Comparative analysis of dual active bridge isolated DC to DC converter with flyback converters for bidirectional energy transfer
The DOI matches its Crossref record; 11 of the 12 references it cites were found in a registry or an index.
Abstract
Bidirectional energy transfer capability is the central part of a lot of modern power conversion systems. Preferably, for reduction of size, weight and cost these systems use a single high efficiency power electronic conversion system. A dual active bridge converter having two DC-AC converters connected back to back through an AC inductor/transformer is a common topology used for obtaining high efficiency bidirectional power conversion. Some characteristic features of the DAB converter topology are bidirectional power flow capability, inherent soft switching, high power density, high efficiency, galvanic isolation and low number of passive components. In this paper, comparative study of Dual active bridge converter is done with flyback converters. Also efficiency of these converters are compared. Switching of devices for the two converters is also shown. Flyback converter is operated in both buck as well as boost mode. DAB is simulated in SPS (Single phase shift) mode.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Bai, H., & Mi, C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005103 · Cited by 1,121
A Bidirectional DC–DC Converter for an Energy Storage System With Galvanic Isolation
Inoue, S., & Akagi, H. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.909248 · Cited by 780
Engel, S. P., Stieneker, M., Soltau, N., Rabiee, S., Stagge, H., & De Doncker, R. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2310656 · Cited by 443
Weise, N. D., Castelino, G., Basu, K., & Mohan, N. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2293112 · Cited by 223
Closed-Loop Control of DC–DC Dual-Active-Bridge Converters Driving Single-Phase Inverters
Qin, H., & Kimball, J. W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2257859 · Cited by 212
Zhao, B., Song, Q., Li, J., Wang, Y., & Liu, W. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2558660 · Cited by 170
Riedel, J., Holmes, D. G., McGrath, B. P., & Teixeira, C. (2017) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2016.2573856 · Cited by 119
Shi, X., Jiang, J., & Guo, X. (2012) · Energies · doi:10.3390/en6010027 · Cited by 47
Basic families of medium-power soft-switched isolated bidirectional dc-dc converters
Karshenas, H. R., Daneshpajooh, H., Safaee, A., Bakhshai, A., & Jain, P. K. (2011) · Power Electronics, Drive Systems, and Technologies Conference (PEDSTC) · doi:10.1109/pedstc.2011.5742504 · Cited by 39
Research works printed but not linked: 1
- riedal, 2017, ZVS Soft Switching Boundaries for Dual ActiveBridge DC-DC Converters Using FrequencyDomain Analysis, IEEE Transactions on Power Electronics, 32
Cited by
Wang, J., Wang, B., Zhang, L., Wang, J., Shchurov, N. I., & Malozyomov, B. V. (2022) · Green Energy and Intelligent Transportation · doi:10.1016/j.geits.2022.100010 · Cited by 153
Tong, Y., Salhi, I., Wang, Q., Lu, G., & Wu, S. (2025) · Energies · doi:10.3390/en18092312 · Cited by 60
“Isolated bidirectional converters, in this context, have become an ideal solution for energy conversion in EVs [61].”
Efficient DC–DC power converters for fuel‐cell electric vehicle: A qualitative assessment
Kumar, S., Jammeh, S., Samb, R., & Singh, A. P. (2024) · IET Power Electronics · doi:10.1049/pel2.12819 · Cited by 25
Alrubaie, A. J., Swadi, M., Salem, M., Richelli, A., Bughneda, A., & Jamil, M. K. M. (2024) · Energies · doi:10.3390/en17071575 · Cited by 27
A Three-Phase Isolated Building Block for High-Power Medium-Voltage Grid Applications
Gomez, R. A., Porras, D. A., Oggier, G. G., Balda, J. C., & Zhao, Y. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2023.3311775 · Cited by 16
“…blocking capacity of these new devices allows for simpler two-level converter modules like the dual-active bridge (DAB), having high power density, efficiency, soft switching within a certain range, galvanic isolation, simple control strategy, buck-boost operation, and high reliability [19], [20].”
BackgroundManoj, K. M. B., & Padmavathi, K. (2023) · International Conference on Advances in Electrical, Electronics and Computational Intelligence (ICAEECI) · doi:10.1109/icaeeci58247.2023.10370982 · Cited by 7
Zabetian‐Hosseini, A., Ghazanfari, A., & Boulet, B. (2024) · Battery energy · doi:10.1002/bte2.20230055 · Cited by 7
Study of a soft switched Isolated DC-DC Bidirectional Converter for Electric Vehicles
Parida, A., Barai, M., & Mothukuri, K. R. (2019) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2019.8929644 · Cited by 4
A Novel Isolated DC-DC Converter with Configurable Structure for Wide Output Voltage Range Operation
Li, W., Qu, Y., Du, Y., Zhang, Y., & Liu, Y. (2023) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg56097.2023.10215197 · Cited by 3
“Therefore, the efficiency of DAB is high [13-15].”
BackgroundNovel Resonant Bidirectional DC–DC Converter Based on Asymmetrical Half-Bridge Flyback
Cruz-Cozar, J., Perez-Martinez, J., Medina-Garcia, A., Martos-Contreras, C., Rodríguez, N., & Morales, D. P. (2026) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2026.3666075 · Cited by 3
“Flyback-based converters have a reduced bill of materials and low complexity, but they suffer from high voltage stress in the components, together with a bulky transformer which has to store all the transferred energy [9].”
A 3rd Gen 10-kV SiC MOSFET High-Frequency Power Conversion Block for MV Applications
Gomez, R. A., Balda, J. C., & Zhao, Y. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362260 · Cited by 2
Karvekar, S., & Joshi, P. M. (2023) · World Journal of Engineering · doi:10.1108/wje-12-2022-0478 · Cited by 1
Shaikh, S. A., Bagewadi, M. D., & Shaikh, S. (2022) · International Conference on Emerging Trends in Engineering and Medical Sciences (ICETEMS) · doi:10.1109/icetems56252.2022.10093250
Comparative analysis of various materials for linear switched reluctance motor applied in railways
Kumar, A. A., Rathore, A., & Prasad, N. (2023) · Materials Today Proceedings · doi:10.1016/j.matpr.2023.07.128
Self-citation
Metadata
- Authors
- Kumar, A., Bhat, A. H., & Agarwal, P.
- Affiliations
- Indian Institute of Technology Roorkee (IN)
- Venue
- 2017 Recent Developments in Control, Automation & Power Engineering (RDCAPE)
- Publisher
- IEEE
- Published
- 2017-10
- Pages
- 382-387
- OpenAlex
- W2800213370
- Cited by
- 14
- References
- 12
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 3 · 2023: 6 · 2022: 2 · 2019: 1
- FWCI
- 0.39
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Conference on Recent Developments in Control, Automation & Power Engineering (RDCAPE) (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Keywords
- dual active bridge converter, flyback converter, bidirectional energy flow, DC-DC conversion, soft switching, galvanic isolation, converter efficiency, buck and boost operation, power density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.