A high-yield IC-compatible multichannel recording array

Najafi, K., Wise, K.D., Mochizuki, T. · 1985 · IEEE Transactions on Electron Devices

Abstract

This paper reports the development of a multielectrode recording array for use in studies of information processing in the central nervous system and in the closed-loop control of neural prostheses. The probe utilizes a silicon supporting carrier which is defined using a deep boron diffusion and an anisotropic etch stop. This substrate supports an array of polysilicon or tantalum thin-film conductors insulated above and below with silicon nitride and silicon dioxide. Typical probe dimensions include a length of 3 mm, shank width of 50 µm, and a thickness of 15 µm. These structures are capable of simultaneous high-amplitude multichannel recording of neural activity in the cortex. The probe fabrication process requires only four masks and is single-sided using wafers of normal thickness, resulting in yields which exceed 80 percent. The process is also compatible with the inclusion of on-chip MOS circuitry for signal amplification and multiplexing. A complete ten-channel signal processor which requires only three external probe leads is being developed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/t-ed.1985.22102

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. 1977, Functional Electrical Stimulation Applications in Neural Prostheses

Cited by

See all 301

Metadata

Authors
Najafi, K., Wise, K. D., & Mochizuki, T.
Venue
IEEE Transactions on Electron Devices
Published
1985-07
Volume
32
Issue
7
Pages
1206-1211
ISSN
  • 0018-9383 (ISSN-L)
  • 1557-9646
OpenAlex
W2045701127
Cited by
301
References
11
FWCI
1.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.