The Smart Transformer: Impact on the Electric Grid and Technology Challenges
Open accessThe DOI matches its Crossref record; 31 of the 34 references it cites were found in a registry or an index.
Abstract
The increasing proliferation of renewable energy resources and new sizeable loads like electric vehicle (EV) charging stations has posed many technical and operational challenges to distribution grids [1]. Encouraged by attractive tax incentives and promotion policies, local grid end consumers are becoming not only consumers of electricity but, in many cases, also producers. The actual electric distribution system limits the use of renewable energy resources, offers poor EV infrastructure, and is based on a unidirectional information flow from sources to control centers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Hereafter, the NPC which is the three-level approach is the most recommended one which enables the use of 600-V power devices and eventually increases the efficiency of the system [22].”
From State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements (2020) · cites this paper as [22]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The advantages of modular concept over the first solution are the low electromagnetic interference emission and the realization of using LV-rating power devices, which increase the fault tolerance in this stage [22].”
From State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements (2020) · cites this paper as [22]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smart Grid Technologies: Communication Technologies and Standards
Gungor, V. C., Sahin, D., Kocak, T., Ergut, S., Buccella, C., Cecati, C., & Hancke, G. P. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2011.2166794 · Cited by 2,688
Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives
Rodriguez, J., Bernet, S., Wu, B., Pontt, J. O., & Kouro, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907044 · Cited by 2,385
Review of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Liserre, M., Sauter, T., & Hung, J. (2010) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2010.935861 · Cited by 1,054
Self-citationA Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Toward Reliable Power Electronics: Challenges, Design Tools, and Opportunities
Wang, H., Liserre, M., & Blaabjerg, F. (2013) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2252958 · Cited by 916
Self-citationSurvey on Fault-Tolerant Techniques for Power Electronic Converters
Zhang, W., Xu, D., Enjeti, P. N., Li, H., Hawke, J. T., & Krishnamoorthy, H. S. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2304561 · Cited by 587
Power Electronic Traction Transformer—Medium Voltage Prototype
Zhao, C., Dujic, D., Mester, A., Steinke, J. K., Weiss, M., Lewdeni-Schmid, S., Chaudhuri, T., & Stefanutti, P. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2278960 · Cited by 478
Integration Issues of Distributed Generation in Distribution Grids
Coster, E. J., Myrzik, J. M. A., Kruimer, B., & Kling, W. L. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2010.2052776 · Cited by 422
Silicon Carbide Power Transistors: A New Era in Power Electronics Is Initiated
Rabkowski, J., Peftitsis, D., & Nee, H. (2012) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2012.2193291 · Cited by 422
Research works printed but not linked: 3
- McMurray, E. "Power Converter Circuits Having a High Frequency Link", Patent: US3517300, 1968.
- Brooks, J.L. "Solid State Regulated Power Transformer with Waveform Conditioning Capability", Patent US4347474 A, 1980.
- ERC Consolidator Grant Project HEART "The Highly Efficient And Reliable smart Transformer", 2014-2018, http://www.heart.tf.uni-kiel.de/.
Cited by
Kim, H., Choi, H., Kang, H., An, J., Yeom, S., & Hong, T. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.110755 · Cited by 367
Junction Temperature Control for More Reliable Power Electronics
Andresen, M., Ma, K., Buticchi, G., Falck, J., Blaabjerg, F., & Liserre, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2665697 · Cited by 345
“this application, due to the presence of the dc links, that allow an independent reactive power control in the medium-voltage and low-voltage (LV) side [29].”
BackgroundMethodInfluentialSelf-citationHannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“In contrast to CHB, MMC has a complex control system, however, it provides the DC link for the connection ofMVDC loads sources.”
BackgroundMethodInfluentialFerreira Costa, L., De Carne, G., Buticchi, G., & Liserre, M. (2017) · IEEE Power Electronics Magazine · doi:10.1109/mpel.2017.2692381 · Cited by 303
Self-citationSolar Photovoltaic and Thermal Energy Systems: Current Technology and Future Trends
Malinowski, M., Leon, J. I., & Abu-Rub, H. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2690343 · Cited by 213
High-Efficiency SiC-Based Isolated Three-Port DC/DC Converters for Hybrid Charging Stations
Dao, N. D., Lee, D.-C., & Phan, Q. D. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2975124 · Cited by 174
“As a result, the capacitance and, thus, the volume of the dc-link capacitor can be reduced [28].”
