The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Toward Electrocorticographic Control of a Dexterous Upper Limb Prosthesis: Building Brain-Machine Interfaces
Open accessAbstract
One of the most exciting and compelling areas of research and development is building brain machine interfaces (BMIs) for controlling prosthetic limbs. Prosthetic limb technology is advancing rapidly, and the modular prosthetic limb (MPL) of the Johns Hopkins University/ Applied Physics Laboratory (JHU/APL) permits actuation with 17 degrees of freedom in 26 articulating joints. There are many signals from the brain that can be leveraged, including the spiking rates of neurons in the cortex, electrocorticographic (ECoG) signals from the surface of the cortex, and electroencephalographic (EEG) signals from the scalp. Unlike microelectrodes that record spikes, ECoG does not penetrate the cortex and has a higher spatial specificity, signal-to-noise ratio, and bandwidth than EEG signals. We have implemented an ECoG-based system for controlling the MPL in the Johns Hopkins Hospital Epilepsy Monitoring Unit, where patients are implanted with ECoG electrode grids for clinical seizure mapping and asked to perform various recorded finger or grasp movements. We have shown that low-frequency local motor potentials (LMPs) and ECoG power in the high gamma frequency (70,150 Hz) range correlate well with grasping parameters, and they stand out as good candidate features for closed-loop control of the MPL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Moreover, the high spatial and temporal resolution of ECoG and LFPs can provide finer and more accurate control signals for prostheses as the neuronal areas can be recorded independently at a higher density.[333,334]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [334]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Crone, N. (1998) · Brain · doi:10.1093/brain/121.12.2301 · Cited by 1,044
Self-citationGalán, F., Nuttin, M., Lew, E., Ferrez, P. W., Vanacker, G., Philips, J., & Millán, J. D. R. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.06.001 · Cited by 660
Active tactile exploration using a brain–machine–brain interface
O’Doherty, J. E., Lebedev, M. A., Ifft, P. J., Zhuang, K. Z., Shokur, S., Bleuler, H., & Nicolelis, M. A. L. (2011) · Nature · doi:10.1038/nature10489 · Cited by 629
Kuiken, T. A., Dumanian, G. A., Lipschutz, R. D., Miller, L. A., & Stubblefield, K. A. (2004) · Prosthetics & Orthotics International · doi:10.3109/03093640409167756 · Cited by 583
Decoding two-dimensional movement trajectories using electrocorticographic signals in humans
Schalk, G., Kubánek, J., Miller, K. J., Anderson, N. R., Leuthardt, E. C., Ojemann, J. G., Limbrick, D., Moran, D., Gerhardt, L. A., & Wolpaw, J. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/012 · Cited by 527
Induced electrocorticographic gamma activity during auditory perception
Crone, N. E., Boatman, D., Gordon, B., & Hao, L. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00545-9 · Cited by 494
Self-citationTwo-dimensional movement control using electrocorticographic signals in humans
Schalk, G., Miller, K. J., Anderson, N. R., Wilson, J. A., Smyth, M. D., Ojemann, J. G., Moran, D. W., Wolpaw, J. R., & Leuthardt, E. C. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/1/008 · Cited by 482
Electroencephalographic (EEG) control of three-dimensional movement
McFarland, D. J., Sarnacki, W. A., & Wolpaw, J. R. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/3/036007 · Cited by 454
Research works printed but not linked: 1
- 2010, Hopkins Applied Physics Lab awarded DARPA funding to test thought-controlled prosthetic limb system press release
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Parajuli, N., Sreenivasan, N., Bifulco, P., Cesarelli, M., Savino, S., Niola, V., Esposito, D., Hamilton, T. J., Naik, G. R., Gunawardana, U., et al. (2019) · Sensors · doi:10.3390/s19204596 · Cited by 332
“In other words, while EMG measures the electric current from muscles and provides the control signal according to the action intended by subject [103], brain-machine interface decodes the electrical signal generated from the brain and converts them to the control signal for the control of…”
BackgroundMcMullen, D. P., Hotson, G., Katyal, K. D., Wester, B. A., Fifer, M. S., McGee, T. G., Harris, A., Johannes, M. S., Vogelstein, R. J., Ravitz, A. D., et al. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2294685 · Cited by 188
“, those translated from neural signals [5], to actuate a coordinated sequence of movements [45].”
BackgroundSelf-citationMulti-Modal Sensing Techniques for Interfacing Hand Prostheses: A Review
Fang, Y., Hettiarachchi, N., Zhou, D., & Liu, H. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2450211 · Cited by 172
“[96]: improving the resolution of ECoG arrays, maturation of”
BackgroundInfluentialTranslating the Brain-Machine Interface
Thakor, N. V. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007303 · Cited by 128
Self-citation
Metadata
- Authors
- Fifer, M. S., Acharya, S., Benz, H. L., Mollazadeh, M., Crone, N. E., & Thakor, N. V.
- Affiliations
- Johns Hopkins University (US)
- Venue
- IEEE Pulse
- Published
- 2012-01
- Volume
- 3
- Issue
- 1
- Pages
- 38-42
- ISSN
- 2154-2287 (ISSN-L)
- PMC
- PMC3987748
- OpenAlex
- W2013619029
- Cited by
- 74
- References
- 15
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 4 · 2023: 2 · 2022: 3 · 2021: 5 · 2020: 3 · 2019: 8 · 2018: 5 · 2017: 6 · 2016: 6 · 2015: 4 · 2014: 9 · 2013: 11 · 2012: 4
- FWCI
- 4.59
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- IEEE Pulse (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Johns Hopkins University
- Defense Advanced Research Projects Agency
- National Institute of Neurological Disorders and Stroke (R01NS040596)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- electrocorticography, brain-computer interface, upper limb prosthesis, motor control, high gamma band, grasping, epilepsy monitoring, feedback control
- MeSH terms
- Animals, Artificial Limbs, Cerebral Cortex, Electrodes, Implanted, Electroencephalography, Humans, Movement, User-Computer Interface, Upper Extremity, Brain Waves
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Toward Electrocorticographic Control of a Dexterous Upper Limb Prosthesis: Building Brain-Machine Interfaces. https://app.cochat.ai/papers/10.1109/mpul.2011.2175636
- The paper
- Fifer, M. S., Acharya, S., Benz, H. L., Mollazadeh, M., Crone, N. E., & Thakor, N. V. (2012). Toward Electrocorticographic Control of a Dexterous Upper Limb Prosthesis: Building Brain-Machine Interfaces. IEEE Pulse. https://doi.org/10.1109/mpul.2011.2175636
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.