Power Routing in Modular Smart Transformers: Active Thermal Control Through Uneven Loading of Cells
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Increasing decentralized energy production challenges the distribution grid [1], [2], and, in many countries, power generation and consumption are spatially separated, meaning that energy must be transferred over a long distance [3]. This calls for novel ways to transfer power to the loads without overloading grid feeders and to connect new intelligent loads and storage [4], which typically form the actual electric grid hybrid (ac and dc) and couple with other energy networks (multimodal) [5]. In the current configuration, transformers are passive devices that do not enable dc systems to connect or interface the electric grid with other energy grids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ipakchi, A., & Albuyeh, F. (2009) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2008.931384 · Cited by 1,644 · cited 1×
“Date of publication: 21 September 2016 I ncreasing decentralized energy production challenges the distribution grid [1], [2], and, in many countries, power generation and consumption are spatially separated, meaning that energy must be transferred over a long distance [3].”
BackgroundReview of Solid-State Transformer Technologies and Their Application in Power Distribution Systems
She, X., Huang, A. Q., & Burgos, R. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2277917 · Cited by 1,164
Selected failure mechanisms of modern power modules
Ciappa, M. (2002) · Microelectronics Reliability · doi:10.1016/s0026-2714(02)00042-2 · Cited by 1,039 · cited 1×
“In power electronic modules, which are commonly used to increase power density, thermal cycling affects the failure [24].”
BackgroundTransitioning to Physics-of-Failure as a Reliability Driver in Power Electronics
Wang, H., Liserre, M., Blaabjerg, F., de Place Rimmen, P., Jacobsen, J. B., Kvisgaard, T., & Landkildehus, J. (2014) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2290282 · Cited by 693
Self-citationMa, K., Liserre, M., Blaabjerg, F., & Kerekes, T. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2312335 · Cited by 460
Self-citationThe Smart Transformer: Impact on the Electric Grid and Technology Challenges
Liserre, M., Buticchi, G., Andresen, M., De Carne, G., Costa, L. F., & Zou, Z.-X. (2016) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2016.2551418 · Cited by 445 · cited 4×
“44 IEEE IndustrIal ElEctronIcs magazInE ■ SEPTEMBER 2016 The goal of achieving high efficiency while preserving dc connectivity is addressed with a modular ST design using power semiconductors rated for lower voltage and current [8].”
BackgroundMethodInfluentialSelf-citationWang, J., Huang, A., Sung, W., Liu, Y., & Baliga, B. (2009) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2009.932583 · Cited by 260 · cited 1×
“Also, a traditional transformer’s efficiency is expected to be higher than that of an SST, especially in a three-stage architecture [9].”
Background
Cited by
Junction Temperature Control for More Reliable Power Electronics
Andresen, M., Ma, K., Buticchi, G., Falck, J., Blaabjerg, F., & Liserre, M. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2665697 · Cited by 345
Self-citationCatalán, P., Wang, Y., Arza, J., & Chen, Z. (2023) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2023.3234221 · Cited by 197
“In [210], the concept of power routing with unequal load sharing”
BackgroundMethodology for Active Thermal Cycle Reduction of Power Electronic Modules
van der Broeck, C. H., Ruppert, L. A., Lorenz, R. D., & De Doncker, R. W. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2882184 · Cited by 85
“the operation strategy [40], the modulation scheme [41], or the switching frequency [27] as a function of the load to compensate thermal cycles, the trajectory is intrinsically generated”
BackgroundIntegration of Large Photovoltaic and Wind System by Means of Smart Transformer
Zhu, R., De Carne, G., Deng, F., & Liserre, M. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2701758 · Cited by 71
Self-citationHighly Efficient and Reliable SiC-Based DC–DC Converter for Smart Transformer
Costa, L. F., Buticchi, G., & Liserre, M. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2696481 · Cited by 67
Self-citationComparative analysis of MAB dc-dc converters configurations in modular smart transformer
Costa, L. F., Hoffmann, F., Buticchi, G., & Liserre, M. (2017) · 2017 IEEE 8th International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2017.7972558 · Cited by 17
“became a attractive solution in ST application, as presented in [1], [2], [8], and this converter was deeply investigated in [8], where four active bridges, named Quadruple-ActiveBridge (QAB), were employed.”
MethodSelf-citation
Metadata
- Authors
- Liserre, M., Andresen, M., Costa, L., & Buticchi, G.
- Venue
- IEEE Industrial Electronics Magazine
- Published
- 2016-09
- Volume
- 10
- Issue
- 3
- Pages
- 43-53
- ISSN
- 1932-4529 (ISSN-L)
- OpenAlex
- W2525013347
- Cited by
- 112
- References
- 7
- FWCI
- 8.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.