BackgroundAizpurua, J. I., McArthur, S. D. J., Stewart, B. G., Lambert, B., Cross, J. G., & Catterson, V. M. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2860532 · Cited by 170
“transformers are crucial because their failure can lead to lack of export capability or even to catastrophic failures [1], [2].”
BackgroundVarajao, D., Araujo, R. E., Miranda, L. M., & Lopes, J. A. P. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2752123 · Cited by 167
“Bidirectional ac–dc converters are required for several applications, such as battery energy storage systems [2], chargers for electric vehicles [5], uninterruptible power supplies [6], solidstate transformers [7], and dc microgrids [8].”
BackgroundAhmad, A., Qin, Z., Wijekoon, T., & Bauer, P. (2022) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2022.3179743 · Cited by 160
“[115], the authors discuss the structural modularity, control strategies, possible”
BackgroundCarne, G. D., Maroufi, S. M., Beiranvand, H., Angelis, V. D., D’Arco, S., Gevorgian, V., Waczowicz, S., Mather, B. A., Liserre, M., & Hagenmeyer, V. (2024) · Electric Power Systems Research · doi:10.1016/j.epsr.2024.110963 · Cited by 184
Self-citationCosta, L. F., & Liserre, M. (2018) · IEEE Power Electronics Magazine · doi:10.1109/mpel.2018.2874345 · Cited by 142
“44 IEEE PowEr ElEctronIcs MagazInE z December 2018 [1]–[9] have been discussed.”
BackgroundSelf-citationRuiz, F., Pérez, M. A., Espinosa, J. R., Gajowik, T., Styński, S., & Malinowski, M. (2020) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2019.2950436 · Cited by 143
“(k) Multiwinding mid-frequency smart transformer [29].”
BackgroundInfluentialD’silva, S., Shadmand, M. B., Bayhan, S., & Abu‐Rub, H. (2020) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2020.2988618 · Cited by 140
“former has been incorporated in MGs to regulate the power demand-response balance in GC mode [63], [64].”
MethodQuad-Active-Bridge DC–DC Converter as Cross-Link for Medium-Voltage Modular Inverters
Costa, L. F., Buticchi, G., & Liserre, M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2633539 · Cited by 118
Self-citationPower system resilience and strategies for a sustainable infrastructure: A review
Mohanty, A., Ramasamy, A. K., Verayiah, R., Bastia, S., Dash, S. S., Cüce, E., Khan, T. M. Y., & Soudagar, M. E. M. (2024) · Alexandria Engineering Journal · doi:10.1016/j.aej.2024.06.092 · Cited by 154
A review on solid-state transformer: A breakthrough technology for future smart distribution grids
Mishra, D. K., Ghadi, M. J., Li, L., Hossain, M. J., Zhang, J., Ray, P. K., & Mohanty, A. (2021) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107255 · Cited by 129
Soft Open Point in Distribution Networks
Fuad, K. S., Hafezi, H., Kauhaniemi, K., & Laaksonen, H. J. J. (2020) · IEEE Access · doi:10.1109/access.2020.3039552 · Cited by 129
“The modular architecture of the ST has better aspects than non-modular and semimodular architecture [22], [23].”
BackgroundPower Routing in Modular Smart Transformers: Active Thermal Control Through Uneven Loading of Cells
Liserre, M., Andresen, M., Costa, L., & Buticchi, G. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2588898 · Cited by 112
“44 IEEE IndustrIal ElEctronIcs magazInE ■ SEPTEMBER 2016 The goal of achieving high efficiency while preserving dc connectivity is addressed with a modular ST design using power semiconductors rated for lower voltage and current [8].”
BackgroundMethodInfluentialSelf-citationLoad Control Using Sensitivity Identification by Means of Smart Transformer
De Carne, G., Buticchi, G., Liserre, M., & Vournas, C. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2614846 · Cited by 110
“The Smart Transformer is a three-stage power electronics transformer [17], [21] that adapts the voltage between the MV to the LV grid and provides new services to the distribution grid.”
