Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 206

The DOI matches its Crossref record.

Static synchronous generators for distributed generation and renewable energy

Zhong, Qing-Chang, Weiss, George · 2009 · 2009 IEEE/PES Power Systems Conference and Exposition

Abstract

In this paper, the idea of operating an inverter as a synchronous generator is developed after establishing a model for synchronous generators to cover all dynamics without any assumptions on the signals. The inverters which are operated in this way are called static synchronous generators (SSG). This means that the well-established theory/device for synchronous generators can still be used for inverters, which will dominate the power generation in the future because of the increasing share of distributed generation sources and renewable energy sources utilised. The power of an SSG can be regulated using the well-known frequency and voltage drooping mechanism. SSGs can also be easily operated in grid-connected mode or island mode. Simulation results are given to verify the idea.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/psce.2009.4840013

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 206

Metadata

Authors
Zhong, Q.-C., & Weiss, G.
Venue
2009 IEEE/PES Power Systems Conference and Exposition
Publisher
IEEE
Published
2009-03
Pages
1-6
OpenAlex
W2009636257
Cited by
206
References
0
FWCI
10.63
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Static synchronous generators for distributed generation and renewable energy. https://app.cochat.ai/papers/10.1109/psce.2009.4840013
The paper
Zhong, Q.-C., & Weiss, G. (2009). Static synchronous generators for distributed generation and renewable energy. 2009 IEEE/PES Power Systems Conference and Exposition. https://doi.org/10.1109/psce.2009.4840013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.