Quantitative evaluation of movement using the timed up-and-go test
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this study, the combined use of an accelerometer and rate gyrosensor to identify the activity phases of the timed up-and-go test (TUG-T) was proposed. Measurements during clinical rehabilitation of hemiplegic patients have been attempted using a triaxial accelerometer to measure the activity objectively, which allows a quantitative evaluation. A waist gyrosensor is useful for measuring the postural displacement with high accuracy. By using both the accelerometer and gyrosensor signals, it was possible to detect the activity phases, which were similar to those observed by the therapists. In addition, the walking activity was extracted from the TUG-T, and the RMS value and CV from the acceleration were calculated in every walking cycle. A qualitative difference between the subjects who could walk independently and those requiring supervision was revealed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Risk factors and risk assessment tools for falls in hospital in-patients: a systematic review
Oliver, D. (2004) · Age and Ageing · doi:10.1093/ageing/afh017 · Cited by 714 · cited 1×
“The total time taken to complete the TUG-T is used to predict the risk of falling [1]–[4].”
MethodMeasuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Cited by
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
“The time taken to perform each activity state can be objectively identified and the movement characteristics can be analyzed as well [85].”
BackgroundiTUG, a Sensitive and Reliable Measure of Mobility
Salarian, A., Horak, F. B., Zampieri, C., Carlson-Kuhta, P., Nutt, J. G., & Aminian, K. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2047606 · Cited by 489
“[15] defined onset and offset of turns by finding the time trunk angular velocity crossed a fixed threshold level.”
InfluentialZampieri, C., Salarian, A., Carlson-Kuhta, P., Aminian, K., Nutt, J. G., & Horak, F. B. (2010) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2009.173740 · Cited by 366
Quantitative Falls Risk Assessment Using the Timed Up and Go Test
Greene, B. R., O'Donovan, A., Romero-Ortuno, R., Cogan, L., Scanaill, C. N., & Kenny, R. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2083659 · Cited by 261
Adame, M. R., Al-Jawad, A., Romanovas, M., Hobert, M. A., Maetzler, W., Möller, K., & Manoli, Y. (2012) · Biomedical Engineering / Biomedizinische Technik · doi:10.1515/bmt-2012-4426 · Cited by 24
Wearable Inertial Sensors and Their Applications
Tamura, T. (2014) · Wearable Sensors · doi:10.1016/b978-0-12-418662-0.00024-6 · Cited by 19
Self-citation
Metadata
- Authors
- Higashi, Y., Yamakoshi, K., Fujimoto, T., Sekine, M., & Tamura, T.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2008-07
- Volume
- 27
- Issue
- 4
- Pages
- 38-46
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2108749649
- Cited by
- 99
- References
- 2
- FWCI
- 5.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.