BackgroundSelf-citationReverse Power Flow Control in a ST-Fed Distribution Grid
De Carne, G., Buticchi, G., Zou, Z., & Liserre, M. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2651147 · Cited by 109
“The Smart Transformer (ST) is a three-stage power electronics transformer [23], [24] that transforms the voltage from the MV to the LV grid, makes available the DC grid connections [25], provides new services to the distribution grids like the load identification and control [26], [27] and offers new solutions to curr…”
BackgroundSelf-citationA Comprehensive Assessment of Multiwinding Transformer-Based DC–DC Converters
Pereira, T., Hoffmann, F., Zhu, R., & Liserre, M. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3064302 · Cited by 114
Self-citationGupta, S., Maulik, A., Das, D., & Singh, A. P. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111861 · Cited by 111
A Review on Power Electronics Technologies for Power Quality Improvement
Afonso, J. L., Tanta, M., Pinto, J. G. O., Monteiro, L. F. C., Machado, L., Sousa, T. J. C., & Monteiro, V. (2021) · Energies · doi:10.3390/en14248585 · Cited by 119
Modeling and Control of a Two-Bus System With Grid-Forming and Grid-Following Converters
Zou, Z., Tang, J., Wang, X., Wang, Z., Chen, W., Buticchi, G., & Liserre, M. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3182366 · Cited by 103
“, lowvoltage converter of smart transformer [26]) or obtained from a Fig.”
BackgroundSelf-citationReview of MVDC Applications, Technologies, and Future Prospects
Coffey, S., Timmers, V. R. J. H., Li, R., Wu, G., & Egea‐Àlvarez, A. (2021) · Energies · doi:10.3390/en14248294 · Cited by 102
Optimum Design of a Multiple-Active-Bridge DC–DC Converter for Smart Transformer
Costa, L. F., Buticchi, G., & Liserre, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2799680 · Cited by 101
“A ST is a power electronics-based system usually composed of three conversion stages (ac–dc, dc–dc, and dc–ac) with advanced control and communication functionality [1], [2].”
BackgroundMethodInfluentialSelf-citationCosta, L. F., Hoffmann, F., Buticchi, G., & Liserre, M. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2818658 · Cited by 104
“Among them, the reverse power flow condition, storage integration, management of hybrid grids (dc and ac), and power quality improvement are highlighted [1]–[4].”
BackgroundMethodInfluentialSelf-citationSmart Transformer-Enabled Meshed Hybrid Distribution Grid
Das, D., Hrishikesan, V. M., Kumar, C., & Liserre, M. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2965489 · Cited by 94
“Smart transformer (ST) is emerging as a promising solution to handle such issues [4], [5].”
BackgroundSelf-citationShadfar, H., Pashakolaei, M. G., & Foroud, A. A. (2021) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12996 · Cited by 76
Zheng, L., Han, X., An, Z., Kandula, R. P., Kandasamy, K., Saeedifard, M., & Divan, D. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3066908 · Cited by 84
“The modularity is important from the perspective of scalability, reliability, and redundancy [9], [41]–[43].”
BackgroundSolid State Transformers: Concepts, Classification, and Control
Shamshuddin, M. A., Rojas, F., Cárdenas, R., Pereda, J. E., Díaz, M., & Kennel, R. M. (2020) · Energies · doi:10.3390/en13092319 · Cited by 98
“Phase modular SSTs presented in [19,55,77,94]: (a) using front end MMC and back end DAB in ISOP, (b) CHB with DAB in ISOP configuration, (c) QAB in ISOP configuration, and (d) interphase QAB in ISOP configuration.”
BackgroundMethodInfluentialZheng, L., Kandula, R. P., & Divan, D. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3101482 · Cited by 85
“This switch reduction scheme has been verified by being applied to derive one dc–dc CS SST and one dc–ac CS SST. Importantly, the derived CS dc SSTs with the switch reduction scheme do not have any disadvantages or penalties compared to the prior CS dc SSTs without the scheme, to the authors’ best knowledge.”
BackgroundInfluentialPugliese, S., Buticchi, G., Mastromauro, R. A., Andresen, M., Liserre, M., & Stasi, S. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2977226 · Cited by 81
“In the framework of smart grids, the ST concept has recently attracted the attention of industry for the capability to regulate the voltage, the frequency, the active and reactive power flow, and to allow meshed operations of distributed feeders [1]–[6].”
BackgroundSelf-citationMultiport Railway Power Conditioner and Its Management Control Strategy With Renewable Energy Access
Ma, F., Wang, X., Deng, L., Zhu, Z. Q., Xu, Q., & Xie, N. (2019) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2899138 · Cited by 78
“As for the isolation stage, the dualactive bridge is the practical option, but multiple active bridges (MABs) have emerged the advantage of reducing high-frequency transformers and switching devices [18], [19].”
BackgroundIntegration of Large Photovoltaic and Wind System by Means of Smart Transformer
Zhu, R., De Carne, G., Deng, F., & Liserre, M. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2701758 · Cited by 71
“The smart transformer (ST) [27], [28], instead, aims to provide ancillary services to the distribution grid [28]–[32], more than simply adapting the voltage level from MV to low voltage (LV) grids, like in the SST case.”
