The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Wearable Electroencephalography
Abstract
The electroencephalogram (EEG) is a classic noninvasive method for measuring a person's brain waves and is used in a large number of fields: from epilepsy and sleep disorder diagnosis to brain-computer interfaces (BCIs). Electrodes are placed on the scalp to detect the microvolt-sized signals that result from synchronized neuronal activity within the brain. Current long-term EEG monitoring is generally either carried out as an inpatient in combination with video recording and long cables to an amplifier and recording unit or is ambulatory. In the latter, the EEG recorder is portable but bulky, and in principle, the subject can go about their normal daily life during the recording. In practice, however, this is rarely the case. It is quite common for people undergoing ambulatory EEG monitoring to take time off work and stay at home rather than be seen in public with such a device. Wearable EEG is envisioned as the evolution of ambulatory EEG units from the bulky, limited lifetime devices available today to small devices present only on the head that can record EEG for days, weeks, or months at a time. Such miniaturized units could enable prolonged monitoring of chronic conditions such as epilepsy and greatly improve the end-user acceptance of BCI systems. In this article, we aim to provide a review and overview of wearable EEG technology, answering the questions: What is it, why is it needed, and what does it entail? We first investigate the requirements of portable EEG systems and then link these to the core applications of wearable EEG technology: epilepsy diagnosis, sleep disorder diagnosis, and BCIs. As a part of our review, we asked 21 neurologists (as a key user group) for their views on wearable EEG. This group highlighted that wearable EEG will be an essential future tool. Our descriptions here will focus mainly on epilepsy and the medical applications of wearable EEG, as this is the historical background of the EEG, our area of expertise, and a core motivating area in itself, but we will also discuss the other application areas. We continue by considering the forthcoming research challenges, principally new electrode technology and lower power electronics, and we outline our approach for dealing with the electronic power issues. We believe that the optimal approach to realizing wearable EEG technology is not to optimize any one part but to find the best set of tradeoffs at both the system and implementation level. In this article, we discuss two of these tradeoffs in detail: investigating the online compression of EEG data to reduce the system power consumption and the optimal method for providing this data compression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
EEG in the diagnosis, classification, and management of patients with epilepsy
Smith, S. J. M. (2005) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2005.069245 · Cited by 798
Self-citationAccess to Diagnosis and Treatment of Patients with Suspected Sleep Apnea
Flemons, W. W., Douglas, N. J., Kuna, S. T., Rodenstein, D. O., & Wheatley, J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200308-1124pp · Cited by 670
The misdiagnosis of epilepsy and the management of refractory epilepsy in a specialist clinic
Smith, D. (1999) · QJM · doi:10.1093/qjmed/92.1.15 · Cited by 446
Power Sources for Wireless Sensor Networks
Roundy, S., Steingart, D., Frechette, L., Wright, P., & Rabaey, J. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24606-0_1 · Cited by 297
Spike detection: a review and comparison of algorithms
Wilson, S. B., & Emerson, R. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00297-3 · Cited by 294
A 200 μW Eight-Channel EEG Acquisition ASIC for Ambulatory EEG Systems
Yazicioglu, R. F., Merken, P., Puers, R., & Van Hoof, C. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2006462 · Cited by 271
Energy-efficient DSPs for wireless sensor networks
Wang, A., & Chandrakasan, A. (2002) · IEEE Signal Processing Magazine · doi:10.1109/msp.2002.1012351 · Cited by 243
Automatic Detection of Seizures and Spikes
Gotman, J. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199903000-00005 · Cited by 232
Optimization of inertial micropower Generators for human walking motion
von Buren, T., Mitcheson, P. D., Green, T. C., Yeatman, E. M., Holmes, A. S., & Troster, G. (2006) · IEEE Sensors Journal · doi:10.1109/jsen.2005.853595 · Cited by 215
A 0.5-v 1--μW successive approximation adc
Sauerbrey, J., Schmitt-Landsiedel, D., & Thewes, R. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.813217 · Cited by 208
Estimating the Cost of Epilepsy in Europe: A Review with Economic Modeling
Pugliatti, M., Beghi, E., Forsgren, L., Ekman, M., & Sobocki, P. (2007) · Epilepsia · doi:10.1111/j.1528-1167.2007.01251.x · Cited by 197
A dry electrode for EEG recording
Taheri, B. A., Knight, R. T., & Smith, R. L. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90053-1 · Cited by 176
Human++: autonomous wireless sensors for body area networks
