The increasing proliferation of renewable energy resources and new sizeable loads like electric vehicle (EV) charging stations has posed many technical and operational challenges to distribution grids [1]. Encouraged by attractive tax incentives and promotion policies, local grid end consumers are becoming not only consumers of electricity but, in many cases, also producers. The actual electric distribution system limits the use of renewable energy resources, offers poor EV infrastructure, and is based on a unidirectional information flow from sources to control centers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Hereafter, the NPC which is the three-level approach is the most recommended one which enables the use of 600-V power devices and eventually increases the efficiency of the system [22].”
From State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements (2020) · cites this paper as [22]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The advantages of modular concept over the first solution are the low electromagnetic interference emission and the realization of using LV-rating power devices, which increase the fault tolerance in this stage [22].”
From State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements (2020) · cites this paper as [22]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smart Grid Technologies: Communication Technologies and Standards
Gungor, V. C., Sahin, D., Kocak, T., Ergut, S., Buccella, C., Cecati, C., & Hancke, G. P. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2011.2166794 · Cited by 2,688
Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives
Rodriguez, J., Bernet, S., Wu, B., Pontt, J. O., & Kouro, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907044 · Cited by 2,385
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Liserre, M., Sauter, T., & Hung, J. (2010) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2010.935861 · Cited by 1,054
Self-citationA Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Toward Reliable Power Electronics: Challenges, Design Tools, and Opportunities
Wang, H., Liserre, M., & Blaabjerg, F. (2013) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2252958 · Cited by 916
Self-citationSurvey on Fault-Tolerant Techniques for Power Electronic Converters
Zhang, W., Xu, D., Enjeti, P. N., Li, H., Hawke, J. T., & Krishnamoorthy, H. S. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2304561 · Cited by 587
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478
Integration Issues of Distributed Generation in Distribution Grids
Coster, E. J., Myrzik, J. M. A., Kruimer, B., & Kling, W. L. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2052776 · Cited by 422
Silicon Carbide Power Transistors: A New Era in Power Electronics Is Initiated
Rabkowski, J., Peftitsis, D., & Nee, H. (2012) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2012.2193291 · Cited by 422
Research works printed but not linked: 3
- McMurray, E. "Power Converter Circuits Having a High Frequency Link", Patent: US3517300, 1968.
- Brooks, J.L. "Solid State Regulated Power Transformer with Waveform Conditioning Capability", Patent US4347474 A, 1980.
- ERC Consolidator Grant Project HEART "The Highly Efficient And Reliable smart Transformer", 2014-2018, http://www.heart.tf.uni-kiel.de/.
Cited by
Kim, H., Choi, H., Kang, H., An, J., Yeom, S., & Hong, T. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.110755 · Cited by 367
Junction Temperature Control for More Reliable Power Electronics
Andresen, M., Ma, K., Buticchi, G., Falck, J., Blaabjerg, F., & Liserre, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2665697 · Cited by 345
“this application, due to the presence of the dc links, that allow an independent reactive power control in the medium-voltage and low-voltage (LV) side [29].”
BackgroundMethodInfluentialSelf-citationHannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“In contrast to CHB, MMC has a complex control system, however, it provides the DC link for the connection ofMVDC loads sources.”
BackgroundMethodInfluentialFerreira Costa, L., De Carne, G., Buticchi, G., & Liserre, M. (2017) · IEEE Power Electronics Magazine · doi:10.1109/mpel.2017.2692381 · Cited by 303
Self-citationSolar Photovoltaic and Thermal Energy Systems: Current Technology and Future Trends
Malinowski, M., Leon, J. I., & Abu-Rub, H. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2690343 · Cited by 213
Metadata
- Authors
- Liserre, M., Buticchi, G., Andresen, M., De Carne, G., Costa, L. F., & Zou, Z.-X.
- Affiliations
- Christian-Albrechts-Universität zu Kiel (DE)
- Venue
- IEEE Industrial Electronics Magazine
- Published
- 2016-06
- Volume
- 10
- Issue
- 2
- Pages
- 46-58
- ISSN
- 1932-4529 (ISSN-L)
- OpenAlex
- W2442002586
- Cited by
- 445
- References
- 34
- Citations by year
- 2026: 15 · 2025: 40 · 2024: 45 · 2023: 40 · 2022: 39 · 2021: 60 · 2020: 52 · 2019: 51 · 2018: 48 · 2017: 41 · 2016: 14
- FWCI
- 23.68
- Type
- journal article
- Language
- en
- Open access
- green
- macau.uni-kiel.de
- Locations
- IEEE Industrial Electronics Magazine (publishedVersion)
- Multimedialen Archiv und Publikationsserver der Christian-Albrechts-Universität zu Kiel (Christian-Albrechts-Universität zu Kiel) (submittedVersion)
- Multimedialen Archiv und Publikationsserver der Christian-Albrechts-Universität zu Kiel (Christian-Albrechts-Universität zu Kiel) (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid and Power Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- solid-state transformer, electric distribution grid, renewable energy integration, electric vehicle charging stations, distributed generation, bidirectional information flow, electric vehicle charging infrastructure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.