BackgroundSelf-citationSizing and SOC Management of a Smart-Transformer-Based Energy Storage System
Kumar, C., Zhu, R., Buticchi, G., & Liserre, M. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2784389 · Cited by 71
“In this regard, a smart transformer (ST) that is a power-electronic-based transformer equipped with an effective control, communication, and energy management capability can provide an effective solution to overcome the challenges of a complex grid [7], [8].”
BackgroundSelf-citationZheng, G., Chen, Y., & Kang, Y. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3013493 · Cited by 74
“Comparing with the traditional line frequency (LF) transformer, SSTs can not only realize interconnection between electrical systems at different voltage levels and forms, but also have the ability to provide power flow control, reactive power compensation, and fault isolation [3], [4].”
BackgroundReal-Time Primary Frequency Regulation Using Load Power Control by Smart Transformers
Carne, G. D., Buticchi, G., Liserre, M., & Vournas, C. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2888687 · Cited by 78
“The Smart Transformer is a power-electronic based transformer [23], [24], which can shape the load consumption of”
Self-citationLifetime-Based Power Routing in Parallel Converters for Smart Transformer Application
Andresen, M., Raveendran, V., Buticchi, G., & Liserre, M. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2733426 · Cited by 69
“wards compatibility with existing equipment used in the actual grid [2].”
MethodSelf-citationHighly Efficient and Reliable SiC-Based DC–DC Converter for Smart Transformer
Costa, L. F., Buticchi, G., & Liserre, M. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2696481 · Cited by 67
“However, the MFT requires high voltage isolation, as determined by the application [12], and this sets an upper limit to the operating frequency.”
BackgroundSelf-citationReduction of the Circulating Current Among Parallel NPC Inverters
Tcai, A., Kwon, Y., Pugliese, S., & Liserre, M. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3075562 · Cited by 66
Self-citationA detailed review of power system resilience enhancement pillars
Mishra, D. K., Eskandari, M., Abbasi, M. H., Sanjeevikumar, P., Zhang, J., & Li, L. (2024) · Electric Power Systems Research · doi:10.1016/j.epsr.2024.110223 · Cited by 80
Interlinking converters and their contribution to primary regulation: a review
Ordoño, A., Unamuno, E., Barrena, J. A., & Paniagua, J. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.03.057 · Cited by 72
“It has been also used in [51] and [52] to classify solid state transformer”
MethodKongjeen, Y., & Bhumkittipich, K. N. (2018) · Energies · doi:10.3390/en11061571 · Cited by 78
Liserre, M., Pérez, M. A., Langwasser, M., Rojas, C. A., & Zhou, Z. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3157162 · Cited by 71
“The ST is a power electronics-based transformer with advanced control functionalities to allow flexible ac and dc distributions, and the possibility to provide grid services [13].”
BackgroundSelf-citationOpen-Loop Power Sharing Characteristic of a Three-Port Resonant LLC Converter
École Polytechnique Fédérale de Lausanne (EPFL), L., Tran, Y., Freijedo, F. D., École Polytechnique Fédérale de Lausanne (EPFL), L., Dujić, D., & École Polytechnique Fédérale de Lausanne (EPFL), L. (2019) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2019.00017 · Cited by 67
“The SST concept includes power conversion among DC and/or AC grids of a different kind [1]–[4].”
BackgroundGao, X., Sossan, F., Christakou, K., Paolone, M., & Liserre, M. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2772181 · Cited by 60
Self-citationInterleaved Operation of Two Neutral-Point-Clamped Inverters With Reduced Circulating Current
Zou, Z., Hahn, F., Buticchi, G., Guenter, S., & Liserre, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2800402 · Cited by 58
“PARALLEL inverters are widely utilized in high-power applications, including multimegawatt wind energy systems [1], smart transformer applications [2], static synchronous compensators [3], active power filters [4], and electric drives [5].”
BackgroundSelf-citationAn Isolated Modular Multilevel Converter (I-M2C) Topology Based on High-Frequency Link (HFL) Concept
Liu, C., Liu, C., Cai, G., Ying, H., Zhang, Z., Shan, R., Pei, Z., & Song, X. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2923355 · Cited by 61
“MMC has been widely used in the SST because of its modular realization, multilevel waveform, MVac, dc ports, etc. [29], [30].”
BackgroundInfluentialZhao, Y., Zhang, G., Runrui, G., & Yang, F. (2019) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2019.007856 · Cited by 59
“THE power electronic transformer (PET), or solid-state transformer, has the potential to replace the conventional power transformer mainly due to its reduced volume and weight [1-3].”
