].”
MethodSelf-citationRecent Advances in Neural Recording Microsystems
Gosselin, B. (2011) · Sensors · doi:10.3390/s110504572 · Cited by 138
Cortical visual prostheses: From microstimulation to functional percept
Najarpour Foroushani, A., Pack, C. C., & Sawan, M. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaa904 · Cited by 62
Self-citation
Metadata
- Authors
- Sawan, M., Hu, Y., & Coulombe, J.
- Venue
- IEEE Circuits and Systems Magazine
- Published
- 2005
- Volume
- 5
- Issue
- 1
- Pages
- 21-39
- ISSN
- 0163-6812 (ISSN-L)
- 1531-636X
- OpenAlex
- W2155465285
- Cited by
- 201
- References
- 3
- FWCI
- 13.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wireless smart implants dedicated to multichannel monitoring and microstimulation. https://app.cochat.ai/papers/10.1109/mcas.2005.1405898
- The paper
- Sawan, M., Hu, Y., & Coulombe, J. (2005). Wireless smart implants dedicated to multichannel monitoring and microstimulation. IEEE Circuits and Systems Magazine. https://doi.org/10.1109/mcas.2005.1405898
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.