The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Capsule Endoscopy: From Current Achievements to Open Challenges
Abstract
Wireless capsule endoscopy (WCE) can be considered an example of disruptive technology since it represents an appealing alternative to traditional diagnostic techniques. This technology enables inspection of the digestive system without discomfort or need for sedation, thus preventing the risks of conventional endoscopy, and has the potential of encouraging patients to undergo gastrointestinal (GI) tract examinations. However, currently available clinical products are passive devices whose locomotion is driven by natural peristalsis, with the drawback of failing to capture the images of important GI tract regions, since the doctor is unable to control the capsule's motion and orientation. To address these limitations, many research groups are working to develop active locomotion devices that allow capsule endoscopy to be performed in a totally controlled manner. This would enable the doctor to steer the capsule towards interesting pathological areas and to accomplish medical tasks. This review presents a research update on WCE and describes the state of the art of the basic modules of current swallowable devices, together with a perspective on WCE potential for screening, diagnostic, and therapeutic endoscopic procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
OctoMag: An Electromagnetic System for 5-DOF Wireless Micromanipulation
Kummer, M. P., Abbott, J. J., Kratochvil, B. E., Borer, R., Sengul, A., & Nelson, B. J. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2073030 · Cited by 1,161
Martel, S., Mohammadi, M., Felfoul, O., Lu, Z., & Pouponneau, P. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364908100924 · Cited by 461
Capsule Endoscopy versus Colonoscopy for the Detection of Polyps and Cancer
Van Gossum, A., Munoz-Navas, M., Fernandez-Urien, I., Carretero, C., Gay, G., Delvaux, M., Lapalus, M. G., Ponchon, T., Neuhaus, H., Philipper, M., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0806347 · Cited by 368
The Risk of Retention of the Capsule Endoscope in Patients with Known or Suspected Crohn's Disease
Cheifetz, A. S., Kornbluth, A. A., Legnani, P., Schmelkin, I., Brown, A., Lichtiger, S., & Lewis, B. S. (2006) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2006.00761.x · Cited by 364
Ciuti, G., Valdastri, P., Menciassi, A., & Dario, P. (2010) · Robotica · doi:10.1017/s0263574709990361 · Cited by 306
Self-citationModeling Magnetic Torque and Force for Controlled Manipulation of Soft-Magnetic Bodies
Abbott, J. J., Ergeneman, O., Kummer, M. P., Hirt, A. M., & Nelson, B. J. (2007) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.910775 · Cited by 290
Kim, B., Lee, S., Park, J. H., & Park, J.-O. (2005) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2004.842222 · Cited by 267
Polla, D. L., Erdman, A. G., Robbins, W. P., Markus, D. T., Diaz-Diaz, J., Rizq, R., Nam, Y., Brickner, H. T., Wang, A., & Krulevitch, P. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.551 · Cited by 220
An inductive power link for a wireless endoscope
Lenaerts, B., & Puers, R. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.06.015 · Cited by 204
Cited by
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
Biomedical Applications of Untethered Mobile Milli/Microrobots
Sitti, M., Ceylan, H., Hu, W., Giltinan, J., Turan, M., Yim, S., & Diller, E. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2385105 · Cited by 893
Medical Robotics and Computer-Integrated Surgery
Taylor, R. H., Menciassi, A., Fichtinger, G., Fiorini, P., & Dario, P. (2016) · Springer Handbooks · doi:10.1007/978-3-319-32552-1_63 · Cited by 325
Self-citationvan Wijck, K., Lenaerts, K., Grootjans, J., Wijnands, K. A. P., Poeze, M., van Loon, L. J. C., Dejong, C. H. C., & Buurman, W. A. (2012) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00066.2012 · Cited by 285
Charthad, J., Weber, M. J., Chang, T. C., & Arbabian, A. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2427336 · Cited by 245
Metadata
- Authors
- Ciuti, G., Menciassi, A., & Dario, P.
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2011
- Volume
- 4
- Pages
- 59-72
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W2146704338
- Cited by
- 466
- References
- 37
- FWCI
- 21.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capsule Endoscopy: From Current Achievements to Open Challenges. https://app.cochat.ai/papers/10.1109/rbme.2011.2171182
- The paper
- Ciuti, G., Menciassi, A., & Dario, P. (2011). Capsule Endoscopy: From Current Achievements to Open Challenges. IEEE Reviews in Biomedical Engineering. https://doi.org/10.1109/rbme.2011.2171182
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.