BackgroundLifetime-Based Power Routing of a Quadruple Active Bridge DC/DC Converter
Buticchi, G., Andresen, M., Wutti, M., & Liserre, M. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2650258 · Cited by 58
“can regulate reactive power, active power (to a certain extent) for the optimization of grid feeders, integrate storage, and interact with the distributed energy sources [6].”
BackgroundMethodInfluentialSelf-citationPeak Current Control and Feed-Forward Compensation of a DAB Converter
Vázquez, N., & Liserre, M. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2949523 · Cited by 55
Self-citationA new voltage control strategy to improve performance of DSTATCOM in electric grid
Kumar, C., Mishra, M. K., & Mekhilef, S. (2020) · CES Transactions on Electrical Machines and Systems · doi:10.30941/cestems.2020.00036 · Cited by 55
IoT-Based Smart Transformer Monitoring System with Raspberry Pi
Ravindran, V., Ponraj, R. P., Krishnakumar, C., Ragunathan, S., Ramkumar, V., & Swaminathan, K. (2021) · Innovations in Power and Advanced Computing Technologies (i-PACT) · doi:10.1109/i-pact52855.2021.9696779 · Cited by 52
A Family of Series-Resonant DC–DC Converter With Fault-Tolerance Capability
Costa, L. F., Buticchi, G., & Liserre, M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2017.2757900 · Cited by 52
“In some application, such as smart transformer [1], [2], telecommunication, or even in renewable energy system, the continuity of operation is of paramount importance.”
BackgroundSelf-citationAtaullah, H., Iqbal, T., Khalil, I. U., Ali, U., Blažek, V., Prokop, L., & Ullah, N. (2022) · Energies · doi:10.3390/en15238944 · Cited by 51
Comparison of Classical and Smart Transformers Impact on MV Distribution Grid
Milczarek, A., & Malinowski, M. (2019) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2019.2941641 · Cited by 51
“Depending on the topology and used semiconductors, the ST is characterized by different efficiencies in comparision to the CT, that was investigated in publications [17], [18], [22].”
BackgroundMethodInfluentialSong, Y.-H., Yin, L., Zhong, S., Feng, Q., Wang, H., Zhang, P., Xu, H., Tong, L., & Dang, Z. (2024) · Advanced Composites and Hybrid Materials · doi:10.1007/s42114-024-00914-6 · Cited by 44
“In addition, SST is widely used in electric locomotives, car charging stations, and data centers [4, 5].”
Marquez, A., Leon, J. I., Portillo, R., Yin, J., Luo, W., Vázquez, S., Kouro, S., & Franquelo, L. G. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3000121 · Cited by 43
“The CHB topology is able to obtain a very high output voltage with an excellent waveform quality, which makes it a well-suited converter for medium- and high-voltage high-power applications [3]–[12].”
BackgroundAnalysis and Stabilization of a Smart Transformer-Fed Grid
Zou, Z.-X., Buticchi, G., & Liserre, M. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2733450 · Cited by 41
“voltage between MV and LV grids while providing ancillary services to both utility and customers [10], for instance, voltage and current profiles improvement, balancing services in MV and”
BackgroundSelf-citationComputational light junction temperature estimator for active thermal control
Andresen, M., Schloh, M., Buticchi, G., & Liserre, M. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7854953 · Cited by 42
“This calculation effort is especially critical for systems operating at high sampling frequencies and systems consisting of many power semiconductors and thus junction temperatures [8].”
BackgroundSelf-citationCarne, G. D., Liserre, M., Langwasser, M., Ndreko, M., Bachmann, R., Doncker, R. W. D., Dimitrovski, R., Mortimer, B. J., Neufeld, A., & Rojas, F. (2019) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2019.2909799 · Cited by 41
“An example of an asynchronously connected LV grid with the MV grid by means of PE is the smart transformer (ST) [37], which can limit the reverse power flow from LV in MV grids in the case of a high-RES power injection in the LV grid, controlling the power flow in the dc/dc stage.”
MethodSelf-citationSmart transformer/large flexible transformer
Zhu, R., Andresen, M., Langwasser, M., Liserre, M., Lopes, J. P., Moreira, C., Rodrigues, J., & Couto, M. (2020) · CES Transactions on Electrical Machines and Systems · doi:10.30941/cestems.2020.00033 · Cited by 41
“Thus, the update of grid assets, advanced monitoring and control techniques are needed to improve the electricity grid performances, and to further increase the penetration of renewables [3]–[5].”
