The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Virtual synchronous machines — Classification of implementations and analysis of equivalence to droop controllers for microgrids
Abstract
The concept of Virtual Synchronous Machines (VSM) is emerging as an alternative approach for control of power electronic converters operating in the power system. One main motivation for applying VSM-based control is to achieve a simple approach for emulating the inertia effect of traditional synchronous machines. This paper provides a comprehensive literature review on VSM and a possible classification of the different schemes. In addition, the small-signal response of the inertia emulation characteristics of VSM-based control is proved to be equivalent to conventional droop-based control for standalone and microgrid operation of converters. Thus, the droop gain and the filter time constant of the power feedback in a droop controller can be directly related to the damping factor and the inertia constant of a Virtual Synchronous Machine. The derived results are providing additional physics-based insight into the operation and tuning of both types of controllers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Control of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723
Grid Converters for Photovoltaic and Wind Power Systems
Teodorescu, R., Liserre, M., & Rodríguez, P. (2011) · Wiley eBooks · doi:10.1002/9780470667057 · Cited by 3,344
Synchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107
Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018
A Voltage and Frequency Droop Control Method for Parallel Inverters
De Brabandere, K., Bolsens, B., Van den Keybus, J., Woyte, A., Driesen, J., & Belmans, R. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.900456 · Cited by 1,865
Control of parallel connected inverters in standalone AC supply systems
Chandorkar, M. C., Divan, D. M., & Adapa, R. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.195899 · Cited by 1,766
Power-Synchronization Control of Grid-Connected Voltage-Source Converters
Zhang, L., Harnefors, L., & Nee, H.-P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2032231 · Cited by 1,317
Beck, H.-P., & Hesse, R. (2007) · 2007 9th International Conference on Electrical Power Quality and Utilisation · doi:10.1109/epqu.2007.4424220 · Cited by 1,097
Yao, W., Chen, M., Matas, J., Guerrero, J. M., & Qian, Z.-M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2046001 · Cited by 844
Cited by
Foundations and Challenges of Low-Inertia Systems (Invited Paper)
Milano, F., Dörfler, F., Hug, G., Hill, D. J., & Verbič, G. (2018) · 2018 Power Systems Computation Conference (PSCC) · doi:10.23919/pscc.2018.8450880 · Cited by 1,039
D’Arco, S., Suul, J. A., & Fosso, O. B. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2015.01.001 · Cited by 704
Self-citationVirtual Inertia: Current Trends and Future Directions
Tamrakar, U., Shrestha, D., Maharjan, M., Bhattarai, B., Hansen, T., & Tonkoski, R. (2017) · Applied Sciences · doi:10.3390/app7070654 · Cited by 640
Future low-inertia power systems: Requirements, issues, and solutions - A review
Ratnam, K. S., Palanisamy, K., & Yang, G. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.109773 · Cited by 474
Current Limiting Control With Enhanced Dynamics of Grid-Forming Converters During Fault Conditions
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931477 · Cited by 466
Metadata
- Authors
- D'Arco, S., & Suul, J. A.
- Venue
- 2013 IEEE Grenoble Conference
- Publisher
- IEEE
- Published
- 2013-06
- Pages
- 1-7
- OpenAlex
- W2007949701
- Cited by
- 443
- References
- 21
- FWCI
- 18.28
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Virtual synchronous machines — Classification of implementations and analysis of equivalence to droop controllers for microgrids. https://app.cochat.ai/papers/10.1109/ptc.2013.6652456
- The paper
- D'Arco, S., & Suul, J. A. (2013). Virtual synchronous machines — Classification of implementations and analysis of equivalence to droop controllers for microgrids. 2013 IEEE Grenoble Conference. https://doi.org/10.1109/ptc.2013.6652456
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.