The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Compliant actuator designs
Abstract
In the growing fields of wearable robotics, rehabilitation robotics, prosthetics, and walking k robots, variable stiffness actuators (VSAs) or adjustable compliant actuators are being designed and implemented because of their ability to minimize large forces due to shocks, to safely interact with the user, and their ability to store and release energy in passive elastic elements. This review article describes the state of the art in the design of actuators with adaptable passive compliance. This new type of actuator is not preferred for classical position-controlled applications such as pick and place operations but is preferred in novel robots where safe human- robot interaction is required or in applications where energy efficiency must be increased by adapting the actuator's resonance frequency. The working principles of the different existing designs are explained and compared. The designs are divided into four groups: equilibrium-controlled stiffness, antagonistic-controlled stiffness, structure-controlled stiffness (SCS), and mechanically controlled stiffness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206
Efficient Bipedal Robots Based on Passive-Dynamic Walkers
Collins, S., Ruina, A., Tedrake, R., & Wisse, M. (2005) · Science · doi:10.1126/science.1107799 · Cited by 1,873
Measurement and modeling of McKibben pneumatic artificial muscles
Chou, C.-P., & Hannaford, B. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.481753 · Cited by 1,589
Design and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Bicchi, A., & Tonietti, G. (2004) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2004.1310939 · Cited by 654
Tonietti, G., Schiavi, R., & Bicchi, A. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570172 · Cited by 539
Robotic Orthosis Lokomat: a rehabilitation and research tool
Jezernik, S., Colombo, G., Keller, T., Frueh, H., & Morari, M. (2003) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2003.03017.x · Cited by 503 · cited 1×
“Therefore, robots that can assist in the rehabilitation process are being proposed, e.g., Lokomat [6] and Autoambulator, which impose gaitlike motion patterns to the legs of a patient.”
BackgroundZinn, M., Khatib, O., Roth, B., & Salisbury, J. K. (2004) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2004.1310938 · Cited by 409
Three Uses for Springs in Legged Locomotion
Alexander, R. M. (1990) · The International Journal of Robotics Research · doi:10.1177/027836499000900205 · Cited by 407
Cited by
Working Together: A Review on Safe Human-Robot Collaboration in Industrial Environments
Robla-Gomez, S., Becerra, V. M., Llata, J. R., Gonzalez-Sarabia, E., Torre-Ferrero, C., & Perez-Oria, J. (2017) · IEEE Access · doi:10.1109/access.2017.2773127 · Cited by 589
Materials for Smart Soft Actuator Systems
Apsite, I., Salehi, S., & Ionov, L. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00453 · Cited by 357
Stability Considerations for Variable Impedance Control
Kronander, K., & Billard, A. (2016) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2593492 · Cited by 284
Metallic molybdenum disulfide nanosheet-based electrochemical actuators
Acerce, M., Akdoğan, E. K., & Chhowalla, M. (2017) · Nature · doi:10.1038/nature23668 · Cited by 280
Adaptive Command-Filtered Backstepping Control of Robot Arms With Compliant Actuators
Pan, Y., Wang, H., Li, X., & Yu, H. (2018) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2017.2695600 · Cited by 210
Metadata
- Authors
- Ham, R., Sugar, T., Vanderborght, B., Hollander, K., & Lefeber, D.
- Venue
- IEEE Robotics & Automation Magazine
- Published
- 2009-09
- Volume
- 16
- Issue
- 3
- Pages
- 81-94
- ISSN
- 1070-9932 (ISSN-L)
- OpenAlex
- W2169100281
- Cited by
- 834
- References
- 26
- FWCI
- 19.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compliant actuator designs. https://app.cochat.ai/papers/10.1109/mra.2009.933629
- The paper
- Ham, R., Sugar, T., Vanderborght, B., Hollander, K., & Lefeber, D. (2009). Compliant actuator designs. IEEE Robotics & Automation Magazine. https://doi.org/10.1109/mra.2009.933629
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.