Biocompatibility evaluation of parylene C and polyimide as substrates for peripheral nerve interfaces
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
For assessing the suitability of a given material for peripheral nerve implantation, acute and chronic tests to investigate tissue reaction, and evaluate the thickness of fibroblast layers that surround the material and the presence of inflammatory cells are mandatory. In this study we compared in vivo the biocompatibility of parylene C and polyimide, two materials intended for fabrication of neural electrodes. We have tested these two materials after implantation of thin devices in the peripheral nerve of rats, by functional and morphological methods, assessing thickness of the fibrotic capsule, signs of inflammation and axon survival in areas close to the implant. Intraneural implantation of parylene C and polyimide devices did not produce any functional alteration in the sciatic nerve, as evidenced by electrophysiological, locomotion and nociceptive functional tests. The intraneural devices were encapsulated within a fibroblastic tissue. Resolution of the inflammatory infiltrate took 4-8 weeks. In conclusion, both parylene and polyimide electrodes show biocompatible characteristics and induce a similar fibrotic reaction after chronic intraneural implantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 1×
“Therefore, a biocompatible material should release no substances or substances at low, non-toxic concentrations, and the tissue should produce only mild foreign body reaction and encapsulation, without evidence of necrosis or implant rejection [4].”
BackgroundSelf-citationLago, N., Yoshida, K., Koch, K. P., & Navarro, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886617 · Cited by 227
Self-citationNanoscale neuro-integrative coatings for neural implants
He, W., & Bellamkonda, R. V. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.08.021 · Cited by 156
Thin films and microelectrode arrays for neuroprosthetics
Ordonez, J., Schuettler, M., Boehler, C., Boretius, T., & Stieglitz, T. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.117 · Cited by 118 · cited 2×
“Polyimide based electrode arrays can be used in a superficial or penetrating way [12].”
BackgroundSelf-citationInterfaces with the Peripheral Nerve for the Control of Neuroprostheses
del Valle, J., & Navarro, X. (2013) · International Review of Neurobiology · doi:10.1016/b978-0-12-420045-6.00002-x · Cited by 105
Self-citationBadia, J., Boretius, T., Pascual-Font, A., Udina, E., Stieglitz, T., & Navarro, X. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2153850 · Cited by 103
Self-citation
Cited by
Herbert, R., Kim, J.-H., Kim, Y., Lee, H., & Yeo, W.-H. (2018) · Materials · doi:10.3390/ma11020187 · Cited by 220
Long-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes
Wurth, S., Capogrosso, M., Raspopovic, S., Gandar, J., Federici, G., Kinany, N., Cutrone, A., Piersigilli, A., Pavlova, N., Guiet, R., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.014 · Cited by 176
Self-citationA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Compliant peripheral nerve interfaces.
Paggi, V., Akouissi, O., Micera, S., & Lacour, S. P. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcdbe · Cited by 60
“Sections 4.2 and 5.2 are dedicated to the strategies to reduce the FBR through different interactionmechanisms, drug eluting devices and soft biocompatible materials.”
BackgroundInfluential
Metadata
- Authors
- del Valle, J., de la Oliva, N., Muller, M., Stieglitz, T., & Navarro, X.
- Venue
- 2015 7th International IEEE/EMBS Conference on Neural Engineering (NER)
- Publisher
- IEEE
- Published
- 2015-04
- Pages
- 442-445
- ISSN
- 1948-3554 (ISSN-L)
- OpenAlex
- W1597808017
- Cited by
- 42
- References
- 6
- FWCI
- 9.94
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biocompatibility evaluation of parylene C and polyimide as substrates for peripheral nerve interfaces. https://app.cochat.ai/papers/10.1109/ner.2015.7146654
- The paper
- del Valle, J., de la Oliva, N., Muller, M., Stieglitz, T., & Navarro, X. (2015). Biocompatibility evaluation of parylene C and polyimide as substrates for peripheral nerve interfaces. 2015 7th International IEEE/EMBS Conference on Neural Engineering (NER). https://doi.org/10.1109/ner.2015.7146654
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.