BackgroundSelf-citationAn MVDC-Based Meshed Hybrid Microgrid Enabled Using Smart Transformers
Hrishikesan, V. M., Kumar, C., & Liserre, M. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3071683 · Cited by 47
“The first stage is a three-level, three-phase MV converter which connects between MVac grid and MVdc bus [10].”
BackgroundSelf-citationPan, Y., Yang, Y., He, J., Sangwongwanich, A., Zhang, C., Liu, Y., & Blaabjerg, F. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2975348 · Cited by 40
A New Fault-Tolerant Scheme for Switch Failures in Dual Active Bridge DC-DC Converter
Bhakar, P. S., & Jayaraman, K. (2022) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2022.3177345 · Cited by 44
“of the network even after sudden failures constitute the fault-tolerant (FT) feature of the converter [9], [10].”
BackgroundAnalysis of the frequency‐based control of a master/slave micro‐grid
Buticchi, G., Carne, G. D., Barater, D., Zou, Z., & Liserre, M. (2016) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2016.0167 · Cited by 40
“THE SMART TRANSFORMER CONCEPT The Smart Transformer is a three-stage power electronics transformer [19] that adapts the voltage between the MV to the LV grid and provides new services to the distribution grid.”
BackgroundSelf-citationTransformer Current Ringing in Dual Active Bridge Converters
Qin, Z., Shen, Z., Blaabjerg, F., & Bauer, P. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3040681 · Cited by 44
“Wide bandgap device-based DABs were studied in the literature not only for higher efficiency but mainly for either a higher voltage rating, such as SiC-based DAB in SSTs [2] or a more”
BackgroundInfluentialQuad-Active-Bridge Converter With Current Balancing Coupled Inductor for SST Application
Naseem, N., & Cha, H. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3076460 · Cited by 44
“In a standard operation scheme, the active H-bridges of MV side process the same amount of power [6], [7].”
BackgroundMonteiro, V., Martins, J. S., Fernandes, J. C. A., & Afonso, J. L. (2021) · Sustainability · doi:10.3390/su13169423 · Cited by 43
“In [93], the SST is meticulously investigated in terms of its impact on the power grid, as well as the inherent technological challenges, covering control and communication functions and modular structures.”
BackgroundThermal Stress Analysis of Medium-Voltage Converters for Smart Transformers
Andresen, M., Ma, K., De Carne, G., Buticchi, G., Blaabjerg, F., & Liserre, M. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2600270 · Cited by 38
“In contrast to other applications, the ST enables to partially shape its mission profile by providing services to the grid, which are not mandatory to the current state, but put loading on the devices [2].”
BackgroundSelf-citationSmart Transformer-Fed Variable Frequency Distribution Grid
Zou, Z., Carne, G. D., Buticchi, G., & Liserre, M. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2650874 · Cited by 40
“To solve these problems, the three-stage power electronic-based ST represents a promising solution [4]: it provides new features and ancillary services to distribution grids, for instance, voltage and current profiles improvement [5], balancing services in both MV and LV sides [6], load identification and control [7],…”
BackgroundSelf-citationMaulik, A. (2022) · Sustainable Energy Grids and Networks · doi:10.1016/j.segan.2022.100636 · Cited by 40
Zhu, R., Liserre, M., Langwasser, M., & Kumar, C. (2020) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2020.3005357 · Cited by 42
“The ST is a solid-state transformer with smart control functionalities as proposed in [2].”
BackgroundSelf-citationVirtual Synchronous Machine Control for Asynchronous Grid Connections
Wald, F., Tao, Q., & Carne, G. D. (2023) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2023.3235149 · Cited by 43
“Toaccount for systems of different inertia caused by the integration of renewable energy resources, the following paragraph discusses test results for frequency support of systems with inertia values of M = [4, 6].”
BackgroundInvestigation on Common-Mode Voltage Suppression in Smart Transformer-Fed Distributed Hybrid Grids
Zhu, R., Buticchi, G., & Liserre, M. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2779803 · Cited by 37
“1, where the medium voltage (MV) dc bus can be used for fast charging station, large wind and photovoltaic (PV), the low voltage (LV) dc link integrates the storage system, and both LV ac and dc grid can integrate DGs and charging station, is a candidate to enable the hybrid grids while offering ancillary services to…”
BackgroundSelf-citationDual-Purpose Converters for DC or AC Grid as Energy Transition Solution: Perspectives and Challenges
Husev, O. O., Vinnikov, D., Kouro, S., Blaabjerg, F., & Roncero‐Clemente, C. (2023) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2022.3230219 · Cited by 40
“According to recent work, a high-voltage dc current transmission system is more cost effective than a high-voltage ac system [2], [3] over longer distances [4], [5], [6].”
