ANGEL: An Intelligent Digital Twin Framework for Microgrid Security
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The ANGEL Digital Twin for Cyber-Physical System Security is a novel approach for improving the security of critical and non-critical infrastructure. Digital Twin technology, widely used in the aviation, manufacturing and automotive industries, has the potential to improve the security and resiliency of the microgrid. In this paper, we present a framework for adapting the Digital Twin to the application of microgrid security. The Digital Twin is a real-time, physics-based simulation that runs alongside the physical system providing for its constant monitoring and control. The Automatic Network Guardian for ELectrical systems, or ANGEL, will model both the cyber and physical layers of the microgrid and provide real-time data visualization. As a result, users will be aided in assessing the health of the physical plant and overall behavior over a range of operating conditions. The ANGEL Digital Twin will be able to use the real-time two-way coupling between the simulation and physical system to update and evolve the simulation to provide greater insight into the physical system. Ultimately ANGEL will provide the ability to diagnose and heal the physical system, mitigating both component failures and the effects of cyber attack. This paper will explain the methodology behind the design of this digital twin and the advantages of such an approach. To demonstrate the current capabilities of the ANGEL framework as a Level III digital twin, a simulation example is presented on the IEEE 39-bus benchmark.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Digital Twin Paradigm for Future NASA and U.S. Air Force Vehicles
Glaessgen, E., & Stargel, D. (2012) · 53rd AIAA/ASME/ASCE/AHS/ASC Structures, Structural Dynamics and Materials Conference 20th AIAA/ASME/AHS Adaptive Structures Conference 14th AIAA · doi:10.2514/6.2012-1818 · Cited by 3,395
Shaping the digital twin for design and production engineering
Schleich, B., Anwer, N., Mathieu, L., & Wartzack, S. (2017) · CIRP Annals · doi:10.1016/j.cirp.2017.04.040 · Cited by 1,305 · cited 1×
“More recently, the digital twin concept has been adopted by other industries that are focusing on the product lifecycle management (PLM) of consumer products such as the automotive industry, led by Tesla [17].”
BackgroundReengineering aircraft structural life prediction using a digital twin
Tuegel, E. J., Ingraffea, A. R., Eason, T. G., & Spottswood, S. M. (2011) · International Journal of Aerospace Engineering · doi:10.1155/2011/154798 · Cited by 1,119
Leveraging Digital Twin Technology in Model-Based Systems Engineering
Madni, A. M., Madni, C. C., & Lucero, S. D. (2019) · Systems · doi:10.3390/systems7010007 · Cited by 1,050 · cited 5×
“While the ANGEL digital twin framework is for a Level IV Intelligent Digital Twin, the case study presented here is using the ANGEL system after completion of first phase of the development effort.”
BackgroundInfluentialVulnerability Assessment of Cybersecurity for SCADA Systems
Ten, C.-W., Liu, C.-C., & Manimaran, G. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.2002298 · Cited by 583
Brosinsky, C., Westermann, D., & Krebs, R. (2018) · 2018 IEEE International Energy Conference (ENERGYCON) · doi:10.1109/energycon.2018.8398846 · Cited by 165
Overview of Cyberattack on Saudi Organizations
Alelyani, S., & Kumar G R, H. (2018) · Journal of Information Security and Cybercrimes Research · doi:10.26735/16587790.2018.004 · Cited by 37 · cited 1×
“The importance of the power grid coupled with the fact that malicious and state-sponsored cyberattacks are on the rise worldwide [14] makes the power grid a high value target”
Background
Cited by
Jafari, M., Kavousi-Fard, A., Chen, T., & Karimi, M. (2023) · IEEE Access · doi:10.1109/access.2023.3241588 · Cited by 409
Wang, Y., Su, Z., Guo, S., Dai, M., Luan, T. H., & Liu, Y. (2023) · IEEE Internet of Things Journal · doi:10.1109/jiot.2023.3263909 · Cited by 357
Digital Twin: A Comprehensive Survey of Security Threats
Alcaraz, C., & Lopez, J. (2022) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2022.3171465 · Cited by 340
A Survey on Digital Twin for Industrial Internet of Things: Applications, Technologies and Tools
Xu, H., Wu, J., Pan, Q., Guan, X., & Guizani, M. (2023) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2023.3297395 · Cited by 304
“For energy DT-IIoT security, Danilczyk et al. in [171] proposed a digital twin security framework for the microgrid to detect cyber attacks, such as denial-of-service attacks.”
BackgroundMicrogrid Digital Twins: Concepts, Applications, and Future Trends
Bazmohammadi, N., Madary, A., Vasquez, J. C., Mohammadi, H. B., Khan, B., Wu, Y., & Guerrero, J. M. (2022) · IEEE Access · doi:10.1109/access.2021.3138990 · Cited by 233
“In [88], a DT named ANGEL is developed for the CPS security of MGs.”
Background
Metadata
- Authors
- Danilczyk, W., Sun, Y., & He, H.
- Venue
- 2019 North American Power Symposium (NAPS)
- Publisher
- IEEE
- Published
- 2019-10
- Volume
- 2019
- Pages
- 1-6
- OpenAlex
- W3008209629
- Cited by
- 112
- References
- 7
- FWCI
- 13.18
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.