The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electroadhesive robots—wall climbing robots enabled by a novel, robust, and electrically controllable adhesion technology
Abstract
This paper describes a novel clamping technology called compliant electroadhesion, as well as the first application of this technology to wall climbing robots. As the name implies, electroadhesion is an electrically controllable adhesion technology. It involves inducing electrostatic charges on a wall substrate using a power supply connected to compliant pads situated on the moving robot. High clamping forces (0.2-1.4 Newton supported by 1 square centimeter of clamp area, depending on substrate) have been demonstrated on a wide variety of common building substrates, both rough and smooth as well as both electrically conductive and insulating. Unlike conventional adhesives or dry adhesives, the electroadhesion can be modulated or turned off for mobility or cleaning. The technology uses a very small amount of power (on the order of 20 microwatts/Newton weight held) and shows the ability to repeatably clamp to wall substrates that are heavily covered in dust or other debris. Using this technology, SRI International has demonstrated a variety of wall climbing robots including tracked and legged robots.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RHex: A Simple and Highly Mobile Hexapod Robot
Saranli, U., Buehler, M., & Koditschek, D. E. (2001) · The International Journal of Robotics Research · doi:10.1177/02783640122067570 · Cited by 1,322
Cited by
Ultrathin and lightweight organic solar cells with high flexibility
Kaltenbrunner, M., White, M. S., Głowacki, E. D., Sekitani, T., Someya, T., Sariciftci, N. S., & Bauer, S. (2012) · Nature Communications · doi:10.1038/ncomms1772 · Cited by 1,757
Gu, G., Zou, J., Zhao, R., Zhao, X., & Zhu, X. (2018) · Science Robotics · doi:10.1126/scirobotics.aat2874 · Cited by 687
Recent progress in flexible–wearable solar cells for self-powered electronic devices
Hashemi, S. A., Ramakrishna, S., & Aberle, A. G. (2020) · Energy & Environmental Science · doi:10.1039/c9ee03046h · Cited by 527
Waalbot II: Adhesion Recovery and Improved Performance of a Climbing Robot using Fibrillar Adhesives
Murphy, M. P., Kute, C., Mengüç, Y., & Sitti, M. (2011) · The International Journal of Robotics Research · doi:10.1177/0278364910382862 · Cited by 247
A tailless timing belt climbing platform utilizing dry adhesives with mushroom caps
Krahn, J., Liu, Y., Sadeghi, A., & Menon, C. (2011) · Smart Materials and Structures · doi:10.1088/0964-1726/20/11/115021 · Cited by 67
Metadata
- Authors
- Prahlad, H., Pelrine, R., Stanford, S., Marlow, J., & Kornbluh, R.
- Venue
- 2008 IEEE International Conference on Robotics and Automation
- Publisher
- IEEE
- Published
- 2008-05
- Pages
- 3028-3033
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2156398583
- Cited by
- 278
- References
- 1
- FWCI
- 61.76
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electroadhesive robots—wall climbing robots enabled by a novel, robust, and electrically controllable adhesion technology. https://app.cochat.ai/papers/10.1109/robot.2008.4543670
- The paper
- Prahlad, H., Pelrine, R., Stanford, S., Marlow, J., & Kornbluh, R. (2008). Electroadhesive robots—wall climbing robots enabled by a novel, robust, and electrically controllable adhesion technology. 2008 IEEE International Conference on Robotics and Automation. https://doi.org/10.1109/robot.2008.4543670
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.