BackgroundHybrid distribution transformer based on a bipolar direct AC/AC converter
Kaniewski, J. (2018) · IET Electric Power Applications · doi:10.1049/iet-epa.2017.0848 · Cited by 36
Towards next generation power grid transformer for renewables: Technology review
Agarwala, A., Tahsin, T., Ali, M. F., Sarker, S. K., Abhi, S. H., Das, S. K., Das, P., Hasan, M., Tasneem, Z., Islam, M. M., et al. (2024) · Engineering Reports · doi:10.1002/eng2.12848 · Cited by 65
Grid Identification and Adaptive Voltage Control in a Smart Transformer-Fed Grid
Zou, Z., Buticchi, G., & Liserre, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2847020 · Cited by 34
“Compared to the conventional distribution transformer, the ST offers connection to hybrid grid and is able to significantly improve the demand-response balance while keeping a reasonable energy cost [1].”
BackgroundSelf-citationIncreasing Voltage Support Using Smart Power Converter Based Energy Storage System and Load Control
Hrishikesan, V. M., Das, D., Kumar, C., Gooi, H. B., Mekhilef, S., & Guo, X. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3042165 · Cited by 34
Future Distribution Networks: A Review
Javid, Z., Koçar, I., Holderbaum, W., & Karaagac, U. (2024) · Energies · doi:10.3390/en17081822 · Cited by 39
Wald, F., Hrishikesan, V. M., Gomis‐Bellmunt, O., Ji, H., Davoudi, M., Bidram, A., Syed, M. H., Joševski, M., Brüske, S., Kumar, C., et al. (2025) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2025.3574007 · Cited by 43
“High-and Low-frequency Active Filtering: The SST can maintain a balanced sinusoidal voltage at the LVAC side independent of currents demanded by non-linear loads [14], [82].”
InfluentialSelf-citationCapacity Enhancement of a Radial Distribution Grid Using Smart Transformer
Hrishikesan, V. M., Deka, A. K., & Kumar, C. (2020) · IEEE Access · doi:10.1109/access.2020.2987602 · Cited by 32
“However, in the distribution system applications, the volume and weight reduction impact is relatively small, and the efficiency, reliability plays an important role [11].”
BackgroundMethodInfluentialDiscontinuous-PWM Method for Multilevel $N$-Cell Cascaded H-Bridge Converters
Marquez, A., Monopoli, V. G., Tcai, A., Leon, J. I., Buticchi, G., Vázquez, S., Liserre, M., & Franquelo, L. G. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3016245 · Cited by 31
“sions systems, high-voltage dc transmission systems, and motor drives [4]–[7].”
BackgroundSelf-citationHannan, M. A., Ker, P. J., Mansor, M., Lipu, M. S. H., Al-Shetwi, A. Q., Alghamdi, S. M., Begum, R. A., & Kiong, T. S. (2023) · Energy Reports · doi:10.1016/j.egyr.2023.10.051 · Cited by 31
Self-Synchronizing Cascaded Inverters With Virtual Oscillator Control
Lu, M., Dutta, S., & Johnson, B. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3134662 · Cited by 30
Solid-state transformers using silicon carbide-based modular building blocks
Raju, R., Dame, M., & Steigerwald, R. (2017) · International Conference on Power Electronics and Drive Systems · doi:10.1109/peds.2017.8289295 · Cited by 20
“, where the controllability and flexible AC/DC interface of SSTs can be advantageous [1-8].”
BackgroundControl strategies for Multi-Microgrids islanding operation through Smart Transformers
Couto, M., Lopes, J. P., & Moreira, C. (2019) · Electric Power Systems Research · doi:10.1016/j.epsr.2019.105866 · Cited by 32
Bento, A., Paraiso, G. M., Costa, P. B. C., Zhang, L., Geury, T., Pinto, S. F., & Silva, J. F. (2021) · Applied Sciences · doi:10.3390/app11104597 · Cited by 31
“The need to overcome these challenges has motivated research on the topic of smart transformers [14,15] since conventional distribution transformers were mainly designed for unidirectional power flow with little to no control capabilities over the grid parameters.”
