A comparison of wearable and stationary sensors for stress detection
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
To test the stress detection performance of a wearable sensor system, the signals related to heart activity and electrodermal activity of the Empatica E4 wristband have been compared to stationary electrocardiogram and finger skin conductivity electrodes of high sampling rates during the classical laboratory stress protocol Trier Social Stress Test. The comparison has been done on both signal level and in terms of features for stress detection on a total of seven subjects. The main results point out that the Empatica E4 wristband had a significant loss in terms of detected interbeat intervals, but that time-domain features such as the mean heart rate and standard deviation of the heart rate were still well estimated, with good stress discrimination power. Furthermore, the skin conductivity signals measured at different locations (wrist versus finger) show no visual resemblance and it appears that the signal from the Empatica E4 wristband yielded higher stress discrimination power than the signal measured at the fingers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“The ECG peaks were detected using the PanTompkins algorithm [15].”
MethodKirschbaum, C., Pirke, K.-M., & Hellhammer, D. H. (2008) · Neuropsychobiology · doi:10.1159/000119004 · Cited by 6,093
(2001) · doi:10.1017/cbo9780511546396 · Cited by 4,482
Kubios HRV–heart rate variability analysis software.
Tarvainen, M. P., Niskanen, J.-P., Lipponen, J. A., Ranta-aho, P. O., & Karjalainen, P. A. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2013.07.024 · Cited by 2,720
Detecting Stress During Real-World Driving Tasks Using Physiological Sensors
Healey, J. A., & Picard, R. W. (2005) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2005.848368 · Cited by 2,207
Discriminating Stress From Cognitive Load Using a Wearable EDA Device
Setz, C., Arnrich, B., Schumm, J., La Marca, R., Troster, G., & Ehlert, U. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2036164 · Cited by 742 · cited 1×
“The Emotion Board wearable device for measuring electrodermal activity was tested by [9], reaching a maximum accuracy of 82.”
MethodDevelopment and Evaluation of an Ambulatory Stress Monitor Based on Wearable Sensors
Choi, J., Ahmed, B., & Gutierrez-Osuna, R. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2169804 · Cited by 221
Cited by
Stress detection in daily life scenarios using smart phones and wearable sensors: A survey
Can, Y. S., Arnrich, B., & Ersoy, C. (2019) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2019.103139 · Cited by 476
Schuurmans, A. A. T., de Looff, P., Nijhof, K. S., Rosada, C., Scholte, R. H. J., Popma, A., & Otten, R. (2020) · Journal of Medical Systems · doi:10.1007/s10916-020-01648-w · Cited by 210
“[9], and Zheng and Poon [20] were conducted with small sample sizes ranging from one to seven participants.”
BackgroundMethodResultInfluentialMilstein, N., & Gordon, I. (2020) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2020.00148 · Cited by 180
Stressing the accuracy: Wrist‐worn wearable sensor validation over different conditions
Menghini, L., Gianfranchi, E., Cellini, N., Patron, E., Tagliabue, M., & Sarlo, M. (2019) · Psychophysiology · doi:10.1111/psyp.13441 · Cited by 157
Bolinski, F., Etzelmüller, A., De Witte, N. A. J., van Beurden, C., Debard, G., Bonroy, B., Cuijpers, P., Riper, H., & Kleiboer, A. (2021) · Behaviour Research and Therapy · doi:10.1016/j.brat.2021.103877 · Cited by 23
Metadata
- Authors
- Ollander, S., Godin, C., Campagne, A., & Charbonnier, S.
- Venue
- 2016 IEEE International Conference on Systems, Man, and Cybernetics (SMC)
- Publisher
- IEEE
- Published
- 2016-10
- Pages
- 004362-004366
- ISSN
- 1062-922X (ISSN-L)
- OpenAlex
- W2587035538
- Cited by
- 131
- References
- 7
- FWCI
- 6.97
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.