Gyselinckx, B., Van Hoof, C., Ryckaert, J., Yazicioglu, R. F., Fiorini, P., & Leonov, V. (2006) · Proceedings of the IEEE 2005 Custom Integrated Circuits Conference, 2005. · doi:10.1109/cicc.2005.1568597 · Cited by 162
Noninvasive Neural Prostheses Using Mobile and Wireless EEG
Lin, C.-T., Ko, L.-W., Chiou, J.-C., Duann, J.-R., Huang, R.-S., Liang, S.-F., Chiu, T.-W., & Jung, T.-P. (2008) · Proceedings of the IEEE · doi:10.1109/jproc.2008.922561 · Cited by 160
A Novel Dry Active Electrode for EEG Recording
Fonseca, C., Cunha, J. P. S., Martins, R. E., Ferreira, V. M., de, J. P. M., Barbosa, M. A., & da Silva, A. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.884649 · Cited by 151
Automatic recognition of inter-ictal epileptic activity in prolonged EEG recordings
Gotman, J., Ives, J. R., & GLOOR, P. (1979) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(79)90004-x · Cited by 147
Modern electroencephalography: its role in epilepsy management
Binnie, C. D., & Stefan, H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00125-x · Cited by 138
New horizons in ambulatory electroencephalography
Waterhouse, E. J. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213629 · Cited by 129
First human trials of a dry electrophysiology sensor using a carbon nanotube array interface
Ruffini, G., Dunne, S., Fuentemilla, L., Grau, C., Farrés, E., Marco‐Pallarés, J., Watts, P. C. P., & Silva, S. R. P. (2008) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2008.03.007 · Cited by 113
A 1 V Wireless Transceiver for an Ultra-Low-Power SoC for Biotelemetry Applications
Wong, A. C. W., Kathiresan, G., Chan, C. K. T., Eljamaly, O., Omeni, O., McDonagh, D., Burdett, A. J., & Toumazou, C. (2008) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.923717 · Cited by 100
A wavelet-packets based algorithm for EEG signal compression
Cardenas-Barrera, J. L., Lorenzo‐Ginori, J. V., & Rodríguez-Valdivia, E. (2004) · Medical Informatics and the Internet in Medicine · doi:10.1080/14639230310001636499 · Cited by 91
Wearable EEG: what is it, why is it needed and what does it entail?
Casson, A. J., Smith, S. J. M., Duncan, J. S., & Rodriguez–Villegas, E. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650549 · Cited by 88
Self-citationNew Chronic EEG Electrode for Critical/Intensive Care Unit Monitoring
Ives, J. R. (2005) · Journal of Clinical Neurophysiology · doi:10.1097/01.wnp.0000152659.30753.47 · Cited by 70
Dense array EEG: Methodology and new hypothesis on epilepsy syndromes
Holmes, M. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2008.01505.x · Cited by 68
Toward Online Data Reduction for Portable Electroencephalography Systems in Epilepsy
Casson, A. J., & Rodriguez–Villegas, E. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2027607 · Cited by 53
Self-citationWearable Autonomous Wireless Electro-encephalography System Fully Powered by Human Body Heat
Torfs, T., Leonov, V. N., Yazıcıoğlu, R. F., Merken, P. J., Hoof, C. A. V., Vullers, R. J. M., & Gyselinckx, B. (2008) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2008.4716675 · Cited by 47
A Key Power Trade-off in Wireless EEG Headset Design
Yates, D. C., & Rodriguez–Villegas, E. (2007) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2007.369707 · Cited by 40
Self-citationAn Adaptive Sampling System for Sensor Nodes in Body Area Networks
Rieger, R., & Taylor, J. T. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008648 · Cited by 39
Performance metrics for the accurate characterisation of interictal spike detection algorithms
Casson, A. J., Luna, E., & Rodriguez–Villegas, E. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.10.010 · Cited by 37
Self-citationMartz, G. U., Hucek, C., & Quigg, M. (2009) · Neurocritical Care · doi:10.1007/s12028-009-9215-y · Cited by 15
An Ultra Low Power Low Noise Chopper Amplifier for Wireless BEG
Yates, D. C., & Rodriguez–Villegas, E. (2006) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2006.382309 · Cited by 14
Self-citation
Cited by
Parlak, O., Keene, S. T., Marais, A., Curto, V. F., & Salleo, A. (2018) · Science Advances · doi:10.1126/sciadv.aar2904 · Cited by 603
A review on transfer learning in EEG signal analysis
Wan, Z., Yang, R., Huang, M., Zeng, N., & Liu, X. (2021) · Neurocomputing · doi:10.1016/j.neucom.2020.09.017 · Cited by 468
Lower Limb Wearable Robots for Assistance and Rehabilitation: A State of the Art
Huo, W., Mohammed, S., Moreno, J. C., & Amirat, Y. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2351491 · Cited by 455
Unobtrusive ambulatory EEG using a smartphone and flexible printed electrodes around the ear
Debener, S., Emkes, R., De Vos, M., & Bleichner, M. (2015) · Scientific Reports · doi:10.1038/srep16743 · Cited by 382
Casson, A. J. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-018-00093-6 · Cited by 340
Self-citation
Metadata
- Authors
- Casson, A., Yates, D., Smith, S., Duncan, J., & Rodriguez-Villegas, E.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2010-05
- Volume
- 29
- Issue
- 3
- Pages
- 44-56
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W29918989
- Cited by
- 404
- References
- 33
- FWCI
- 12.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.