BackgroundSampling-Time Harmonic Control for Cascaded H-Bridge Converters With Thermal Control
Marquez, A., Monopoli, V. G., Leon, J. I., Ko, Y., Buticchi, G., Vázquez, S., Liserre, M., & Franquelo, L. G. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2908593 · Cited by 30
“This fact makes the CHB converter a good candidate to build the smart transformer (ST) [6], [7].”
BackgroundSelf-citationManojkumar, R., Kumar, C., Ganguly, S., Gooi, H. B., & Mekhilef, S. (2020) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2020.0213 · Cited by 29
Dao, N. D., Nguyen, H. V., & Lee, D. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3152501 · Cited by 29
“The existing SSTs can be classified based on the modular structure and the number of conversion stages [6].”
BackgroundActive Power Decoupling for Single-Phase Input–Series–Output–Parallel Solid-State Transformers
Wei, T., Cervone, A., & Dujić, D. (2024) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2024.3351618 · Cited by 32
“T HE solid-state transformer (SST) is a technology that has the potential to revolutionize many fields, including traction systems, renewable energy, data centers, and smart grids [1], [2], [3], [4], [5], [6], [7], [8], [9].”
BackgroundSelf-Repairable Smart Grids Via Online Coordination of Smart Transformers
Pournaras, E., & Espejo-Uribe, J. (2016) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2016.2625041 · Cited by 27
Zou, Z., Tang, J., Buticchi, G., & Liserre, M. (2023) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2023.3272771 · Cited by 29
“Unlike previous methods, the newly proposed ST concept, first proposed by the HEART project [20], provides another possibility to mitigate the stability issues.”
MethodSelf-citationSmart transformer-based hybrid grid loads support in partial disconnection of MV/HV power system
Kumar, C., Zou, Z., & Liserre, M. (2016) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2016.7855451 · Cited by 28
“In the recent time, one of the most enabling power electronics technology which has found its application in the distribution system is smart transformer (ST) [3]–[9].”
BackgroundSelf-citationda Silva, R. L., Borges, V. L. F., Possamai, C. E., & Barbi, I. (2020) · IEEE Access · doi:10.1109/access.2020.3013188 · Cited by 28
“There are many different designators in the literature that refer to SSTs according to each area of application, such as: Universal Power Electronics [4]; IUT - Intelligent Universal Transformer [5]; ECC - Energy Control Center [6]; Energy Router [7]; PETT - Power Electronics Traction Transformer [8]; ST - Smart Trans…”
BackgroundInfluentialZhang, L., Chen, Y., Shen, C., Tang, W. H., Liang, J., & Xu, B. (2018) · IET Generation Transmission & Distribution · doi:10.1049/iet-gtd.2018.5722 · Cited by 25
Modular Smart Transformer architectures: An overview and proposal of a interphase architecture
Costa, L. F., Buticchi, G., & Liserre, M. (2017) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2017.7972557 · Cited by 28
“Recently, Solid-State Transformer architectures have been intensively discussed in literature and classified according to the number of power stages (single-, two- or three-stages) and modularity level (non-modular, semi-modular or modular), as presented in [2].”
BackgroundInfluentialSelf-citation
Metadata
- Authors
- Liserre, M., Buticchi, G., Andresen, M., De Carne, G., Costa, L. F., & Zou, Z.-X.
- Affiliations
- Christian-Albrechts-Universität zu Kiel (DE)
- Venue
- IEEE Industrial Electronics Magazine
- Published
- 2016-06
- Volume
- 10
- Issue
- 2
- Pages
- 46-58
- ISSN
- 1932-4529 (ISSN-L)
- OpenAlex
- W2442002586
- Cited by
- 445
- References
- 34
- Citations by year
- 2026: 15 · 2025: 40 · 2024: 45 · 2023: 40 · 2022: 39 · 2021: 60 · 2020: 52 · 2019: 51 · 2018: 48 · 2017: 41 · 2016: 14
- FWCI
- 23.68
- Type
- journal article
- Language
- en
- Open access
- green
- macau.uni-kiel.de
- Locations
- IEEE Industrial Electronics Magazine (publishedVersion)
- Multimedialen Archiv und Publikationsserver der Christian-Albrechts-Universität zu Kiel (Christian-Albrechts-Universität zu Kiel) (submittedVersion)
- Multimedialen Archiv und Publikationsserver der Christian-Albrechts-Universität zu Kiel (Christian-Albrechts-Universität zu Kiel) (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid and Power Systems
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- solid-state transformer, electric distribution grid, renewable energy integration, electric vehicle charging stations, distributed generation, bidirectional information flow, electric vehicle charging infrastructure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.