Abstract
Extracellular recording, the technique of inserting an electrode into the extracellular tissue of the brain to record the activity of individual neurons (“single-unit activity”), is a common experimental method used by neuroscientists to study how the brain works. In recent years, researchers have also demonstrated its potential use in medical technologies for the treatment of disorders such as paralysis, epilepsy, and memory loss. Although most of these applications require single-unit activity, these electrodes record the activity from multiple neurons surrounding the electrode. Spike sorting is the process of separating this signal into single-unit activity. A number of algorithms for this purpose have been published over the years, but there is still no universally accepted solution. In this article, we will present an overview of the spike-sorting problem, its current solutions, and the challenges that remain. Because of the increasing demand for chronically implanted spike-sorting hardware, we will also discuss implementation considerations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hodgkin, A. L., & Huxley, A. F. (1952) · The Journal of Physiology · doi:10.1113/jphysiol.1952.sp004764 · Cited by 23,191 · cited 2×
“In 1952, Hodgkin and Huxley, using an experimental technique they developed called the “voltage clamp,” made a number of groundbreaking discoveries on the movement of ions across the membranes of nerve cells during action potential generation for which they eventually received a Nobel Prize [2]–[5].”
On the Kolmogorov-Smirnov Test for Normality with Mean and Variance Unknown
Lilliefors, H. W. (1967) · Journal of the American Statistical Association · doi:10.2307/2283970 · Cited by 4,530
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 2×
“Similarly, most neural prosthetic technologies employ some sort of “decoding” algorithm—which may decode movement [11], [12], [14], intentions [15], or memories [13]—that typically operates on signals from individual neurons.”
Ferrier lecture. Functional architecture of macaque monkey visual cortex
Hubel, D. H., & Wiesel, T. N. (1977) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1977.0085 · Cited by 2,608 · cited 1×
“In 1977, Hubel and Wiesel (also Nobel Prize laureates) used electrophysiological recordings to provide the first information about how the activity of individual neurons contribute to higher visual processing [6].”
Unsupervised spike detection and sorting with wavelets and superparamagnetic clustering
Quiroga, R. Q., Nadasdy, Z., & Ben-Shaul, Y. (2004) · Neural Computation · doi:10.1162/089976604774201631 · Cited by 2,119
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 1×
“Another study showed that, while decoding is still better when single units are used, an acceptable level of performance can also be achieved using multiple units [77].”
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Restoring lost cognitive function.
Berger, T. W., Ahuja, A., Courellis, S. H., Deadwyler, S. A., Erinjippurath, G., Gerhardt, G. A., Gholmieh, G., Granacki, J. J., Hampson, R., Hsaio, M. C., et al. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511498 · Cited by 148
Cited by
Algorithm and hardware considerations for real-time neural signal on-implant processing
Zhang, Z., Savolainen, O. W., & Constandinou, T. G. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5268 · Cited by 25
High-density neural recording system design
Lee, H.-S., Eom, K., Park, M., Ku, S.-B., Lee, K., & Lee, H.-M. (2022) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00233-z · Cited by 17
Metadata
- Authors
- Gibson, S., Judy, J. W., & Markovic, D.
- Venue
- IEEE Signal Processing Magazine
- Published
- 2012-01
- Volume
- 29
- Issue
- 1
- Pages
- 124-143
- ISSN
- 1053-5888 (ISSN-L)
- OpenAlex
- W2050293473
- Cited by
- 189
- References
- 9
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.