Transducers Using Forced Transitions Between Ferroelectric and Antiferroelectric States
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The use of resonant piezoelectric composite structures for acoustic radiation into fluid media is well established. At low frequencies, desirable for long distance acoustic transmission, resonant structures are extremely large and expensive. Frequency lowering can be accomplished by a variety of means involving use of bending structures or mass-loading, but the resulting transducers are vulnerable to pressure effects due to deep submersion. A possible alternative to present transducer structures is the use of the electric field-forced transition from antiferroelectric to ferroelectric. A number of Pb(Zr, Sn, Ti)O3 compositions have been developed which experience these transitions at relatively low electric field(7-15 kV/cm) and typically generate volume strains near 0.1%. There is therefore not necessarily a requirement for acoustic shielding, and since the developed strain is independent of frequency, resonant structures are not needed. Construction is therefore simplified and the size and weight of low frequency transducers may be reduced. Operating characteristics of the antiferroelectric transducer are discussed in detail, but no large low frequency transducer arrays have yet been built.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ferroelectricity versus Antiferroelectricity in the Solid Solutions of PbZrO3and PbTiO3
Sawaguchi, E. (1953) · Journal of the Physical Society of Japan · doi:10.1143/jpsj.8.615 · Cited by 541
Dielectric Properties of Lead Zirconate
Shirane, G., Sawaguchi, E., & Takagi, Y. (1951) · Physical Review · doi:10.1103/physrev.84.476 · Cited by 418
Berlincourt, D., Krueger, H. H. A., & Jaffe, B. S. (1964) · Journal of Physics and Chemistry of Solids · doi:10.1016/0022-3697(64)90175-1 · Cited by 334
Self-citationAntiferroelectric Ceramics with Field-Enforced Transitions: A New Nonlinear Circuit Element
Jaffe, B. (1961) · Proceedings of the IRE · doi:10.1109/jrproc.1961.287917 · Cited by 191
Effects of High Static Stress on the Piezoelectric Properties of Transducer Materials
Krueger, H. H. A., & Berlincourt, D. (1961) · The Journal of the Acoustical Society of America · doi:10.1121/1.1908435 · Cited by 91
Self-citation
Cited by
Jin, L., Li, F., & Zhang, S. (2014) · Journal of the American Ceramic Society · doi:10.1111/jace.12773 · Cited by 1,229
Progress in high-strain perovskite piezoelectric ceramics
Hao, J., Li, W., Zhai, J., & Chen, H. (2019) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2018.08.001 · Cited by 840
A comprehensive review on the progress of lead zirconate-based antiferroelectric materials
Hao, X., Zhai, J., Kong, L. B., & Xu, Z. (2014) · Progress in Materials Science · doi:10.1016/j.pmatsci.2014.01.002 · Cited by 782
Tan, X., Ma, C., Frederick, J., Beckman, S., & Webber, K. G. (2011) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2011.04917.x · Cited by 400
Antiferroelectricity in thin-filmZrO2from first principles
Reyes-Lillo, S. E., Garrity, K. F., & Rabe, K. M. (2014) · Physical Review B · doi:10.1103/physrevb.90.140103 · Cited by 287
Hao, X., Wang, Y., Zhang, L., Zhang, L., & An, S. (2013) · Applied Physics Letters · doi:10.1063/1.4802794 · Cited by 186
Sharifzadeh Mirshekarloo, M., Yao, K., & Sritharan, T. (2010) · Applied Physics Letters · doi:10.1063/1.3497193 · Cited by 186
Xu, B., Ye, Y., Wang, Q.-M., & Cross, L. E. (1999) · Journal of Applied Physics · doi:10.1063/1.369744 · Cited by 72
Ferroelectricity in Pb1+δZrO3 Thin Films
Gao, R., Reyes-Lillo, S. E., Xu, R., Dasgupta, A., Dong, Y., Dedon, L. R., Kim, J., Saremi, S., Chen, Z., Serrao, C. R., et al. (2017) · Chemistry of Materials · doi:10.1021/acs.chemmater.7b02506 · Cited by 54
Metadata
- Authors
- Berlincourt, D.
- Venue
- IEEE Transactions on Sonics and Ultrasonics
- Published
- 1966-10
- Volume
- 13
- Issue
- 4
- Pages
- 116-124
- ISSN
- 0018-9537 (ISSN-L)
- OpenAlex
- W2068209922
- Cited by
- 207
- References
- 5
- FWCI
- 1.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.