Abstract

A first proof-of-concept mm-sized implantable device using ultrasonic power transfer and a hybrid bi-directional data communication link is presented. Ultrasonic power transfer enables miniaturization of the implant and operation deep inside the body, while still achieving safe and high power levels (100 μW to a few mWs) required for most implant applications. The current implant prototype measures 4 mm ×7.8 mm and is comprised of a piezoelectric receiver, an IC designed in 65 nm CMOS process and an off-chip antenna. The IC can support a maximum DC load of 100 μW for an incident acoustic intensity that is ~ 5% of the FDA diagnostic limit. This demonstrates the feasibility of providing further higher available DC power, potentially opening up new implant applications. The proposed hybrid bi-directional data link consists of ultrasonic downlink and RF uplink. Falling edge of the ultrasound input is detected as downlink data. The implant transmits an ultra-wideband (UWB) pulse sequence as uplink data, demonstrating capability of implementing an energy-efficient M-ary PPM transmitter in the future.

Integrity signals

Registry

Crossref · 10.1109/jssc.2015.2427336

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Higher available DC power levels between 100 μW and a few mWs are feasible.

    “This implant supported a DC load up to 100 μW, suggesting the feasibility for higher available DC power levels between 100 μW to a few mWs (Charthad et al., 2015).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Charthad et al., 2015

  • A Stanford implant with dimensions 4 mm × 7.8 mm operated at an incident acoustic intensity within 5% of the FDA diagnostic limit.

    “For example researchers at Stanford University featured an implant with dimensions of 4 mm × 7.8 mm that operated at an incident acoustic intensity within 5% of the FDA diagnostic limit.”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Charthad et al., 2015

  • The Stanford implant supported a DC load up to 100 μW.

    “This implant supported a DC load up to 100 μW, suggesting the feasibility for higher available DC power levels between 100 μW to a few mWs (Charthad et al., 2015).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Charthad et al., 2015

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Charthad, J., Weber, M. J., Chang, T. C., & Arbabian, A.
Affiliations
Stanford University (US)
Venue
IEEE Journal of Solid-State Circuits
Published
2015-08
Volume
50
Issue
8
Pages
1741-1753
ISSN
  • 0018-9200 (ISSN-L)
  • 1558-173X
OpenAlex
W1583855207
Cited by
245
References
40
Citations by year
2026: 10 · 2025: 18 · 2024: 22 · 2023: 23 · 2022: 20 · 2021: 31 · 2020: 31 · 2019: 20 · 2018: 27 · 2017: 24 · 2016: 17 · 2015: 2
FWCI
11.61
Type
journal article
Language
en
Open access
closed
Locations
IEEE Journal of Solid-State Circuits (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
Keywords
biomedical implants, ultrasonic power transfer, piezoelectric receiver, M-ary pulse position modulation, energy-efficient transmitter, 65 nm CMOS, device miniaturization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review