A general unified approach to modelling switching-converter power stages
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A method for modelling switching-converter power stages is developed, whose starting point is the unified state-space representation of the switched networks and whose end result is either a complete state-space description or its equivalent small-signal low-frequency linear circuit model. A new canonical circuit model is proposed, whose fixed topology contains all the essential input-output and control properties of any dc-to-dc switching converter, regardless of its detailed configuration, and by which different converters can be characterized in the form of a table conveniently stored in a computer data bank to provide a useful tool for computer aided design and optimization. The new canonical circuit model predicts that, in general;switching action introduces both zeros and poles into the duty ratio to output transfer function in addition to those from the effective filter network.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Input filter considerations in design and application of switching regulators.
Middlebrook, R. D. (1976) · Medical Entomology and Zoology · Cited by 1,180
Self-citationA continuous model for the tapped-inductor boost converter
Middlebrook, R. D. (1975) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.1975.7085569 · Cited by 83
Self-citation
Cited by
Modeling and simulation of power electronic converters
Maksimovic, D., Stankovic, A. M., Thottuvelil, V. J., & Verghese, G. C. (2001) · Proceedings of the IEEE · doi:10.1109/5.931486 · Cited by 523
Cuk, S., & Middlebrook, R. D. (1977) · 1977 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.1977.7070802 · Cited by 439
Self-citationA Family of Single-Switch PWM Converters With High Step-Up Conversion Ratio
Ismail, E. H., Al-Saffar, M. A., Sabzali, A. J., & Fardoun, A. A. (2008) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2008.916427 · Cited by 359
Rodriguez, A., Vazquez, A., Lamar, D. G., Hernando, M. M., & Sebastian, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309853 · Cited by 352
Wang, J., Li, S., Yang, J., Wu, B., & Li, Q. (2015) · IET Control Theory & Applications · doi:10.1049/iet-cta.2014.0220 · Cited by 301
A natural ZVS medium-power bidirectional DC-DC converter with minimum number of devices
Li, H., Peng, F. Z., & Lawler, J. S. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.808965 · Cited by 296
“The traditional state-space averaging technique [8] and circuitFig.”
MethodZero-voltage switching in high frequency power converters using pulse width modulation
Henze, C. P., Martin, H. C., & Parsley, D. W. (2003) · APEC '88 Third Annual IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.1988.10548 · Cited by 286
Hsu, S.-P., Brown, A., Rensink, L., & Middlebrook, R. D. (1979) · 1979 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.1979.7081037 · Cited by 279
Self-citationMariéthoz, S., & Almér, S. (2012) · Advances in Industrial Control · doi:10.1007/978-1-4471-2885-4_11 · Cited by 261
A complete DC analysis of the series resonant converter
Vorperian, V., & Cuk, S. (1982) · 1982 IEEE Power Electronics Specialists conference · doi:10.1109/pesc.1982.7072398 · Cited by 213
“The switching frequency f s is given by f * s ,£ switching frequency (1)”
BackgroundSelf-citationZhang, C., Wang, J., Li, S., Wu, B., & Qian, C. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2299759 · Cited by 211
“Early control efforts for these systems are contributed to the linear control methods based on linearized models [11], but it is clear”
Zhang, K., Shan, Z., & Jatskevich, J. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2555929 · Cited by 208
A Distributed Cyber-Attack Detection Scheme With Application to DC Microgrids
Gallo, A. J., Turan, M. S., Boem, F., Parisini, T., & Ferrari-Trecate, G. (2020) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2020.2982577 · Cited by 187
“Remark 3: In the literature, the design of controllers for DCmGs with DC–DC converters often relies on the so-called state-space averaging method, to disregard the switching behavior of the terminal input [37].”
BackgroundGeneralized structure of bi-directional switched-capacitor DC/DC converters
Chung, H. S.-H., Ioinovici, A., & Cheung, W.-L. (2003) · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · doi:10.1109/tcsi.2003.812615 · Cited by 134
An Improved Generalized Average Model of DC–DC Dual Active Bridge Converters
Mueller, J. A., & Kimball, J. W. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2797966 · Cited by 118
“The upper frequency bound is, in general, imposed by the eigenvalues of the dynamic model [10], [22].”
BackgroundGuruwacharya, N., Chakraborty, S., Saraswat, G., Bryce, R., Hansen, T. M., & Tonkoski, R. (2024) · IEEE Access · doi:10.1109/access.2024.3383323 · Cited by 34
“In cases where the switching dynamics are neglected, averaging techniques (specifically state-space modeling techniques) are often employed to derive small-signal transfer function (TF) models [29].”
MethodDesign and implementation of the control of an MMC-based solid state transformer
Lopez, M., Rodriguez, A., Blanco, E., Saeed, M., Martinez, A., & Briz, F. (2015) · 2015 IEEE 13th International Conference on Industrial Informatics (INDIN) · doi:10.1109/indin.2015.7281970 · Cited by 24
Metadata
- Authors
- Middlebrook, R. D., & Cuk, S.
- Venue
- 1976 IEEE Power Electronics Specialists Conference
- Publisher
- IEEE
- Published
- 1976-06
- Pages
- 18-34
- ISSN
- 0275-9306 (ISSN-L)
- OpenAlex
- W2103792123
- Cited by
- 1,790
- References
- 2
- FWCI
- 15.31
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.