Methods for Detection and Classification of Normal Swallowing from Muscle Activation and Sound
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Swallowing is an important part of the dietary process. This paper presents an investigation to detect and classify normal swallowing during eating and drinking from electromyography and microphone sensors. The non-invasive sensors are selected in order to integrate them into a collar-like fabric for continuous monitoring of swallowing activity over a day. We compare methods for the detection of individual swallowing events from continuous sensor data. Furthermore we present a classifier comparison for the swallowing event properties volume and viscosity. The methods are evaluated on experimental data and a performance analysis is shown. Moreover we present a class skew analysis based on the metrics precision and recall
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An online algorithm for segmenting time series
Keogh, E., Chu, S., Hart, D., & Pazzani, M. (2002) · Proceedings 2001 IEEE International Conference on Data Mining · doi:10.1109/icdm.2001.989531 · Cited by 1,149 · cited 1×
“We used the Sliding-Window And Bottom-up (SWAB) algorithm [ 30 ].”
MethodAnalysis of Chewing Sounds for Dietary Monitoring
Amft, O., Stäger, M., Lukowicz, P., & Tröster, G. (2005) · Lecture Notes in Computer Science · doi:10.1007/11551201_4 · Cited by 216
Self-citationMethodology for detecting swallowing sounds
Takahashi, K., Groher, M., & Michi, K.-I. (1994) · Dysphagia · doi:10.1007/bf00262760 · Cited by 215 · cited 2×
“The microphone was secured and sealed with medical tape, following the protocol of previous investigations [11], [ 12 ], [28].”
MethodDetection of Swallowing Sounds: Methodology Revisited
Cichero, J. A. Y., & Murdoch, B. E. (2002) · Dysphagia · doi:10.1007/s00455-001-0100-x · Cited by 97
Cited by
BodyScope: a wearable acoustic sensor for activity recognition
Yatani, K., & Truong, K. N. (2012) · Proceedings of the 2012 ACM Conference on Ubiquitous Computing · doi:10.1145/2370216.2370269 · Cited by 310
“Amit and Troster used EMG sensors and a microphone to further classify the human swallowing activities [2].”
MethodRecognition of dietary activity events using on-body sensors
Amft, O., & Tröster, G. (2008) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2007.11.007 · Cited by 220
Self-citationPerformance metrics for activity recognition
Ward, J. A., Lukowicz, P., & Gellersen, H. W. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1889681.1889687 · Cited by 182
Bite Weight Prediction From Acoustic Recognition of Chewing
Amft, O., Kusserow, M., & Troster, G. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2015873 · Cited by 123
Self-citation
Metadata
- Authors
- Amft, O., & Troster, G.
- Venue
- 2006 Pervasive Health Conference and Workshops
- Publisher
- IEEE
- Published
- 2006-11
- Pages
- 1-10
- OpenAlex
- W2023240130
- Cited by
- 99
- References
- 4
- FWCI
- 30.69
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Methods for Detection and Classification of Normal Swallowing from Muscle Activation and Sound. https://app.cochat.ai/papers/10.1109/pcthealth.2006.361624
- The paper
- Amft, O., & Troster, G. (2006). Methods for Detection and Classification of Normal Swallowing from Muscle Activation and Sound. 2006 Pervasive Health Conference and Workshops. https://doi.org/10.1109/pcthealth.2006.361624
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.