Cited by 103Neuroscience and Neural EngineeringNerve injury and regenerationVagus Nerve Stimulation Research

Biocompatibility of chronically implanted transverse intrafascicular multichannel electrode (TIME) in the rat sciatic nerve

Open access
Badia, J., Boretius, T., Pascual-Font, A., Udina, E., Stieglitz, T., Navarro, X.·2011·IEEE Transactions on Biomedical Engineering

Abstract

The transverse intrafascicular multichannel electrode (TIME) is intended to be transversally implanted in the peripheral nerve and to selectively interface subsets of axons in different fascicles within the same nerve. Two versions of TIME (TIME-2, TIME-3) were designed and tested for biocompatibility and safety in the sciatic nerve of the rat. TIME-2 was implanted in two groups: one group had only an acute implant and the second group had chronic implantation for 2 months; a third group was also chronically implanted with the TIME-3 version, designed to avoid the mechanical traction produced by muscles motion. We evaluated the functional and morphological effects of either TIME-2 or TIME-3 implanted in the rat sciatic nerve for 2 months. The results of the study indicate that implantation of the TIME-2 and TIME-3 devices in the rat sciatic nerve did not cause significant axonal loss or demyelination, as evidenced by the functional and histological results. The results of this study indicate that the TIME-2 and TIME-3 designs are biocompatible and safe after chronic implantation in a small peripheral nerve, such as the rat sciatic nerve.

Integrity signals

Registry

Crossref · 10.1109/tbme.2011.2153850

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Badia, J., Boretius, T., Pascual-Font, A., Udina, E., Stieglitz, T., & Navarro, X.
Affiliations
  • University of Freiburg (DE)
  • Universitat Autònoma de Barcelona (ES)
Venue
IEEE Transactions on Biomedical Engineering
Published
2011-08
Volume
58
Issue
8
Pages
2324-2332
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2127964476
Cited by
103
References
27
Citations by year
2026: 1 · 2025: 4 · 2024: 6 · 2023: 8 · 2022: 9 · 2021: 12 · 2020: 8 · 2019: 7 · 2018: 5 · 2017: 11 · 2016: 6 · 2015: 6 · 2014: 8 · 2013: 6 · 2012: 4
FWCI
2.64
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • Zenodo (CERN European Organization for Nuclear Research) (submittedVersion, cc-by)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
  • Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
Keywords
biocompatibility, chronic implantation, sciatic nerve, peripheral nerves, axonal loss, demyelination, nerve regeneration, peripheral nerve stimulation, rat model
MeSH terms
Animals, Biocompatible Materials, Electric Conductivity, Electrodes, Implanted, Equipment Design, Materials Testing, Sciatic Nerve, Rats, Sprague-Dawley, Equipment Failure Analysis, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›